Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (73)
- Beitrag zu einem Tagungsband (21)
- Beitrag zu einem Sammelband (11)
- Sonstiges (5)
- Forschungsbericht (4)
- Vortrag (1)
- Posterpräsentation (1)
- Preprint (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (83)
- Deutsch (34)
- Mehrsprachig (1)
Schlagworte
- Synchrotron (7)
- BAMline (6)
- XRF (6)
- Gefahrgut (5)
- Gefahrstoff (5)
- Prüfmethode (5)
- Qualitätssicherung (5)
- XANES (5)
- Color X-ray camera (4)
- Hazardous substances (4)
Organisationseinheit der BAM
- 6 Materialchemie (17)
- 6.3 Strukturanalytik (15)
- 2 Prozess- und Anlagensicherheit (11)
- 1 Analytische Chemie; Referenzmaterialien (9)
- 2.0 Abteilungsleitung und andere (6)
- 2.1 Sicherheit von Energieträgern (6)
- 7 Bauwerkssicherheit (5)
- 1.4 Prozessanalytik (4)
- 1.5 Proteinanalytik (4)
- 4 Material und Umwelt (4)
Eingeladener Vortrag
- nein (1)
The publicly available document encapsulates the first version of the Catalogue of Services of the future EC4Safenano Centre (CoS 2019).
The CoS 2019 is structured in 12 Service Categories and 27 Service Topics, for each of the 12 categories considered. This architecture configures a 12 x 27 matrix that allows ordering the potential EC4Safenano offer in 324 types of services/groups of services.
Each type of service/group of services is described, in a simple and friendly way, by means of a specific service sheet: the EC4Safenano - Service Data Sheet (EC4-SDS). These EC4-SDSs allow structuring and summarizing the information of each service, providing the customer with a concise view of characteristics of the service and also the contact details with the service provider.
The CoS 2019 deploys a map of services consisting of a set of 100 EC4-SDSs, covering 7 of the 12 Service Categories and 17 of the 27 Service Topics.
The harmonization of services is visualized as a future necessary step in EC4Safenano, in order to strengthen the offer and provide added value to customers with a growing offer of harmonized services in future versions of the CoS.
The information contained in this document is structured in 3 main sections, as follows:
• Catalogue structure. This section describes in short the main characteristics of the CoS 2019.
• Catalogue content. This section represents the core part of the document and encapsulates the set of 100 SDSs displaying the offer proposed by the CoS 2019.
• Online Catalogue. This section describes the resources implemented by EC4Safenano to facilitate the on-line consultation of the CoS 2019 by customers and other interested parties.
Recent DNA-based studies have shown that the built environment is surprisingly rich in fungi. These indoor fungi – whether transient visitors or more persistent residents – may hold clues to the rising levels of human allergies and other medical and building-related health problems observed globally. The taxo¬nomic identity of these fungi is crucial in such pursuits. Molecular identification of the built mycobiome is no trivial undertaking, however, given the large number of unidentified, misidentified, and technically compromised fungal sequences in public sequence databases. In addition, the sequence metadata required to make informed taxonomic decisions – such as country and host/substrate of collection – are often lacking even from reference and ex-type sequences. Here we report on a taxonomic annotation workshop (April 10–11, 2017) organized at the James Hutton Institute/University of Aberdeen (UK) to facilitate reproducible studies of the built mycobiome. The 32 participants went through public fungal ITS bar¬code sequences related to the built mycobiome for taxonomic and nomenclatural correctness, technical quality, and metadata availability. A total of 19,508 changes – including 4,783 name changes, 14,121 metadata annotations, and the removal of 99 technically compromised sequences – were implemented in the UNITE database for molecular identification of fungi (https://unite.ut.ee/) and shared with a range of other databases and downstream resources. Among the genera that saw the largest number of changes were Penicillium, Talaromyces, Cladosporium, Acremonium, and Alternaria, all of them of significant importance in both culture-based and culture-independent surveys of the built environment.
Weltweit werden etwa 80–85 % aller abgebauten Rohphosphate für die Produktion von Düngemitteln verwendet. Bei noch steigendem Bedarf an Phosphor (P) geht man derzeit davon aus, dass die weltweiten P-Reserven noch über 200 Jahre ausreichen. Um den P-Vorrat langfristig abzusichern, sollte der in Reststoffen enthaltene Phosphor möglichst umfänglich genutzt werden. Dieser Forderung trägt das von der Bundesregierung 2012 erstmals beschlossene Deutsche Ressourceneffizienzprogramm ProgRess Rechnung. Rohphosphat wird auch seitens der Europäischen Kommission aufgrundseiner ökonomischen Bedeutung und des unsicheren Angebots als „kritischer Rohstoff“ eingestuft. Vor diesem Hintergrund hat die Bundesregierung in der Verordnung zur Neuordnung der Klärschlammverwertung vom 27. September 2017 in Deutschland eine verpflichtende technische Rückgewinnung von Phosphor für Abwasserbehandlungsanlagen ab einer Ausbaugröße von 100.000 Einwohnerwerten (12 Jahre nach Inkrafttreten der Verordnung) bzw. ab einer Ausbaugröße von über 50.000 Einwohnerwerten (15 Jahre nach Inkrafttreten der Verordnung) vorgeschrieben. Die Verordnung enthält keine Vorgaben hinsichtlich der anzuwendenden Technologie bei der Phosphorrückgewinnung. Ausgenommen von der Rückgewinnungspflicht sind Klärschlämme mit niedrigen Phosphorgehalten (weniger als 20 Gramm Phosphor je Kilogramm Klärschlamm-Trockenmasse). Auch die im Jahre 2017 verabschiedeten neuen Rechtsvorschriften für die Düngung verlangen zukünftig einen nachhaltigen und ressourceneffizienten Umgang mit Nährstoffen bei der landwirtschaftlichen Erzeugung und schränken die P-Zufuhr insbesondere auf hoch versorgten Böden ein (Düngeverordnung vom 26. Mai 2017). Dies wird zu einem mehr am Pflanzenbedarf orientierten und ggf. vermehrt überbetrieblichen Einsatz von wirtschaftseigenen Düngern führen. Um den politischen und gesetzlichen Anforderungen gerecht zu werden, müssen einerseits wirksame und kosteneffiziente technische Verfahren zum P-Recycling (weiter)entwickelt werden. Andererseits müssen die Recyclingprodukte die Anforderungen für eine direkte Verwendung in der Landwirtschaft oder als Rohstoff für die Herstellung von Düngemitteln erfüllen. In dem vorliegenden Standpunkt wird zunächst der potenzielle Beitrag von Reststoffen zur Deckung des P-Bedarfs in der deutschen Pflanzenproduktion geschätzt. Für die wichtigsten Reststoffe werden technische Verfahren zur P-Rückgewinnung bzw. Aufarbeitung skizziert. Auf Basis der Anforderungen der Landwirtschaft bzw. der Düngemittelindustrie
an die P-Recyclingprodukte werden deren Herstellungsverfahren bewertet. Schließlich wird der Regelungs- und Forschungsbedarf formuliert.
Accurate and reliable detection of subsea Pipeline corrosion is required in order to verify the integrity of the pipeline. A laboratory trial was conducted with a representative pipe sample. The accurate measurement of the wall thickness and corrosion was performed with high energy X-rays and a digital detector array. A 7.5 MV betatron was used to penetrate a stepped pipe and a welded test pipe of 3 m length and 327 mm outer diameter, with different artificial corrosion areas in the 24 mm thick steel wall. The radiographs were taken with a 40 x 40 cm² digital detector array, which was not large enough to cover the complete pipe diameter after magnification. A C-arm based geometry was tested to evaluate the potential for automated inspection in field. The primary goal was the accurate measurement of wall thickness conforming to the standard. The same geometry was used to explore the ability of a C-arm based scanner in asymmetric mode for computed tomography (CT) measurement, taking projections covering only two thirds of the pipe diameter. The technique was optimized with the modelling Software aRTist. A full volume of the pipe was reconstructed and the CT data set was used for reverse engineering, providing a CAD file for further aRTist simulations to explore the technique for subsea inspections.
Bright emitters with photoluminescence in the spectral region of 800–1600 nm are increasingly important as optical reporters for molecular imaging, sensing, and telecommunication and as active components in electrooptical and photovoltaic devices. Their rational design is directly linked to suitable methods for the characterization of their signal-relevant properties, especially their photoluminescence quantum yield (Φf). Aiming at the development of bright semiconductor nanocrystals with emission >1000 nm, we designed a new NIR/IR integrating sphere setup for the wavelength region of 600–1600 nm. We assessed the performance of this setup by acquiring the corrected emission spectra and Φf of the organic dyes Itrybe, IR140, and IR26 and several infrared (IR)-emissive Cd1-xHgxTe and PbS semiconductor nanocrystals and comparing them to data obtained with two independently calibrated fluorescence instruments absolutely or relative to previously evaluated reference dyes. Our results highlight special challenges of photoluminescence studies in the IR ranging from solvent absorption to the lack of spectral and intensity standards together with quantum dot-specific challenges like photobrightening and photodarkening and the size-dependent air stability and photostability of differently sized oleate-capped PbS colloids. These effects can be representative of lead chalcogenides. Moreover, we redetermined the Φf of IR26, the most frequently used IR reference dye, to 1.1 × 10-3 in 1,2-dichloroethane DCE with a thorough sample reabsorption and solvent absorption correction. Our results indicate the need for a critical reevaluation of Φf values of IR-emissive nanomaterials and offer guidelines for improved Φf measurements.
Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn:
1. There is a need for improvement and validation for all laboratory test methods examined.
2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification.
This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality.
Die Ursachen für Chemikalienunfälle können vielfältig sein. Prävention beginnt bereits im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse.
Prävention beginnt im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. Bei der Prüfung der gefährlichen Eigenschaften von Chemikalien sind Referenzmaterialen auf Grund der Instabilität in der Regel nicht verfügbar. Für Prüflaboratorien sind RV daher eine Alternative bei der Qualitätssicherung. RV sind jedoch aufwendig und können nur in relativ großen Zeitabständen durchgeführt werden. Es sind deshalb Verfahren zur Verifizierung z. B. der in den Laboratorien verwendeten Prüfapparaturen zu entwickeln. Die Entwicklung von Verifizierungsverfahren wird am Bespiel der Prüfmethode UN Test N.5 demonstriert.
CEQAT-DGHS Interlaboratory Test Programme for Chemical Safety - Need of Test Methods Validation
(2019)
Safety experts, manufacturers, suppliers, importers, employers or consumers must be able to rely on the validity of safety-related test methods and on correct test results and assessments in the laboratory. Via the eChemPortal lots of data from the REACH registration dossiers are available. However, the quality and correctness of the information remains in the responsibility of the data submitter. Unfortunately, we found more or less appropriate information on physicochemical properties and concluded that more quality or adequacy of any data submitted will be needed.
Interlaboratory tests play a decisive role in assessing the reliability of test results. Interlaboratory tests on different test methods have been performed by Bundesanstalt für Materialforschung und –prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB) in collaboration with the QuoData GmbH during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory tests. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method.
In view of the interlaboratory test results the following conclusions can be drawn:
• To avoid any discrepancy on classification and labelling of chemicals it should become state of the art to use validated test methods and the results accompanied by the measurement uncertainty.
• A need for improvement is demonstrated for all examined test methods. Thus, interlaboratory tests shall initially aim at the development, improvement and validation of the test methods and not on proficiency tests.
• The laboratory management and the practical execution of the tests need to be improved in many laboratories.
• The term "experience of the examiner" must be seen critically: A "long experience with many tests" is not necessarily a guarantee for correct results.
DICONDE in der ZfP
(2023)
DICONDE (Digital Imaging and Communication in Non-Destructive Evaluation) ist ein offener internationaler Standard zur Speicherung und zum Austausch industrieller Prüfdaten und prozessbezogener Informationen. Der DICONDE-Standard definiert sowohl die Semantik für eine strukturierte Speicherung von Daten als auch die netzwerkbasierte Kommunikation zwischen zwei Endpunkten. Damit lassen sich viele Vorgänge von Prüfprozessen digital und sicher abbilden und gleichzeitig normative Anforderungen wie eine Rückführbarkeit zum Prüfer und Prüfobjekt sowie eine Reproduzierbarkeit von Prüfergebnissen erfüllen.