- Electron microscopy (2)
- Elektrochemische Verfahren (2)
- Instandsetzung (2)
- Kathodischer Korrosionsschutz (2)
- Korrosion (2)
- Lochkorrosion (2)
- Stahlbeton (2)
- 3-Punkt-Biege-Großprobe (1)
- Betonbrechsand (1)
- Blood-brain barrier (1)
Organisationseinheit der BAM
This paper presents the results of an interlaboratory study of the rheological properties of cement paste and ultrasound gel as reference substance. The goal was to quantify the comparability and reproducibility of measurements of the Bingham parameters yield stress and plastic viscosity when measured on one specific paste composition and one particular ultrasound gel in different laboratories using different rheometers and measurement geometries.
The procedures for both in preparing the cement paste and carrying out the rheological measurements on cement paste and ultrasound gel were carefully defined for all of the study’s participants. Different conversion schemes for comparing the results obtained with the different measurement setups are presented here and critically discussed. The procedure proposed in this paper ensured a reasonable comparability of the results with a coefficient of variation for the yield stress of 27% and for the plastic viscosity of 24%, despite the individual measurement series’ having been performed in different labs with different rheometers and measurement geometries.
Transmission electron microscopy study of rapid thermally annealed Pd/Ge contacts on IN0.53Ga0.47As
(1996)
Die Instandsetzung von Stahlbetonbauteilen bzw.-werken, welche durch chloridinduzierte Korrosion der Bewehrung gefährdet oder bereits geschädigt sind, hat in den letzten Jahrzehnten weltweit an Bedeutung gewonnen. Der kathodische Korrosionsschutz, als elektrochemisches Instandsetzungsverfahren, bildet in diesem Fall eine zuverlässige und oftmals kostengünstige Methode zur Instandsetzung. Am Beispiel des Parkhauses Am Gericht in Frankfurt am Main werden die Durchführung solch einer Maßnahme sowie die Besonderheiten des Verfahrens beschrieben. Es werden die theoretischen Hintergründe erläutert und die praktische Umsetzung sowie zu klärende Detailfragen beschrieben. Die Daten der ersten Depolarisationsmessungen zeigen den aktuellen Zustand der Anlage sowie des Schutzobjektes.
Parkhaus "Am Gericht" in Frankfurt am Main - Eine Sanierung mit kathodischem Korrosionsschutz
(2007)
Parkhäuser haben nach mehreren Jahrzehnten der Nutzung häufig Sanierungsbedarf in Bezug auf die tragende Stahlbetonkonstruktion, die durch eingedrungene Chloride aus eingeschlepptem Tausalz und die hierdurch hervorgerufene Korrosion der Bewehrung in der Tragfähigkeit erheblich beeinträchtigt sein kann. Das Verfahren des kathodischen Korrosionsschutzes kann hier als elektrochemisches Instandsetzungsverfahren eine wirtschaftliche und zuverlässige Alternative zu herkömmlichen Sanierungsverfahren bieten. Voraussetzungen sind intensive Voruntersuchungen, die Kenntnis der sinnvollen Anwendungsgrenzen des Systems, eine qualitativ hochwertige bauliche Umsetzung des Systems und die Nutzung der Möglichkeiten der Überwachung des Instandsetzungserfolges durch Monitoring, was am Beispiel des Parkhauses Am Gericht in Frankfurt am Main erläutert wird.
Parking garage Am Gericht in Frankfurt am Main - a refurbishment with cathodic corrosion protection.
After several decades in use a refurbishment is often necessary for the bearing structure of reinforced concrete parking garages due to chlorides, which have been brought into concrete by road salt, and the resulting corrosion of the reinforcement, which may lead to a serious decrease of the bearing capacity. With the system of the cathodic protection of the reinforcement exists a cost-effective and reliable technique as an alternative to common solutions. An intensive investigation of the structure, the knowledge of the reasonable limits of the system, excellent design and execution of the construction work and the monitoring of the working system are nevertheless required, which is illustrated by the example of the parking garage Am Gericht in Frankfurt am Main.
Transmission electron microscopy study of rapid thermally annealed Pd/Ge contacts on In0.53Ga0.47As
(1996)
Phase formation in rapid thermally annealed Pd/Ge contacts on In0.53Ga0.47As has been investigated by means of cross-sectional transmission electron microscopy, convergent-beam electron diffraction, and energy-dispersive x-ray analysis. Solid-phase regrowth is observed to occur similarly as in Pd/Ge contacts on GaAs or InP. The reaction starts at low temperatures with the formation of an amorphous Pd–In–Ga–As layer, which crystallizes at elevated temperatures yielding hexagonal Pd4In0.53Ga0.47As being first described in this work. At temperatures .250 °C, this phase decomposes due to epitaxial solid-phase regrowth of In0.53Ga0.47As and formation of Pd–Ge phases. The stable composition is reached at temperatures .350 °C with excess Ge diffused through top Pd–Ge to the contact interface and growing epitaxially on the semiconductor.
Platinum does not form any adherent oxides and can be easily wetted by tin-based solders. Platinum is also an available metallization in semiconductor laboratories. Therefore we investigated the diffusion of platinum thin-film metallizations into eutectic tin–lead solder by using a high-resolution secondary ion mass spectroscopy (SIMS) profiling from the back side. It is shown that an intermetallic phase (PtSn4) is formed during soldering, which controls the consumption of platinum during soldering and in operation. The consumption of platinum follows the well-known parabolic diffusion law. The activation energy of this process is 0.63 eV. Even at extended heating cycles of 2 min at 250°C, 190 nm from the original 300 nm of the platinum film remain undissolved. This high stability makes platinum a very attractive thin-film metallization for flip-chip (FC) bonding of new microsystems.
Metformin is widely used as a first-line treatment for type 2 diabetes, but central effects of metformin have received little attention. When metformin (200 mg/kg i.p.) was administered to C57Bl6 mice, metformin concentration in cerebrospinal fluid peaked at 29 μM after 30 min but dropped quickly and was low at 90 min. In mouse hypothalamus sampled by microdialysis, systemically administered metformin caused minor and transient increases of acetylcholine, glucose and lactate while choline levels decreased. When metformin (0.2−10 mM) was locally infused via retrodialysis, there was a short-lasting increase of acetylcholine in the hypothalamus. Extracellular lactate levels in hypothalamus showed a massive increase upon metformin infusion while glucose levels decreased. In isolated mitochondria of mouse brain, metformin inhibited oxygen consumption and the activity of complex I. Inhibition of mitochondrial respiration likely explains lactate formation in the brain during metformin infusion which may cause lactic acidosis during metformin intoxication. The changes of cholinergic activity in the hypothalamus may be associated with appetite suppression observed during metformin treatment.
The study described in this paper was conducted in the framework of the European nPSize project (EMPIR program) with the main objective of proposing new reference certified nanomaterials for the market in order to improve the reliability and traceability of nanoparticle size measurements. For this purpose, bimodal populations as well as complexly shaped nanoparticles (bipyramids, cubes, and rods) were synthesized. An inter-laboratory comparison was organized for comparing the size measurements of the selected nanoparticle samples performed with electron microscopy (TEM, SEM, and TSEM), scanning probe microscopy (AFM), or small-angle X-ray scattering (SAXS). The results demonstrate good consistency of the measured size by the different techniques in cases where special care was taken for sample preparation, instrument calibration, and the clear definition of the measurand. For each characterization method, the calibration process is described and a semi-quantitative table grouping the main error sources is proposed for estimating the uncertainties associated with the measurements. Regarding microscopy-based techniques applied to complexly shaped nanoparticles, data dispersion can be observed when the size measurements are affected by the orientation of the nanoparticles on the substrate. For the most complex materials, hybrid approaches combining several complementary techniques were tested, with the outcome being that the reliability of the size results was improved.