Filtern
Erscheinungsjahr
- 2015 (7) (entfernen)
Dokumenttyp
Sprache
- Englisch (5)
- Deutsch (1)
- Mehrsprachig (1)
Schlagworte
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
The awareness of the environmental impact of the building sector is increasing. Steel reinforced concrete is the most commonly used construction material, though with a high-embodied energy and carbon footprint. Large environmental gains may arise if an alternative to steel reinforced concrete is developed. In this context, ultra-high performance concrete (UHPC) materials are shown to be promising alternatives with advantages such as lower embodied energy and reduced environmental impact. Predictions suggest that UHPC composite elements for building envelopes could have other benefits such as an increased service life, optimised use of building area due to thinner elements and minimised maintenance due to the absence of reinforcement or use of non-corrosive reinforcing materials such as carbon fibres. In the framework of the H-HOUSE project funded by the European Commission, composite elements are developed. The aim is to create facade panels combining an autoclaved aerated concrete or cellular lightweight concrete insulation layer with an external UHPC supporting layer. To enhance occupant comfort and health, hygroscopic materials that are capable to buffer indoor air humidity shall be applied to the inside of such elements. Indoor air humidity levels are expected to be more stable, which shall subsequently improve the indoor climate and minimise potential decay to the construction.
The current paper focuses on the determination of reliable numerical models of earth block masonry wallettes under different loading conditions. Uniaxial compression and diagonal compression tests were performed. Experimental behaviour was modelled with a non-linear model able to describe the cracking behaviour. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with high computational cost, represents a suitable tool to predict the masonry collapse mechanism.
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.
ln this paper a modelling approach is presented to reproduce the mechanical behaviour of sandwich panels via finite element analysis. Two types of panels were investigated in this scope of work. The first sandwich element was a textile reinforced concrete (TRC) panel with cellular lightweight concrete insulation and the second configuration was an ultra-high performances concrete (UHPC) panel with aerated autoclaved concrete insulation. The goal was to obtain a reliable numerical strategy that represents a reasonable compromise in terms of sufficient accuracy of the element characteristics and the computational costs. The results show the possibility of describing the composite action in a full sandwich panel. The achieved modelling approach will later be used for the optimization of TRC and UHPC panels in terms of minimizing the thickness, identifying the number and location of connectors, as well as evaluating varying anchorage Systems.
In this paper results of the experimental testing performed on brick masonry and earth block masonry are presented. The paper outlines the development of the testing procedures for two different types of anchors. For this purpose, two experimental campaigns of pull-out tests on masonry corner connections strengthened by metallic rod grouted were carried out. Experimental results proved that the implemented testing procedures are suitable to determine the most recurring failure modes of the anchor pins. Moreover, a procedure is proposed to estimate the capacity of grouted anchor pins based on experimental studies.
Ziel der Untersuchungen war es, das Verhalten von Verpressankern zu analysieren, die üblicherweise zur Verstärkung der Eckverbindung von Mauerwerkswänden eingesetzt werden. Im Fokus der Untersuchungen stand die Leistungsfähigkeit der Ankersysteme mit Bezug auf die Versagensarten und auf dem Traglastvermögen der Anker bei Ankerauszug durch gleichförmige Zugbelastung, die als Vereinfachung für die dynamische Belastung durch ein Erdbeben aufgebracht wurde. Die hier dargestellten Untersuchungen und Ergebnisse stellen eine Zusammenfassung von Arbeiten dar, über die bereits in Beiträgen berichtet wurde, die zum einen die Prüfverfahren für verstärkte Eckverbindungen von Gebäuden aus Mauerwerk und zum anderen die Verbundfestigkeit von Verpressankern in Wänden aus verschiedenen Lehmbautechniken zum Inhalt hatten. Sie geben dennoch einen Überblick über die Hauptversagensmechanismen von Verpressankersystemen und erweitern den Wissensstand bezüglich der Prüfung von Ankersystemen für Ziegel- und Lehmsteinmauerwerk. Darüber hinaus wird eine Vorgehensweise vorgeschlagen, die es ermöglicht, die Traglast von Verpressankern auf Basis experimenteller Untersuchungen abzuschätzen.