Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (23)
- Beitrag zu einem Sammelband (2)
- Buchkapitel (1)
- Forschungsbericht (1)
Schlagworte
- Epoxy resin (4)
- Fire retardancy (3)
- Flame retardance (3)
- Fluorescence (3)
- Calibration (2)
- Composites (2)
- DOPO (2)
- Endocrine disruption (2)
- Flow cytometry (2)
- Fracture toughness (2)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
A novel fluorescent host-guest material, molecular sieves of AlPO4-5-type doped with 2,2'-bipyridyl-3,3'-diol, was prepared and spectroscopically characterized. The composite crystals show a pronounced optical anisotropy, indicating a high degree of alignment of the guest molecules within the zeolitic pore system. A mean tilting angle of 22 was found for the orientation of the individual dye molecules in the straight channels. The corrected fluorescence emission spectra were determined, and time-resolved fluorescence studies revealed that the dye molecules are preferentially found in three different types of microenvironment. By invoking pH-dependent studies of the dye in aqueous solution, we could trace these spectroscopic features back to two main influences, coadsorbed water within AlPO4-5 pores and guest-host interactions with a few relatively weak Brnsted acid (defect) sites of the inorganic host network.
The scope of this paper is to illustrate the need for an improved quality assurance in fluorometry. For this purpose, instrumental sources of error and their influences on the reliability and comparability of fluorescence data are highlighted for frequently used photoluminescence techniques ranging from conventional macro- and microfluorometry over fluorescence microscopy and flow cytometry to microarray technology as well as in vivo fluorescence imaging. Particularly, the need for and requirements on fluorescence standards for the characterization and performance validation of fluorescence instruments, to enhance the comparability of fluorescence data, and to enable quantitative fluorescence analysis are discussed. Special emphasis is dedicated to spectral fluorescence standards and fluorescence intensity standards.
Objective: The utilization of fluorescein-guided biopsies and resection has been recently discussed as a suitable strategy to improve and expedite operative techniques for the resection of central nervous system (CNS) tumors. However, little is known about the optical properties of sodium fluorescein (NaFl) in human tumor tissue and their potential impact on ex vivo analyses involving fluorescence-based methods.
Methods: Tumor tissue was obtained from a study cohort of an observational study on the utilization of fluorescein-guided biopsy and resection (n=5). The optical properties of fluorescein-stained tissue were compared to the optical features of the dye in vitro and in control samples consisting of tumor tissue of high-grade glioma patients (n=3) without intravenous (i.v.) application of NaFl. The dye-exposed tumor tissues were used for optical measurements to confirm the detectability of NaFl emission ex vivo. The tissue samples were fixed in 4%PFA, immersed in 30% sucrose, embedded in Tissue-Tek OCT compound, and cut to 10 mm cryosections. Spatially resolved emission spectra from tumor samples were recorded on representative slides with a Confocal Laser Scanning Microscope FV1000 (Olympus GmbH, Hamburg, Germany) upon excitation with lexc = 488 nm.
Results: Optical measurements of fluorescein in 0.9% sodium chloride (NaCl) under in vitro conditions showed an absorption maximum of lmax abs = 479 nm as detected with spectrophotometer Specord 200 and an emission peak at lmax em = 538 nm recorded with the emCCD detection system of a custom-made microscope-based single particle setup using a 500 nm long-pass filter. Further measurements revealed pH- and concentration-dependent emission spectra of NaFl. Under ex vivo conditions, confocal laser scanning microscopy of fluorescein tumor samples revealed a slight bathochromic shift and a broadening of the emission band.
Conclusion: Tumor uptake of NaFl leads to changes in the optical properties – a bathochromic shift and broadening of the emission band – possibly caused by the dye’s high pH sensitivity and concentration-dependent reabsorption acting as an innerfilter of the dye’s emission, particularly in the short wavelength region of the Emission spectrum where absorption and fluorescence overlap. Understanding the ex vivo optical properties of fluorescein is crucial for testing and validating its further applicability as an optical probe for intravital microscopy, immunofluorescence localization studies, and flow cytometry analysis.
Slow burst testing of samples as a method for quantification of composite cylinder degradation
(2014)
The current practise to focus periodic retesting of composite cylinders primarily on the hydraulic pressure test has to be evaluated as critical. The test itself always causes a certain amount of micro damage to the cylinders but does not necessarily deliver sufficient and evaluable information. Thus BAM Federal Institute of Materials Research and Testing (Germany) moves the focal point to a new approach for validation of composite cylinders, based on destructive sample tests parallel to operation. Statistical assessment of results of these destructive tests is employed for the estimation of remaining safe service life, based on reliability demands. The estimated service life is also used for the determination of re-test periods of the examined population of composite cylinders.
An essential aspect of this approach is the validation of current residual strength and its prediction at any point of service life. In cases of gas cylinders with very high cycle strength, residual strength cannot be quantified statistically by means of hydraulic load cycles. As a replacement, creep tests or burst tests may be employed. BAM suggests the 'slow burst test SBT' as a combination of these two test procedures. This is a compromise between the practicability of the (conventional) burst test and the practical relevance of sustained loads during service, to be tested in creep rupture tests. In this paper, a variety of 99 burst results of a cylinder design type used for breathing apparatus (CFRP with PE-liner) is evaluated. The influence of test procedure parameters and nature and intensity of artificial ageing on the test sample strength are analysed statistically. This leads to an evaluation of different procedures of artificial ageing and the recommendation to substitute conventional burst tests by slow burst tests for the assessment of composite pressure receptacles.