Numerical Simulation of X-Ray Scattering Processes during Radiographic Inspection of Materials
(2006)
Abstract A technique for numerical simulation of the processes of forming X-ray radiography images of complex multicomponent objects with allowance for the penetrating-radiation absorption and scattering processes is proposed. The technique proposed is based on an efficient description of complex 3D objects with piecewise-homogeneous structures and uses precisely specified shells separating homogeneous components of an object. Being combined with a developed version of the Monte Carlo method, this approach yields an efficient computational apparatus for analyzing the regularities of the formation of radiographic images of objects internal structures. This apparatus is intended for state-of-the-art multiprocessor computing systems. Having been obtained via the technique developed, the results of the numerical analysis of the effect of different mechanisms of interaction between photons and matter (including coherent and incoherent scattering with allowance for bonds of electrons in atoms) on the formed radiographic image of the objects internal structure are discussed. The advantage of the described technique over the known MCNP program complex is shown.
Statistical algorithms are presented for modeling the interaction processes between electrons and matter. A software
implementation has been developed for hybrid supercomputers making use of NVIDIA© CUDA©
technology. Standard Monte Carlo schemes are modified for effectively exploiting the parallel computing capabilities
of graphical processors. The model of individual collisions (MIC) is used to describe the interaction of
electrons with atoms. This model does not include the approximations assumed in multiple collision theory or
the continuous slow down approach with the Landau theory for energy-loss fluctuations. The distributions of
electron characteristics are obtained from tabulated electron cross section data. The examples discussed in this
paper demonstrate the applicability of the algorithms to investigating the interaction of electrons with X-ray tube
targets producing Bremsstrahlung. The proposed technique can be used for mathematical modeling in radiography.
An approach is presented to construct operators for transforming the characteristics of incident radiation to transmitted radiation, as well as operators for transforming the transmitted radiation to measured values. Simu-lating the radiation transport is based on Monte Carlo modeling of the interaction of X-ray photons and electrons with matter. The proposed method permits to construct, for instance, the operator connecting the initial radiation spectrum with the absorbed photon energy penetrating a given object. The elaborated approach provides the possibility of effective mathematical modeling of radiation techniques such as radiography, treating complex multi-component objects. Moreover, the method can be used to construct the operator equation for solving in-verse problems, e.g. the reconstruction of the initial radiation spectrum using simple experimental measure-ments. Comparison with some experimental measurements is presented.
A special slit collimator was developed earlier for fast acquisition of X-ray back scatter images. The design was based on a twisted slit design (ruled surfaces) in a Tungsten block to acquire backscatter images. The comparison with alternative techniques as flying spot and coded aperture pin hole technique could not prove the expected higher contrast sensitivity. In analogy to the coded aperture technique, a novel multi slit camera was designed and tested. Several twisted slits were parallelly arranged in a metal block. The CAD design of different multi-slit cameras was evaluated and optimized by the computer simulation packages aRTist and McRay. The camera projects a set of equal images, one per slit, to the digital detector array, which are overlaying each other. Afterwards, the aperture is corrected based on a deconvolution algorithm to focus the overlaying projections into a single representation of the object. Furthermore, a correction of the geometrical distortions due to the slit geometry is performed. The expected increase of the contrast-to-noise ratio is proportional to the square root of the number of parallel slits in the camera. However, additional noise has to be considered originating from the deconvolution operation. The slit design, functional principle, and the expected limits of this technique are discussed.
Computer modelling of non-destructive testing methods has come a long
way from the beginnings in the mid 90s to today. Radiographic modelling for
components with higher wall thicknesses, as they are typical for nuclear
applications, must include precise predictions of scattered radiation and its impact
in terms of contrast reduction. Dedicated or general purpose Monte Carlo methods
with the ability to calculate higher order scattering events are the state of the art for
these applications. Aerospace applications, on the other hand, have stronger
requirements on the modelling code's capabilities to import complex CAD
geometries, and can benefit from faster analytical scatter models, limited to first or
second order scattering events. Similar distinctions can be made for the various
approaches proposed to accurately model geometrical and film unsharpness, film
granularity, film responses, film/foil cartridges and photon noise. This article
presents a state-of-the-art review of radiographic modelling from the perspective of
two important application domains with very different requirements, nuclear and
aerospace.
Im Rahmen des EMPIR-Projektes NanoXSpot (Nanometre X-Ray Focal Spot Measurement) werden rückführbare Messverfahren zur Bestimmung der Brennfleckgröße und -form von Röntgenröhren mit Submikrometerauflösung (100 nm – 20 μm) entwickelt, die die Grundlage für die Erarbeitung eines Standardentwurfes bilden. Der Standardentwurf wird bei CEN TC 138 (Non-destructive testing) WG 1 (Radiographic testing) eingereicht und mit ISO und ASTM harmonisiert. Zur Untersuchung der entwickelten Methoden (Brennfleck-CT, Fit-Prozedur für Strichgruppenkörper) und des im Projekt NanoXSpot neu entworfenen Testkörpers, NxS, wurde ein Ringversuch durchgeführt. Dabei wurde sowohl der angestrebte Überlappungsbereich mit EN 12543 Teil 5 (Messung der effektiven Brennfleckgröße von Mini- und Mikrofokus-Röntgenröhren) und ASTM E 2903 (Standard Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes) für Brennflecke >5 μm als auch Brennflecke <5 μm untersucht. Im Mittelpunkt standen dabei Stabilität und Wiederholbarkeit der entwickelten Methoden zur Bestimmung der Brennfleckgröße. In diesem Beitrag werden die Ergebnisse des durchgeführten Ringversuches vorgestellt und diskutiert, um Schlussfolgerungen und Empfehlungen für die Vorbereitung eines erweiterten Ringversuchs mit Partnern und Stakeholdern abzuleiten.