Best energy selection for different applications with digital detector arrays from 20 to 600 keV
(2012)
New Digital Radiography Procedure Exceeds Film Sensitivity Considerably in Aerospace Applications
(2006)
Einfluss von Metall-Speicherfolien-Kombinationen auf die Bildqualität in der Computer-Radiographie
(2008)
Bei der Normgestaltung für Speicherfolien sind die Auswirkungen von Metallfolien und Metallfolienkombinationen auf die Bildqualität von Speicher-folienaufnahmen nicht ausreichend berücksichtigt worden. Es ist bekannt, dass bei Film - Metallfolien - Kombinationen zusätzlich zur Änderung der optischen Dichte und der Filmgranularität auch Änderungen der inneren Unschärfe durch den seitli-chen Energietransport in der Film Metallfolien - Kombination entstehen, welche überwiegend durch ausgelöste Elektronen und zum Teil durch sekundäre Strahlung hervorgerufen werden. Gleichzeitig dienen die Metallfolien bei Röntgenaufnahmen mit Film als Streustrahlfilter und können zur Verbesserung des Bildkontrastes bei-tragen. Die Mechanismen zur Erzeugung des virtuellen Röntgenbildes und dessen Visualisierung sind in Speicherfolien nicht mit denen in einem Röntgenfilm iden-tisch. Demzufolge können die in den Normen festgelegten Vorschriften zum Einsatz von Metallfolien in der Filmradiographie nicht auf Speicherfolien uneingeschränkt übertragen werden. Anhand der hier erzielten Ergebnisse lassen sich Empfehlungen zum zukünftigen Einsatz der Metallfilter und -folienkombinationen für die Speicher-folientechnik zur Verbesserung der Bildgüte ableiten.
Different girth welds of tube sections have been inspected by elliptical projection technique
according to the EN 1435. The radiographic images were taken by using both film
radiography and computed radiography. The purpose of this study was to compare a C3
(AGFA D4) film system and a Duerr HDCR 35 NDT / HR IP imaging plate system with
respect to the exposure time, image quality and the detection of fine weld imperfections. The
results indicate to a dominant influence of the lead screens on the image contrast sensitivity if
doing the inspection according to the EN 14748 -2 for imaging plate exposures. New screen
combinations had been applied to make a computed radiograph of a testing class B quality
possible.
Imaging Capability of Terahertz and Millimeter-Wave Instrumentations for NDT of Polymer Materials
(2006)
In der Filmradiografie kann durch den Einsatz von Metallfolien und Metallfolienkombinationen der Bildkontrast verbessert werden. Die Mechanismen zur Erzeugung der latenten Röntgenbilder und deren Sichtbarmachung für das menschliche Auge sind in Speicherfolien nicht mit denen in einem Röntgenfilm identisch. Demzufolge lassen sich die in den Normen zur Filmradiografie veröffentlichten Empfehlungen zum Einsatz von Metallfolien und zur Auswahl der Röhrenspannung nicht unmittelbar auf die Computer-Radiografie zur Schweißnahtprüfung übertragen. Die Qualität digitaler Röntgenbilder wird von der Bildunschärfe und dem Kontrast-zu-Rausch-Verhältnis (CNR) bestimmt. Während die Norm EN 14784-1 handhabbare Verfahren zur Bestimmung der inneren Unschärfe und des Signal-zu-Rausch-Verhältnisses (SNR) beschreibt, sind die in EN 14784-2 vorgegebenen Vorgehensweisen zur Kontrastverbesserung durch die Vorgaben zur geeigneten Röhrenspannung und Metallfoliendicke für die Schweißnahtprüfung nicht ausreichend dargelegt. Um die Parameter zur Verbesserung der Bildqualität von CR-Systemen für den Fall der radiografischen Durchstrahlungsprüfung von Schweißnähten zu optimieren, wurden systematische Untersuchungen zum Einfluss eines Kupfer-Vorfilters, von Bleifolien-Speicherfolien-Kombinationen und der Röhrenspannung auf den Bildkontrast von Stahlstufenaufnahmen durchgeführt. Auf der Grundlage dieser Ergebnisse wurden Empfehlungen zum Einsatz der Metallfilter und -folienkombinationen sowie zur Auswahl geeigneter Röhrengrenzspannungen für die Speicherfolientechnik zur Optimierung der Durchstrahlungsprüfung von Schweißnähten abgeleitet.
Computed Radiography exposure experiments on welded plate sections
were performed to demonstrate that the requirements for pressure vessels weld
inspection according to EN1435 or EN14784-2 class B can be achieved. The
representative comparative studies of the image qualities were performed with
standardized image quality indicators and image evaluation procedures on both film
and digital radiographs. Recommendations for weld inspections with CR systems
are drawn from the results. It is demonstrated that present CR systems can be used
for weld inspection and produce images with testing class B if the selected X-ray
tube voltage is reduced compared with the max. voltage of EN 14784-2 and set
equivalent to maximum X-ray voltage values for steel as defined in the radioscopic
standard EN 13068-3. The work was part of the European 'Filmfree' Project
promoted during the 6th framework.
In situ crack detection in the mushy zone and the solid weld of a gas tungsten arc (GTA) weld using X-ray imaging during welding is a new research area for NDT inspection. Usually, NDT flaw detection is done after the complete solidification of the weld seam. In this paper, we present the use of real-time radiography with a minifocus X-ray source (YXLON X-ray tube Y.TU 225-D04) and a 75μm pixel size digital detector array (Dexela 1512) for the acquisition of 2D radiographic images by a sequence of exposures with time intervals of 80 ms for hot crack detection during single pass bead-on-plate GTA welding of 3 mm thick plates of aluminium alloy AlMgSi (6060). An analysis of the crack distribution in the weld sample is conducted from the acquired 2D radiographs and its corresponding 3D volumetric reconstruction achieved by linear coplanar digital laminography.
This in situ approach opens new possibilities in the field of hot crack research by having the direct information of both the crack initiation and growth and its correlation to the welding parameters.
Die radiografische Bildqualität in ihrer klassischen Definition hängt von Kontrast, Rauschen und Unschärfe ab. Diese Parameter werden normalerweise mit Bildgüteprüfkörpern (BPK) bestimmt. Die Streustrahlung reduziert im Allgemeinen immer die Bildqualität in der Radiografie. Verschiedene Einflussgrößen werden unter Berücksichtigung von Techniken, wie Film-Radiografie, Computer-Radiografie mit Speicherfolien und digitale Radiographie mit Matrixdetektoren, analysiert. In Lehrbüchern und Standards werden das Streuverhältnis k und verschiedene Kontraste definiert. Für digitale Medien werden zusätzliche Parameter wie das Signal-Rausch-Verhältnis SNR und das Kontrast-Rausch-Verhältnis CNR eingeführt. In diesem Zusammenhang wird der Einfluss der Streustrahlung aus dem Messobjekt und dem Detektor bestehend aus Kassette bzw. Gehäuse und sensitiver Detektorschicht auf die Bildqualität ermittelt. Die numerische Modellierung wird eingesetzt, um die Streustrahlung und die Primärstrahlung aus dem Objekt separat zu bestimmen. Die Streustrahlung aus dem Objekt und Detektor erzeugen eine Abbildung des Objektes, die dem Primärstrahlungsbild überlagert ist, wobei das Streubild eine höhere Unschärfe aufweist. Dieser Effekt hängt von der Fehlergröße, dem Abstand zwischen Detektor und Objekt und der Zwischenfilterung ab.
The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNRmax depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.
Industrial Radiology
(2006)
The digital photography has almost completely substituted the film photography. The film replacement is also fast progressing in medical X-ray radiography. This process is slower in NDT and especially in Europe. Reasons for the hesitating change to digital radiography (RT-D) in NDT are the necessary time for adoption of standards and the conservative request for film RT by auditors and NDT managers for applications in large plants and at construction areas. The fast serial inspection for small castings is already almost completely dominated by RT-D due to the cost effective short exposure and interpretation times. Standards were developed in parallel at CEN, ISO, ASTM and ASME. Unfortunately, the standard practices are different and the requirements on image quality and useable hardware are different too. The first standard series on Computed Radiography were developed and published by CEN and ASTM in 2005. Harmonized classification and qualification standards are available but the published practices are different. ASTM has developed the first standards for application of Digital Detector Arrays (DDA) in 2010. The first digital RT ISO standard practice is ISO 17636-2 (2013), which describes the practice for application of DDAs and Imaging Plates for weld inspection. At the first time this standard provides requirements for the selection of suitable hardware. Minimum image quality requirements are specified in analogy to film radiography and 3 Compensation Principles are defined to enable the application of a wider range of digital detectors. A comparison of the different international digital RT standards is given and first experiences with ISO 17636-2 are discussed. New standards on RT wall thickness and corrosion measurements (EN 16407, film and digital) have been developed recently.
Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei der Prüfpraxis, der Qualitätssicherung in der digitalen Radiographie und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der „Standard Guide for Computed Tomography“, ASTM E 1441, zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wurde revidiert und veröffentlicht. Die Mehrzahl der Hersteller von CT-Anlagen bietet entsprechende Software-Tools an. Weiterhin werden neue Festkörperentwürfe zur Charakterisierung von CT-Anlagen vorgestellt. Die folgenden Revisionen sind bei ASTM derzeit in Bearbeitung: ASTM E 2445, „CR Long Term Stability“ nach einem Round Robin-Test und für DDAs der Standard zur System-Charakterisierung, ASTM E2597/E2597M−14, und zur „DDA Long Term Stability“. Das Spider-Net-Diagramm zur Klassifizierung von DDAs wird um die Position „ISO Material Thickness limit“ erweitert. Der Standard EN 12679 zur Messung der Größe von Gammastrahlern wurde nach Revision unter Berücksichtigung von digitalen Messverfahren veröffentlicht. Die Revision der Standardserie EN 12543 zur Messung der Brennfleckgröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Die Messprozedur für Lochkameras wurde grundlegend revidiert und ist harmonisiert mit ASTM E 1165-12(2017). Die gemessenen Brennflecke unterscheiden sich und passen besser zu den Unschärfe-Messungen
mit Doppeldraht BPKs (ISO 19232-5:2018) bei Vergrößerung. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren und Mikro-Fokusröhren (< 5 µm) wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Es wird über erste Ergebnisse
informiert.
Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised.
Die Voraussetzungen für die Vorhersage der Sichtbarkeit von Bildgüteprüfkörpern (BPK) wurden seit Beginn der kommerziellen Anwendung der technischen Radiographie diskutiert und in diversen nationalen und internationalen Standards festgeschrieben. Diese Fragen werden nach Einführung der digitalen Radiographie und der CT wieder neu diskutiert. Draht BPKs wurden in Deutschland seit 1935 (DIN 1915: 1935) und später in den meisten europäischen Ländern benutzt. In den USA und Frankreich wurden vorzugsweise BPKs mit Löchern verwendet (ASTM E 1025 seit 1984 oder E 1742 seit 1992 bzw. die Vorgängernorm MIL STD-543 seit 1962). Jetzt werden auch die Umrechnungsnormen zur Erkennbarkeit von Draht zu Loch-BPKs in Frage gestellt. ISO 19232-3, der französische RCCM-Kode einerseits und ASTM E 747 und ASME BPVC Section V Tab. T-276 andererseits unterscheiden sich erheblich bei den Anforderungen im Bereich hoher Wandstärken (Hochenergieradiographie). Untersuchungen dazu werden vorgestellt. Mit Einführung der digitalen Detektoren ändern sich auch die Rauschspektren. Durch die Herstellung werden insbesondere bei Speicherfolien "Rauschmuster" eingeprägt, die bei hohen Belichtungsdosen sichtbar werden. Diese veränderten Rauschspektren ergeben auch veränderte Erkennungsparameter für menschliche Bildauswerter. Hierzu wurden an ausgewählten Detektoren MTFs (presampled) und normierte Rauschspektren gemessen. Erweiterte Erkennbarkeits-Formeln zur Vorhersage der Sichtbarkeit von BPKs für Bildauswerter und erste Ergebnisse werden vorgestellt.
Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability assessment of film and digital radiography. NDT of safety relevant components of aerospace industry requires the proof of probability of detection (POD) of the inspection. Modeling tools can reduce the expense of such extended, time consuming NDT trials, if the result of simulation fits to the experiment. Our analytic simulation tool consists of three modules for the description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiography. It features high processing speed with near–interactive frame rates and a high level of realism. A concept has been developed as well as a software extension for reliability investigations, completed by a user interface for planning automatic simulations with varying parameters and defects. Furthermore, an automatic image analysis procedure is included to evaluate the defect visibility. The radiographic modeling from 3D CAD of aero engine components and quality test samples are compared as a precondition for real trials. This enables the evaluation and optimization of film replacement for application of modern digital equipment for economical NDT and defined POD.
This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results.
This work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-tonoise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within the exposure bay, due to a lack of source collimation. These would affect the experimental results but were not included in the simulated setup. This was investigated by including different proportions of peripheral water and other objects in the modelled setup and examining the effect on Image quality parameters. Results show that this additional scatter has a significant impact on the radiograph, particularly on image contrast, and is therefore the likely cause of differences between experimental and simulated images. This implies that it will be very difficult to completely match simulated to experimental results, as including all possible scattering objects in the model would be very complex. An improvement could be made by using real subsea data to estimate this additional scattering, which could then be used to calibrate the model. However there would still be significant uncertainty in the ability of the model to accurately produce realistic intensity and contrast.
Radiological inspections, in general, are the nondestructive testing (NDT) methods to detect the bulk of explosives in large objects. In contrast to personal luggage, cargo or building components constitute a complexity that may significantly hinder the detection of a threat by conventional X-ray transmission radiography. In this article, a novel X-ray backscatter technique is presented for detecting suspicious objects in a densely packed large object with only a single sided access. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattering objects. The new X-ray backscatter camera is not only imaging the objects based on their densities but also by including the influences of surrounding objects. This unique feature of the X-ray backscatter camera provides new insights in identifying the internal features of the inspected object. Experimental mock-ups were designed imitating containers with threats among a complex packing as they may be encountered in reality. We investigated the dependence of the quality of the X-ray backscatter image on (a) the exposure time, (b) multiple exposures, (c) the distance between object and slit camera, and (d) the width of the slit. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security are discussed.
Critical parts in aircraft manufacturing such as stringers are very commonly used in modern aircraft structures to resist the compressive loads caused by the aerodynamic effects. They are generally made-up of thin aluminium (Al) metal sheets and are one of the key components in the aircraft wings. Any defects in the stringer leads to weakening of the stiffness of the whole wing structure and consequently, failures may occur. Hence, the structural integrity of the stringers should be evaluated using reliable non-destructive testing (NDT) methods. Due to the complex shaped structure of the stringer, the one-sided access NDT method such as X-ray backscatter technique is more preferable for the non-destructive imaging. In this paper, we present a new X-ray backscatter technique to image the internal sections of the stringer with only a single-sided access. The whole object was inspected by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (> 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed.
This paper presents a new X-ray backscatter technique (XBT) for non-destructive imaging of aerospace materials with only a single-sided access. It uses a special twisted slit collimator to inspect the whole object by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (>500 keV) X-ray sources. Experiments were performed on thick complex structured aluminium components, stringers and honeycomb structures to validate the applicability of the present technique to image small changes in the material properties and also to detect low-density material inclusions. In order to reduce the inspection time from hours to several seconds and to improve the image quality of the X-ray backscatter image, the backscattered signals were measured using a digital detector array with high spatial resolution (200 µm). The influence of the energy of the X-ray source and the slit width of the camera on the X-ray backscatter image were also investigated. In the proposed technique, the whole object is irradiated by an un-collimated X-ray beam resulting in a low image acquisition time of 3 min that facilitates the use of XBT for the real time NDT&E of aerospace materials.
The reliability investigations are dedicated to throw light on the performance of the NDE system with
respect to the required aim. This is especially of interest when digitized and processed signals are
involved where it becomes hard to assess whether the quality of the system has raised or not. Three
different ways to investigate reliability of NDE signals will be described. The first way of investigation,
the performance demonstration, is preferred e.g. in the US American nuclear power industry. This is an
integral consideration of the non destructive test as a system where the whole NDE system is packed in a
black box and only the input in terms of the real existing flaws in the component is considered and
compared to the output in terms of the indications of the human inspector or of the automated system.
The second the European tradition relies on a standardized description of physical/technical
parameters of the NDE system which are preconditions for successful system performance. An example
for such a standardized set of performance parameters is given in the recently released standard about Xray
film digitization CEN EN 14096. The third approach the modular conception is a marriage of
both: The signal chain is cut into main modules. Each module is assessed in a most appropriate
individual way e.g. via modeling calculations. The single results are joint together according to the
reliability of the subsystems. Separating criteria for the system were proposed through a reliability
formula developed during a series of European-American workshops on NDE reliability. Examples of
all three approaches will be given.
An algorithm has been developed to remove reliably dotted interferences impairing the perceptibility of objects within a radiographic image. This particularly is a major challenge encountered with neutron radiographs collected at the NECTAR facility, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II): the resulting images are dominated by features resembling a snow flurry. These artefacts are caused by scattered neutrons, gamma radiation, cosmic radiation, etc. all hitting the detector CCD directly in spite of a sophisticated shielding. This makes such images rather useless for further direct evaluations.
One approach to resolve this problem of these random effects would be to collect a vast number of single images, to combine them appropriately and to process them with common image filtering procedures. However, it has been shown that, e.g. median filtering, depending on the kernel size in the plane and/or the number of single shots to be combined, is either insufficient or tends to blur sharp lined structures. This inevitably makes a visually controlled processing image by image unavoidable. Particularly in tomographic studies, it would be by far too tedious to treat each single projection by this way. Alternatively, it would be not only more comfortable but also in many cases the only reasonable approach to filter a stack of images in a batch procedure to get rid of the disturbing interferences.
The algorithm presented here meets all these requirements. It reliably frees the images from the snowy pattern described above without the loss of fine structures and without a general blurring of the image. It consists of an iterative, within a batch procedure parameter free filtering algorithm aiming to eliminate the often complex interfering artefacts while leaving the original information untouched as far as possible.
Stochastic artefacts are frequently encountered in digital radiography and tomography with neutrons. Most obviously, they are caused by ubiquitous scattered radiation hitting the CCD-sensor. They appear as scattered dots and, at higher frequency of occurrence, they may obscure the image. Some of these dotted interferences vary with time, however, a large portion of them remains persistent so the problem cannot be resolved by collecting stacks of images and to merge them to a median image. The situation becomes even worse in computed tomography (CT) where each artefact causes a circular pattern in the reconstructed plane. Therefore, these stochastic artefacts have to be removed completely and automatically while leaving the original image content untouched. A simplified image acquisition and artefact removal tool was developed at BAM and is available to interested users. Furthermore, an algorithm complying with all the requirements mentioned above was developed that reliably removes artefacts that could even exceed the size of a single pixel without affecting other parts of the image. It consists of an iterative two-step algorithm adjusting pixel values within a 3 × 3 matrix inside of a 5 × 5 kernel and the centre pixel only within a 3 × 3 kernel, resp. It has been applied to thousands of images obtained from the NECTAR facility at the FRM II in Garching, Germany, without any need of a visual control. In essence, the procedure consists of identifying and tackling asymmetric intensity distributions locally with recording each treatment of a pixel. Searching for the local asymmetry with subsequent correction rather than replacing individually identified pixels constitutes the basic idea of the algorithm. The efficiency of the proposed algorithm is demonstrated with a severely spoiled example of neutron radiography and tomography as compared with median filtering, the most convenient alternative approach by visual check, histogram and power spectra analysis.
Neutrons are absorbed particularly by hydrogen containing materials so
they can be used as a tool for visualising heterogeneous density distributions of organic materials. Penetration limits are set by the layer thicknesses and the neutron energies applied. In case of specimens with a flat shape the situation may be encountered that the object only could be penetrated in selected directions. In addition, the overall size may exceed the beam diameter and thus the viewing window if a certain region of interest should be studied by tomography without destroying the integrity of the specimen.
This study shows the capabilities and limits of thermal and fast neutrons to investigate flat wooden specimens such as boards and girders by neutron tomography under such circumstances. Taking projections was impaired either by the limits of penetrability or by the total size of the object. As a consequence, projections were included for reconstruction only from a limited angular range of 90°. It could be shown that an approach based on the slice theorem was capable to visualise structural features along the beam directions while simply omitting the perpendicular ones without causing additional artefacts.
Small samples with a thickness of up to 2 cm but several times broader could be studied with the ANTARES facility of the FRM II neutron source in Garching providing thermal neutrons while larger objects required a beam of higher energy as available in the NECTAR facility of the same institution. The fast (fission) neutrons (1.5 – 2 MeV) of this site allowed investigating an area of interest inside a girder with a cross section of 23.5 x 49 cm². Internal features such as inclusions could be detected as well as a heterogeneous density distribution in glue layers.
The effective high neutron scattering absorption coefficient of hydrogen (48.5 cm²/g) due to the scattering allows neutrons to reveal hydrocarbon structures with more contrast than X-rays, but at the same time limits the sample size and thickness that can be investigated. Many planar shaped objects, particularly wood samples, are sufficiently thin to allow thermal neutrons to transmit through the sample in a direction perpendicular to the planar face but not in a parallel direction, due to increased thickness. Often, this is an obstacle that prevents some tomographic reconstruction algorithms from obtaining desired results because of inadequate information or presence of distracting artifacts due to missing projections. This can be true for samples such as the distribution of glue in glulam (boards of wooden layers glued together), or the course of partially visible annual rings in trees where the features of interest are parallel to the planar surface of the sample. However, it should be possible to study these features by rotating the specimen within a limited angular range. In principle, this approach has been shown previously in a study with fast neutrons [2]. A study of this kind was performed at the Antares facility of FRM II in Garching with a 2.6×107/cm² s thermal neutron beam. The limit of penetration was determined for a wooden step wedge carved from a 2 cm×4 cm block of wood in comparison to other materials such as heavy metals and Lucite as specimens rich in hydrogen. The depth of the steps was 1 cm, the height 0.5 cm. The annual ring structures were clearly detectable up to 2 cm thickness. Wooden specimens, i.e. shivers, from a sunken old ship have been subjected to tomography. Not visible from the outside, clear radial structures have been found that are typical for certain kinds of wood. This insight was impaired in a case where the specimen had been soaked with ethylene glycol. In another large sample study, a planar board made of glulam has been studied to show the glued layers. This study shows not only the limits of penetration in wood but also demonstrates access to structures perpendicular to the surface in larger planar objects by tomography with fast neutrons, even with incomplete sets of projection data that covers an angular range of only 90° or even 60°.
Verleimte Holzproben wurden je nach Größe mit thermischen (ANTARES) bzw. schnellen Neutronen (NECTAR) an der Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) der Technischen Universität München in Garching untersucht. Entweder ließen die durchstrahlbare Schichtdicke oder die eingeschränkte Strahlgeometrie es nicht zu, das Probenteil allseitig zu durchstrahlen.
Um dennoch innere Strukturen wie Leimschichten zumindest mit einem eingeschränkten Winkelbereich tomographisch darzustellen, wurde mit Hilfe des Slice-Theorems erfolgreich rekonstruiert. Ein Brett von 2 cm Dicke wurde mit thermischen Neutronen erfolgreich untersucht, ein größeres mit schnellen.
Throughout human history, wood has been used for various purposes: for
building shelters, houses and bridges, for manufacturing furniture and
household or agricultural appliances (from ploughs to spoons), as burning
material or simply as walking sticks. Contemporarily, vast amounts of wood
are going into paper production. As a consequence, different qualities of
wood are selected appropriately for the various applications. Beams incorporated
into buildings and constructions have to be sturdy and durable;
boards for furniture are supposed to be free of knots or are expected to have
certain ornamental structures. As long as wood is not simply destined for
burning it should be free of undesired knots or internal damages such as rot
or worm holes. Particularly in cases of infestation with wood destroying
fungi that definitely impairs mechanical strength and even may generate
hollows such damages are frequently invisible from the outside. Radiographic
methods are capable to detect internal damages as well as hidden
knots without the need of drilling holes or cutting a specimen to pieces.
The most thoroughly method to visualise the interior of a wooden specimen
is tomography which shows annual growth rings in their complete circumference
and all the knots or damages that might be included. However, some
of them as well as patterns of annual rings suitable for dendrological investigations
are recognisable with a less laborious method that might be applicable
even in the field, i.e. contemporary digital radiography combined with
image processing. Samples of lumber shall be presented showing the typical
annual ring structures and some infested areas.
Die radiologische Untersuchung von Holz ist hinsichtlich der Durchführung
und Auswertung komplex. Im Gegensatz zu künstlich hergestellten Materialien zeichnet
sich Holz besonders durch seine Heterogenität und Individualität aus, kein Stück ist wie das
andere. Dies erschwert bei der radiologischen Inspektion die Fehlerdetektion, da diese teilweise
schwer von natürlichen Wachstumsmerkmalen zu unterscheiden sind. Insektenfraßgänge
und Hohlräume durch biologischen Abbau sind deutlich erkennbar, schwieriger
wird es bei feinen Rissen und Anzeichen für Fäulnis. Metallische Einbauten wie Nägel und
Bolzen sind natürlich gut zu erkennen, großflächigere Platten können jedoch den Einblick
in die benachbarten Gebiete versperren. Klebstoffschichten sind im Röntgenbild nur dann
sichtbar, wenn sie exakt parallel zum Strahlengang getroffen werden. Verschiedene
Strukturmerkmale treten also radiologisch recht unterschiedlich in Erscheinung, deshalb
liegt es nahe, zu deren Erkennung mehr als nur eine Durchstrahlungstechnologie
anzuwenden. Während bei immobilen Objekten, d.h. Bauwerken und Bäumen, mobile
Durchstrahlungstechniken mit Röntgen- oder Gammastrahlen (Se-75) in Frage kommen,
stehen im Labor auch (schnelle) Neutronen alternativ zur Verfügung. Die verschiedenen
Techniken, einschließlich der Tomographie mit Neutronen, werden an zwei größeren Prüfteilen
demonstriert, einer Brettschichtholzprobe und einem Knotenpunkt aus einer Holzbrücke
mit eingebauter Stahlplatte. Neutronen lassen Materialunterschiede differenzierter hervortreten
und durchdringen sperrige Metallteile besser, trotz verringerter Bildqualität. An
Verbesserungen wird derzeit gearbeitet.
Wood is the material that has accompanied the whole development of mankind in various applications, for manufacturing tools and weapons, for buildings and constructions and also as fuel. It has various appearances and is subjected to decomposing changes, so there are sufficient arguments for non-destructive testing of wooden objects in the same way as is common practice with other technologically used materials. However, even today wood is rarely tested. Moreover, artefacts of cultural heritage containing wood are rare and delicate, so dismantling these for studying purposes is undesirable. Radiological inspection technologies are the methods of choice to provide a non-destructive insight. Interrogations of a specimen with various kinds of radiation provide different answers about their internal structures. High-quality detailed images are achievable with X-rays or gamma radiation in cases where heavy metals or other dense materials are not involved. Neutrons behave complementarily; they are avidly absorbed by light elements such as hydrogen on the one hand and yet are capable of easily penetrating heavy metals on the other. This provides an alternative for X-ray radiography and tomography when material characteristics are of primary interest rather than structural details, or when shielding with plates or sleeves of heavy metal severely impedes inspections with X-ray or gamma radiation technologies. However, due to the moderating effect of wooden samples it is essential to use fast neutrons for radiography and tomography of voluminous objects. Some typical examples described here will show the difference between neutron and X-ray photon-based radiographic technologies.
Abweichend von der gängigen Vorgehensweise, mit einem Bleistiftstrahl
die Lage eines Bildpunktes festzulegen und die rückgestreute Strahlung großflächig aufzunehmen, bietet die neu entwickelte Kamera Unabhängigkeit von Einstrahl- und Blickrichtung. Ausgestattet mit einer 'Optik' für hochenergetische Strahlung, wie die bereits beschriebene Schlitzblendenkamera, ist die variable Gestaltung von Einstrahl- und Blickrichtung möglich. Damit eröffnet sich die
Chance, Strahlung absorbierende Details in einem Objekt sichtbar werden zu lassen, die sonst von einer streuenden Umgebung überstrahlt würden. Zudem wird gezeigt, wie sich das Erscheinungsbild von Objekten umgebungsbedingt im Rückstreubild ändern kann.
Threat detection and imaging
(2007)
Tomographical Computer Aided Radiology (TomoCAR) is based on the mechanical position control of
an X-ray tube in front of a welding seam and the application of a planar array detector behind it. Several hundred
radiometric projections in small angle steps are acquired. The tomographical reconstruction allows the three-dimensional
(3D) representation of the defects. A new radiometric array detector system with a small internal
unsharpness and high image contrast is used for the 2- and 3-dimensional visualization and sizing of planar defects
with a defect opening of less than 100 µm. This detector is based on a CMOS-flat panel with a direct converting
CdTe-single crystal layer. The small design allows the application of the mobile testing equipment for mechanized
X-ray inspection in industrial plants. The physical pixel size of the detector amounts to 0,1x0,1 mm². Nevertheless,
this system yields a better spatial resolution than indirect converting detectors (e.g. cameras with fluorescence
layers of Gd2O2S). It allows the reliable detection of planar defects with openings far below the detector pixel size
by subpixel resolution.
'TomoCAR' is qualified at present in the context with a German pilot study following to the ENIQ guidelines for
the employment within the nuclear power industry.
Classical film radiography is a well-established NDT technique and it is most commonly used for testing weld seams and corroded pipes e.g. in oil and gas industry or in nuclear power plants. In the course of digitization, digital detector arrays (DDA) are finding their way into industrial applications and are replacing film radiography step by step. This study deals with the latest generation of DDAs, the photon counting and energy resolving detectors (PCD), and their characteristics compared to charge integrating detectors (CID). No matter which technology to use, radiography still lacks a general issue: A three-dimensional object is projected onto a two dimensional image. Of course, advanced computed tomography (CT) algorithms exist since many years, but if the object to investigate is too large to fit into the manipulation system or its shape is not appropriate, CT is not feasible or sensible to be applied. To overcome this limitation, numerous laminographic algorithms have been developed in the past. In this study, photon counting detectors are used in combination with co-planar translational laminography to gain reconstructed three-dimensional volumes. Both laminographic testing and PCDs require a serious knowledge of many parameters that can influence the image quality in the resulting datasets. These are e.g. the detector efficiency and calibration procedure, setting of energy thresholds, exposure data, number of projections, beam length correction and spatial resolution. The use of PCDs yields more variables to be considered compared to CIDs. The most important parameters in laminographic testing and in the use of PCDs are described in this study and limits are discussed.
Since a few years the direct detection of X-ray photons into electrical signals is possible by usage of highly absorbing photo conducting materials (e.g. CdTe) as detection layer of an underlying CMOS semiconductor X-ray detector. Even NDT energies up to 400 keV are possible today, as well. The image sharpness and absorption efficiency is improved by the replacement of the unsharp scintillation layer (as used at indirect detecting detectors) by a photo conducting layer of much higher thickness. If the read-out speed is high enough (ca. 50 – 100 ns dead time) single X-ray photons can be counted and their energy measured. Read-out noise and dark image correction can be avoided. By setting energy thresholds selected energy ranges of the X-ray spectrum can be detected or suppressed. This allows material discrimination by dual-energy techniques or the reduction of image contributions of scattered radiation, which results in an enhanced contrast sensitivity. To use these advantages in an effective way, a special calibration procedure has to be developed, which considers also time dependent processes in the detection layer. This contribution presents some of these new properties of direct detecting digital detector arrays (DDAs) and shows first results on testing fiber reinforced composites as well as first approaches to dual energy imaging.
Recent developments of photon counting and energy discriminating detectors for radiographic imaging
(2018)
The direct detection of X-ray photons into electrical signals is enabled by usage of highly absorbing photo conducting materials (e.g. CdTe) as detection layer of an underlying CMOS semiconductor X-ray image detector. If the read-out speed is high enough (ca. 50 - 100 ns dead time) single X-ray photons can be counted and their energy measured. Read-out noise and dark image correction can be diminished. By setting energy thresholds, selected energy ranges of the X-ray spectrum can be detected or suppressed. This allows material discrimination or reduction of scattered radiation, which results in an enhanced contrast sensitivity.
A comparative study on the performance of digital detector systems for high energy applications
(2014)
For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements.
The literature has shown that the application of laminography provides advantages as 3D radiographic imaging with depth information for in house and mobile testing. This permits to distinguish between overlapping indications, measure the extension along radiation direction and classify indications as surface open or subsurface
ones as required in critical engineering assessment. This work provides a comparative study and measurements of the three techniques Digital Radiography (DR) with Digital Detector Arrays (DDA), Coplanar Translational Laminography (CTL) and Computed Tomography (CT), applied for composite pipeline inspection. It is demonstrated that CTL and CT provide advantages for the evaluation of pipe-to-pipe connections and the evaluation of adhesive applications. They show indications of discontinuities with higher contrast sensitivity than radiography.
Beyond it, two specimen, namely Phantom 1 and Phantom 2, were developed and manufactured by additive manufacturing to analyze the preferential detection sensitivity and the direction of features and depth information for laminographic measurements. Another goal was to show the laminographic capabilities to distinguish between overlapping discontinuities. CTL is especially suitable for mobile inspection. Special glass fiber reinforced polymer samples (GRP) were manufactured for further analysis and comparisons between the abovementioned techniques. Finally, Phantoms 1 and 2 show the capability of laminography to detect overlapping indications and also show that discontinuities oriented perpendicular to the scan direction have the highest contrast sensitivity for laminographic measurements.
Innovative X-ray backscatter technique for security applications: Detection of dangerous materials
(2014)
Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed.
Since decades the evaluation of flaw indications on radiographs from welds or castings are based on well accepted reference film catalogues from organizations like IIW (weldments), ASTM (castings) or DGZfP (D5 recommendation on heavy steel castings). Today, the transformation of classical film radiography to the digital world is in full progress. Some ASTM standards do not permit the evaluation of digital radiographs in reference to film catalogues. Therefore, these reference film catalogues have to be converted into the digital age too. BAM is supporting this transition by high definition film scanning. The result is a corresponding reference image catalogue. The different standard organizations selected different ways to distribute the digital data. ASTM used high definition film scanning at 10 μm pixel size and distribution of a huge amount of high-res data via DVD. The user sub-samples these high-res data during catalogue import to the resolution of his system. The comparison is done by synchronized image viewing on the computer work station. IIW recently decided to distribute their ISO 5817 reference images installed on tablets, which are used for image viewing too. The tablet image has to be compared with the digital image on the system monitor. DGZfP transformed their D5 reference radiographs into a PDF for monitor viewing. This is the simplest and cheapest solution, but still allows the full usage of the catalogue in the digital era. The status of ongoing work in progress will be discussed.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der zerstörungsfreien Prüfung wurde in den letzten 10 Jahren kontrovers diskutiert. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wurde erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollziehen sollte. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Speicherfolientechnik eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte erreicht werden kann. Es wird ein Überblick gegeben, welche Parameter zum praktischen Einsatz wichtig sind und wie sie ermittelt werden. Erste Erfahrungen im praktischen Einsatz werden diskutiert.
Industrial Radiology is used for volumetric inspection of industrial objects. By penetration of these objects (typically weldments, pipes or castings) with X-ray or Gamma radiation the 3D-volume is projected onto a 2D image detector. The X-ray film is the oldest radiographic image detector and still in wide use in industry. The industrial X-ray film systems used today differ from these used in medicine. Medical film systems are described well in the literature, but industrial film systems not. So we start with a description of the properties and standards for industrial film systems. The requirements on image quality are defined by several standards and can be verified with different image quality indicators (IQIs). They describe the ability of the human being to detect small and low contrast indications in a noisy image background. The essential parameters for digital industrial radiology are described.
Since about 30 years electronic image detectors are gradually replacing the industrial film. These detectors are based on storage phosphor imaging plates in combination with Laser scanners (“Computed Radiography”, CR) or a variety of different digital detector arrays (DDA). Typical applications of CR and DDAs are discussed as well as new possibilities by digital image processing, which is enabled by the computer based image handling, processing and analysis.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der Zerstörungsfreien Prüfung im Anlagenbau wird seit 2013 durch neue ISO-Normen unterstützt. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wird erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollzieht. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Computerradiographie mit Speicherfolien eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 zur Schweißnahtprüfung wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte (Fehlernachweißempfindlichkeit) erreicht wird. Ein Überblick zeigt, welche Parameter für den praktischen Einsatz wichtig sind und wie sie ermittelt werden. Praktische Einsatzbeispiele im Anlagenbau werden diskutiert.
In den letzten zwei Jahren wurden 11 neue Standards/Standardrevisionen zur RT veröffentlicht (ohne Strahlenschutz) und 5 werden dafür gestrichen. Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei Prüfpraxis und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Die Standards zur Schweißnahtprüfung in der Kerntechnik, DIN 25435, wurden ins Englische übertragen und bei ISO TC 85 SC 6 bearbeitet. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der Guide ASTM E 1441 zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wird revidiert. E 2445 zur CR Long Term Stability wird ebenfalls revidiert. Die Revision soll auch in die ISO 16371-1 eingehen. Dazu ist ein Round Robin-Test geplant. Auch die Standards zur Durchstrahlungsprüfung auf Korrosion und Ablagerungen in Rohren mit Röntgen- und Gammastrahlen (EN 16407-1, -2, 2014) wurden revidiert. Diese Revision wurde als DIN EN ISO 20769-1, -2 2018 veröffentlicht und EN 16407 wird zurückgezogen. Die Revision der Standards EN 12543 und EN 12679 zur Messung der Brennfleckgröße und der Strahlergröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Zur radiographischen Gussteilprüfung wurde der Standard EN 12681 revidiert und 2018 veröffentlicht. Er wurde um Zulässigkeitsgrenzen erweitert und die digitale Radiographie wurde in Teil 2 berücksichtigt.
Concepts for digital image evaluation are presented for Computed Radiography (CR) and Digital Detector Arrays (DDAs) used for weld inspection. The precise DDA calibration yields an extra ordinary increase of contrast sensitivity up to 10 times in relation to film radiography. Restrictions in spatial resolution caused by pixel size of the DDA are compensated by increased contrast sensitivity. First CR standards were published in 2005 to support the application of phosphor imaging plates in lieu of X-ray film, but they need already a revision based on experiences reported by many users. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film and film system class. The contrast sensitivity, measured by IQI visibility, depends on three essential parameters: The basic spatial resolution (SRb) of the radiographic image, the achieved signal-to-noise ratio (SNR) and the specific contrast (µeff - effective attenuation coefficient). Knowing these 3 parameters for the given exposure condition, inspected material and monitor viewing condition permits the calculation of the just visible IQI element. Furthermore, this enables the optimization of exposure conditions. The new ISO/FDIS 17636-2 describes the practice for digital radiography with CR and DDAs. It considers the first time compensation principles, derived from the three essential parameters. The consequences are described.
The progress in X-ray detector electronics (sensitivity and speed) allows meanwhile fast single photon detection by a matrix detector. Combined photon counting and energy discrimination is implemented in the electronic circuit of each detector pixel. The company XCounter developed detectors based on CdTe single crystals, which can be tiled to larger areas and have a pixel size of 100ìm. The largest area available in beginning of 2014 is 50x75 mm². These detectors have very promising properties, which make them very suitable for NDT applications:
1. A CdTe attenuation layer of 750 µm thickness allows efficient X-ray detection up to ca. 300 keV. In counting mode only photon noise is important; no other detector noise sources need to be considered. There is no Offset signal without radiation.
2. Each of the detector pixels has two energy thresholds. These can be used for dual energy imaging for materials separation. Also the suppression of scattered radiation by energy thresholding will improve the image contrast sensitivity. First experiments will be presented which demonstrate the advantages of this new detector technology over the conventional charge integrating detectors.
A challenge is the development of a modified detector calibration procedure, which becomes critical at longer exposure times.