We report on the use of a sprayable and thermogelating biomaterial (Poloxamer; a.k.a. Pluronic) in optical imaging of pH values, local oxygen and temperature. The material is highly biocompatible and easy to handle. We also show that the material is well permeable to oxygen (thus making it a good choice for use in oxygen sensors), and is stable in liquid solution and at elevated temperature. We demonstrate its applicability in optical sensors for oxygen, pH and temperature. This was accomplished by incorporating appropriate luminescent probes in various kinds of microparticles (which act as hosts for the probes and prevent dye leaching and aggregation), and then dispersing the microparticles in the thermogelating polymer. The resulting sensor gels were deposited on the surface of interest via spraying at temperatures of <20 °C. At these temperatures, the gels adhere well to the target, even on uneven surfaces such as skin, wounds, and bacterial cultures. If temperature is risen to above 25 °C, the gels form a thin and soft but solid sensing layer which, however, can be simply removed from surface of interest by cooling and wiping it off, or by washing with water. Sprayable thermogelating sensors present obvious advantages over other sensors by not causing damage to the surface of interest. In our perception, the sensing materials also have wide further applicability in sensors for other species including clinically relevant gases, enzyme substrates (such as glucose or lactate) and ions.
A strongly fluorescent organic semiconducting polymer doped with a highly
temperature dependent fluorescent europium(III) complex is converted into a
nanosized material that is capable of optically sensing temperature (T) in the
range from 0 to 50 °C via two-photon excitation at 720 nm. The nanosensors
are prepared from a blue-fluorescent polyfluorene that acts as both a lightharvesting
antenna (to capture two-photon energy) and an energy donor in a
fluorescence resonance energy transfer (FRET) system. The photonic energy
absorbed by the polymer is transferred to the T-sensitive red-luminescent
europium complex contained in the nanoparticles. The close spatial proximity
of the donor and the acceptor warrants efficient FRET. A poly(ethylene glycol)-
co-poly(propylene oxide) block copolymer is also added to render the particles
biocompatible. It is shown that T can be calculated from a) the intensity of
the luminescence of the europium complex, b) the ratio of the intensities of
the red and blue luminescence, or c) the T-dependent luminescence lifetime
of the Eu(III) complex.
The conventional quantitative method for the analysis of inorganic elements in polymer matrices is a complex and time consuming process that presents a significant risk for error. Typically, polymers are digested in a microwave oven or other devices under high temperature and pressure for several hours while employing different mixtures of high purity acids. In many cases, particularly when high concentrations of doped elements are present, the digestion is often incomplete and therefore the reproducibility depends strongly on the type of polymer and additives used. A promising alternative technology that allows for the direct analysis of these polymers without digestion is laser ablation ICP-MS. Due to a lack of available reference materials and the presence of matrix dependent effects, a precise calibration cannot be obtained. In order to compensate for the matrix dependent effects the use of internal standardization is necessary. In this study the correlation between the carbon released during the ablation process and the 13C signal detected by ICP-MS and its use as an internal standard are investigated. For this purpose, twenty-one virgin polymer materials are ablated; the released carbon is determined and correlated with the corresponding integrated 13C signal. The correlation resulted in a direct relationship between the ablated carbon and 13C signal demonstrating the potential ability to neglect at least some of the matrix dependent and transport effects which occur during the laser ablation of virgin polymers.
Bright, long-lived emission from first-row transition-metal complexes is very challenging to achieve. Herein, we present a new strategy relying on the rational tuning of energy levels. With the aid of the large N-Cr-N bite angle of the tridentate ligand ddpd (N,N′-dimethyl-N,N′-dipyridine-2-ylpyridine-2,6-diamine) and its strong σ-donating capabilities, a very large ligand-field splitting could be introduced in the chromium(III) complex [Cr(ddpd)2]3+, that shifts the deactivating and photoreactive 4T2 state well above the emitting 2E state. Prevention of back-intersystem crossing from the 2E to the 4T2 state enables exceptionally high near-infrared phosphorescence quantum yields and lifetimes for this 3d metal complex. The complex [Cr(ddpd)2](BF4)3 is highly water-soluble and very stable towards thermal and photo-induced substitution reactions and can be used for fluorescence intensity- and lifetime-based oxygen sensing in the NIR.