One essential step on the way towards accurate quantitative simulation of radiographic testing is an accurate description of the utilized energy spectrum of X-ray photons. For use in general purpose simulation tools, the spectra of X-ray tubes have to be described by a model covering at least the intended range of applications. This range includes transmission tubes as well as direct beam tubes with varying angles of incidence and emission, for a number of typical target materials. In radiographic testing acceleration voltages frequently reach up to 450 kV for direct beam targets and up to 225 kV for transmission targets, with even higher voltages available or being developed. Currently used models are unable to cover the whole range of configurations.
Here a model is presented that employs a unified approach for simulating the photon energy spectra for transmission and direct beam targets composed of arbi-trary homogeneous materials. In order to achieve this, a detailed model of electron transport within the target is employed. The validity of the developed model is shown through comparisons with Monte Carlo simulations as well as measurements for a number of different configurations.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we Focus on Monte Carlo Simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications.
X-ray backscatter imaging is a well established NDT technique to inspect complex objects using only a single-sided access. In difference to conventional transmission X-ray radiography, the X-ray backscatter imaging utilizes the scattered radiation caused by the Compton scattering effect. In order to achieve high backscatter intensities from a test object, it is necessary to optimize the backscatter system parameters namely the angle between source and slit camera, the slit collimator system, the shielding between source and scatter camera, and the type of detector. In addition, the scatter phenomena in to the investigated object need to be understood.
In this contribution, we present a Monte Carlo model McRay which considers all relevant single and multiple interactions of photons and electrons. This model can be used to simulate back scatter techniques. It allows not only calculating the scatter image for a given experimental setup but also registering the spectrum of the detected scattered photons. Both aspects are important to understand the imaging process, to interpret the results, and to optimize the backscatter camera investigated here. Additionally experimental results will be presented and compared with simulations.
X-ray backscatter imaging is a well established NDT technique to inspect complex objects using only a single-sided access. In difference to conventional transmission X-ray radiography, the X-ray backscatter imaging utilizes the scattered radiation caused by the Compton scattering effect. In order to achieve high backscatter intensities from a test object, it is necessary to optimize the backscatter system parameters namely the angle between source and slit camera, the slit collimator system, the shielding between source and scatter camera, and the type of detector. In addition, the scatter phenomena in to the investigated object need to be understood.
In this contribution, we present a Monte Carlo model McRay which considers all relevant single and multiple interactions of photons and electrons. This model can be used to simulate back scatter techniques. It allows not only calculating the scatter image for a given experimental setup but also registering the spectrum of the detected scattered photons. Both aspects are important to understand the imaging process, to interpret the results, and to optimize the backscatter camera investigated here. Additionally experimental results will be presented and compared with simulations.
In this contribution, we discuss the influence of scattered radiation on materials’ effective attenuation coefficients at higher X-ray energies. The selected X-ray spectra for the dual-energy experiments correspond to 3 MV and 7.5 MV acceleration potential of the used betatron. Experiments were performed on a test phantom containing step wedges of different low- and high-Z materials. We evaluated the ratio between low- and high-energy X-ray attenuation coefficients quantitatively based on simulated poly-energetic high-energy X-ray source spectra and the detector sensitivity using the “analytical Radiographic Testing inspection simulation tool” (aRTist) developed at BAM. Furthermore, the influence of scattered radiation is evaluated using an efficient Monte-Carlo simulation. The simulation results are compared quantitatively with experimental investigations. Finally, important applications of the proposed technique in the context of aviation security are discussed.
Modeling of the photon-electron cascade process in multicomponent objects of complex geometrical structure by use of hybrid supercomputers is considered. An approach to computing the cascade processes is developed. The approach has three key properties allowing the effective use of heterogeneous structure of computers for solving the tasks of radiation transport in complex multi-scale geometries. Firstly, two different discreet geometrical description of an object being under radiation is used: triangulated model for photon transport and voxel model for elec-tron transport. Secondly, small parameter of the problem is explicitly taking into ac-count for modeling surface effects (for instance, electron emission). Thirdly, the ef-fective calculation decomposition between CPU and GPU is developed for signifi-cant increasing the speed of calculations of processes in question. Modeling of ex-periment on researching the bremsstrahlung generated by electron beam in Ta target is carried out. Comparison of computing and experimental results shows satisfactory consent.
Computer modelling of non-destructive testing methods has come a long
way from the beginnings in the mid 90s to today. Radiographic modelling for
components with higher wall thicknesses, as they are typical for nuclear
applications, must include precise predictions of scattered radiation and its impact
in terms of contrast reduction. Dedicated or general purpose Monte Carlo methods
with the ability to calculate higher order scattering events are the state of the art for
these applications. Aerospace applications, on the other hand, have stronger
requirements on the modelling code's capabilities to import complex CAD
geometries, and can benefit from faster analytical scatter models, limited to first or
second order scattering events. Similar distinctions can be made for the various
approaches proposed to accurately model geometrical and film unsharpness, film
granularity, film responses, film/foil cartridges and photon noise. This article
presents a state-of-the-art review of radiographic modelling from the perspective of
two important application domains with very different requirements, nuclear and
aerospace.
A fast quantitative model for the energy spectra of radiation emitted by X-ray tubes is described, handling thin as well as thick plane targets of arbitrary materials. The developed model is based on fundamental interaction cross sections, describing electron and photon transport via numerical integration of discretized distributions. While the focus lies on bremsstrahlung production, modeling of characteristic radiation is fully integrated. The model does not include any free parameters. The validity of the model is shown through comparison with measurements and Monte Carlo simulations for several combinations of target material and acceleration potential between 30 kV and 450 kV.
Rare events are understood to be events occurring once in a while but with dramatic consequences. Their occurrence cannot be predicted precisely, only a probability might be estimated, for example from past experiences. However, it might be rather misleading to attempt to describe them by distribution curves that apply for frequent or repeated observations, such as the Gaussian bell shape. Alternative distributions have been introduced to characterise the intervals at which a certain event may occur. It is the aim of technical safety and public security to prevent adverse events. Detectable indications that are typical for their course and are observable have to be identified before an incident occurs. Since they should be characteristic for such cases, they themselves also constitute rare events. The problem encountered in any detection system is that nothing is perfect. As in medical diagnostics, true indications may be missed or false test responses may pretend to be something that does not exist. Balancing missed indications with false positive calls is achieved with the aid of the so-called receiver operating characteristics (ROC). However, with the aid of Bayes’ inference it can be shown that identifying signs of a rarely occurring indication is like looking for a needle in a haystack, even with an excellent detection Approach with a low miss rate and an even lower probability of false calls. The inclusion of additionally available information may lead to a more effective search strategy. When employing imaging methods for detecting flaws or illicit items, the identification of rare indications can be impeded by blurring noise or overlapping items. The identification of the features sought can be supported by including information on their typical characteristics
by regularisation algorithms. The strategy of such an approach is demonstrated in a simplified example with a plain geometric figure (circle) corrupted with structural noise. The shape of the original figure was clearly recovered. In general, search strategies should aim at an indication typical for the event to be prevented; otherwise, alternative approaches have to be considered, including, perhaps, serendipity.
The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography
reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.