Within the National Metrology Institutes (NMIs) and designated laboratories, an interlaboratory comparison, CCQM-P107, was conducted to verify the degree of international comparability concerning the results of purity analysis. The mass fractions of Ag, Bi, Cd, Cr, Ni, Tl at the lower mg/kg-level in a high purity zinc material were determined, but the real measurand in metrological sense was the sum of the six mass fractions. Homogeneity was investigated by glow discharge mass spectrometry, reference values were obtained using isotope dilution mass spectrometry. Six NMIs participated, contributing eight independent data sets. The agreement amongst the results of the participants, their median and the agreement with the reference values were usually excellent and in almost all cases below the target uncertainty of 30% relative. In this manner, the accuracy of results and the comparability between the participants was demonstrated to be established.
The Bundesanstalt für Materialforschung und -prüfung (Federal Institute for Materials Research and Testing) (BAM) is establishing a system of primary reference materials to meet the demands for metrological traceability and to act as national standards in the field of elemental analysis. For all elements of the periodic table - except those that are gases or radioactive - two different kinds of reference materials are being certified. One is for analyte calibration (Type A) and one for problems concerning matrix matching (Type B). These substances are of very high purity and of defined stoichiometry. As far as possible, pure elements and metals rather than pure compounds are used. The certification of both types of material requires most elements of the periodic table to be certified at very low levels using trace element analysis methods. The application of these methods is described and examples of the certification of copper and iron are given.
The Bundesanstalt fuer Materialforschung und -pruefung, BAM (Federal Institute for Materials Research and Testing) continues to establish a system of primary reference materials to meet the demands of metrological traceability. The materials act as national standards in the field of elemental analysis. For all elements of the periodic table -excepting those that are gases or radioactive- two different kinds of reference materials are being certified. The substances are of very high purity and of defined stoichiometry. Pure elements and metals are used as far as possible. They are certified by determining the trace contents of most elements of the periodic table at very low levels using different trace element analysis methods. Recent application of these methods is described and examples of the certification of some pure metals (copper, iron and lead) are given. (author abst.)