Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (53)
- Beitrag zu einem Tagungsband (27)
- Beitrag zu einem Sammelband (5)
- Posterpräsentation (5)
- Buchkapitel (2)
- Vortrag (2)
- Forschungsbericht (2)
- Sonstiges (1)
Sprache
- Englisch (71)
- Deutsch (25)
- Mehrsprachig (1)
Schlagworte
- KorroPad (7)
- EPR (6)
- Wärmebehandlung (6)
- Corrosion resistance (5)
- Korrosion (5)
- Nichtrostender Stahl (5)
- ThermoCalc (5)
- XPS (5)
- EBSD (3)
- Glass (3)
Organisationseinheit der BAM
- 6 Materialchemie (9)
- 6.1 Oberflächen- und Dünnschichtanalyse (6)
- 5 Werkstofftechnik (5)
- 5.6 Glas (5)
- 7 Bauwerkssicherheit (5)
- 7.6 Korrosion und Korrosionsschutz (4)
- 8 Zerstörungsfreie Prüfung (4)
- 6.2 Material- und Oberflächentechnologien (3)
- 8.5 Röntgenbildgebung (2)
- 2 Prozess- und Anlagensicherheit (1)
- 2.1 Sicherheit von Energieträgern (1)
- 4 Material und Umwelt (1)
- 4.3 Schadstofftransfer und Umwelttechnologien (1)
- 5.3 Polymere Verbundwerkstoffe (1)
- 6.6 Physik und chemische Analytik der Polymere (1)
- 7.2 Ingenieurbau (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
- 9 Komponentensicherheit (1)
- 9.5 Tribologie und Verschleißschutz (1)
Eingeladener Vortrag
- nein (2)
The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits.
There is a strong need for cost-effective mitigation measures for
turnouts. SBB has initiated a series of examinations using different methodologies to gain a deeper understanding of the excitation mechanisms at low frequencies, in addition to that obtained in the RIVAS project. To date it is not yet clear what constitutes a complete measurement data set that would enable understanding most of the vibration excitation mechanisms in turnouts. Increasing vibration at turnouts in comparison to normal track is observed for all measured frequencies.
The different methodologies are presented in the paper. Under-sleeper pads (USP) are a cost-effective method to reduce vibration at frequencies above 63 Hz (1/3 octave), but there is probably no improvement for frequencies below 63 Hz. A first test of new frog geometry did not show relevant improvements in Vibration emission in comparison to a reference frog geometry. Axle box acceleration measurements are an interesting method to identify defects in a turnout. A specialized measurement system of rail roughness could identify certain geometry Problem areas for some frogs. Noise increases also are observed at turnouts for frequencies ranging between 80 to 1000 Hz. The use of railway source models to calculate
contact forces for ballasted track and turnouts seems promising, in particular for understanding the influence of ground.
Glass-ceramics containing Ca2KNa(PO4)2 as the main crystalline phase have a solubility which is 8 times higher than that of alpha-tricalcium phosphate ceramics. When using these compositions in drug delivery systems, especially in bone, it is necessary to create a material with a high open porosity. A Ca2KNa(PO4)2-based glass-ceramic was prepared from a borosilicate glass melt. The processed material includes minor amounts of boron which are low enough for medical application. Tissue response was studied using an animal model. Particles were implanted in rabbit femurs. Bone and soft tissue development occurred at the particle interfaces. In general, most particles were enclosed in the network of trabecular bone. The advantages of using a biomaterial with high porosity (pore size of 1-3 micron), together with rapid biodegradation, bioactivity and biocompatibility, despite traces of boron, were shown. 4 refs.
Results are reported from a pilot study under the Consultative Committee for Amount of Substance (CCQM) to compare measurements of and resolve any relevant measurement issues in, the amount of thermal SiO2 oxide on (100) and (111) orientation Si wafer substrates in the thickness range 1.5 - 8 nm. As a result of the invitation to participate in this activity, 45 sets of measurements have been made in different laboratories using 10 analytical methods: medium-energy ion scattering spectrometry (MEIS), nuclear reaction analysis (NRA), RBS, elastic backscattering spectrometry (EBS), XPS, SIMS, ellipsometry, grazing-incidence x-ray reflectrometry (GIXRR), neutron reflectometry and transmission electron microscopy (TEM). The measurements are made on separate sets of 10 carefully prepared samples, all of which have been characterised by a combination of ellipsometry and XPS using carefully established reference conditions and reference parameters.
The results have been assessed against the National Physical Laboratory (NPL) data and all show excellent linearity. The remaining data sets correlate with the NPL data with average root-mean-square scatters of 0.15 nm, half being better than 0.1 nm and a few at or better than 0.05 nm. Each set of data allows a relative scaling constant and a zero thickness offset to be determined. Each method has an inherent zero thickness offset between 0 nm and 1 nm and it is these offsets, measured here for the first time, that have caused many problems in the past. There are three basic classes of offset: water and carbonadeous contamination equivalent to ~1 nm as seen by ellipsometry; adsorbed oxygen mainly from water at an equivalent thickness of 0.5 nm as seen by MEIS, NRA, RBS and possibly GIXRR; and no offset as seen by XPS using the Si 2p peaks. Each technique has a different uncertainty for the scaling constant and consistent results have been achieved. X-Ray photoelectron spectroscopy has large uncertainties for the scaling constant but a high precision and, critically, if used correctly, has zero offset. Thus, a combination of XPS and the other methods allows the XPS scaling constant to be determined with low uncertainty, traceable via the other methods. XPS laboratories returning results early were invited to test a new reference procedure. All showed very significant improvements. The reference attenuation lengths thus need scaling by 0.986 ± 0.009 (at an expansion factor of 2) deduced from the data for the other methods. Several other methods have small offsets and, to the extent that these can be shown to be constant or measurable, then these methods will also show low uncertainty. Recommendations are provided for parameters for XPS, MEIS, RBS and NRA to improve their accuracy.
Bone development and bone structure depend on surface roughness and structure of metalic implants
(2000)