Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (79)
- Sonstiges (15)
- Vortrag (4)
- Beitrag zu einem Tagungsband (3)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (93)
- Deutsch (11)
- Mehrsprachig (1)
Schlagworte
- ELISA (13)
- Affinity chromatography (8)
- Antibodies (8)
- Immunoassay (8)
- Antibody (7)
- IgG (7)
- Lab-on-a-chip (7)
- Reproducibility (7)
- Biosensor (6)
- HPLC (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (60)
- 1.5 Proteinanalytik (60)
- 1.9 Chemische und optische Sensorik (9)
- 6 Materialchemie (8)
- 1.8 Umweltanalytik (7)
- 6.3 Strukturanalytik (7)
- 1.1 Anorganische Spurenanalytik (6)
- 1.4 Prozessanalytik (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- VP Vizepräsident (3)
- VP.1 eScience (3)
- 4 Material und Umwelt (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.2 Biophotonik (1)
- 1.3 Instrumentelle Analytik (1)
- 6.7 Materialsynthese und Design (1)
- P Präsident (1)
- PST Präsidiale Stabsstelle (1)
Eingeladener Vortrag
- nein (4)
A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques
(2012)
The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions.
A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications.
Aflatoxins, a group of structurally related mycotoxins, are well known for their
toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein
conjugates are needed for diverse analytical applications. This work describes a reliable
and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and
characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine
serum albumin conjugates were prepared and characterised by UV absorption and
MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens
for the generation of aflatoxin selective antibodies with novel specificities.
A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including top cover to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 µL of sample and flow-rates of 110150 µL min-1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L-1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible.
Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure).
Antibodies are a promising tool for the fast and selective trace detection of explosives. Unfortunately, the production of high-quality antibodies is not trivial and often expensive. Therefore, excellent antibodies are a rare and limiting resource in fields such as biosensing, environmental analysis, diagnostics, cancer therapy, and proteomics. Here, we report the synthesis, bioconjugation, and application of the structurally optimized hapten 6-(2,4,6-trinitro)-phenylhexanoic acid to improve the selectivity and sensitivity of antibodies for the detection of one of the most important explosives, trinitrotoluene. With a conjugate of bovine serum albumin and a highly purified N-hydroxy-succinimide (NHS)activated hapten, two rabbits were immunized to obtain polyclonal antibodies. The immunization process was monitored by enzyme-linked immunosorbent assay to gain information about the progress of antibody titer and affinity. Finally, the polyclonal antibodies reached an affinity constant of (5.1 ± 0.6) × 109l/mol (rabbit R1) and (2.3 ± 0.2) × 109l/mol (rabbit R2). The respective assays show a minimum test midpoint (IC50 value) of 0.1 ± 0.01 µg/l (R1) and 0.2 ± 0.02 µg/l (R2) and a working range of 0.005 to 150 µg/l (R1) and 0.007 to 200 µg/l (R2), which corresponds to more than four orders of magnitude for both. This is quite remarkable for a competitive immunoassay, which is often believed to have a narrow dynamic range. The limit of detection was calculated to 0.6 ng/l (R1) and 1.5 ng/l (R2), which is up to 100 times improvement in relation to the assay of Zeck et al. (1999) on the basis of a monoclonal antibody. The excellent selectivity of the polyclonal antibodies was comprehensively examined by determining the cross-reactivity to common explosives and other nitroaromatics including nitro musk components. The widely held belief that polyclonal antibodies generally display higher cross-reactivities than monoclonals could be disproved.
A series of new epoxide-based monoliths is synthesized by self-polymerization of polyglycerol polyglycidyl ether as porous support for affinity chromatography. Porosity and mean pore sizes are investigated as a function of the porogen ratio and analyzed by mercury porosimetry. The morphologies are visualized by environmental scanning electron microscope. With a particularly rigid monolith prepared with 75 vol% porogen (66% porosity and 12 µm mean pore size), a capillary column (0.5 mm ID) is prepared and directly functionalized with recombinant protein A to extract immunoglobulin G from rabbit serum.
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial,we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules. After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
Current trends in materials and life sciences are flanked by the need to push detection limits to single molecules or single cells, enable the characterization of increasingly complex matrices or sophisticated nanostructures, speed up the time of analysis, reduce instrument complexity and costs, and improve the reliability of data. This requires suitable analytical tools such as spectroscopic, separation and imaging techniques, mass spectrometry, and hyphenated techniques as well as sensors and their adaptation to application-specific challenges in the environmental, food, consumer product, health sector, nanotechnology, and bioanalysis. Increasing concerns about health threatening known or emerging pollutants in drinking water, consumer products, and food and about the safety of nanomaterials led to a new awareness of the importance of analytical sciences. Another important driver in this direction is the increasing demand by legislation, particularly in view of the 17 sustainable development goals by the United Nations addressing clean energy, industry, and innovation, sustainable cities, clean water, and responsible consumption and production. In this respect, also the development of analytical methods that enable the characterization of material flows in production processes and support recycling concepts of precious raw materials becomes more and more relevant. In the future, this will provide the basis for greener production in the chemical industry utilizing recycled or sustainable starting materials.
This makes analytical chemistry an essential player in terms of the circular economy helping to increase the sustainability of production processes. In the life sciences sector, products based on proteins, such as therapeutic and diagnostic antibodies, increase in importance. These increasingly biotechnologically produced functional biomolecules pose a high level of complexity of matrix and structural features that can be met only by highly advanced methods for separation, characterization, and detection. In addition, metrological traceability and target definition are still significant challenges for the future, particularly in the life sciences.
However, innovative reference materials as required for the health and food sector and the characterization of advanced materials can only be developed when suitable analytical protocols are available. The so-called reproducibility crisis in sciences underlines the importance of improved measures of quality control for all kinds of measurements and material characterization. This calls for thorough method validation concepts, suitable reference materials, and regular interlaboratory comparisons of measurements as well as better training of scientists in analytical sciences.
The important contribution of analytical sciences to these developments is highlighted by a broad collection of research papers, trend articles, and critical reviews from these different application fields. Special emphasis is dedicated to often-overlooked quality assurance and reference materials.
ADAMTS4-specific MR-probe to assess aortic aneurysms in vivo using synthetic peptide libraries
(2022)
The incidence of abdominal aortic aneurysms (AAAs) has substantially increased during the last 20 years and their rupture remains the third most common cause of sudden death in the cardiovascular field after myocardial infarction and stroke. The only established clinical parameter to assess AAAs is based on the aneurysm size. Novel biomarkers are needed to improve the assessment of the risk of rupture. ADAMTS4 (A Disintegrin And Metalloproteinase with ThromboSpondin motifs 4) is a strongly upregulated proteoglycan cleaving enzyme in the unstable course of AAAs. In the screening of a one-bead-one-compound library against ADAMTS4, a low-molecular-weight cyclic peptide is discovered with favorable properties for in vivo molecular magnetic resonance imaging applications. After identification and characterization, it’s potential is evaluated in an AAA mouse model. The ADAMTS4-specific probe enables the in vivo imaging-based prediction of aneurysm expansion and rupture.
MALDI-TOF-MS-Based Identification of Monoclonal Murine Anti-SARS-CoV-2 Antibodies within One Hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used 35 monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied to the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 60 min and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 degrees C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
Protein immobilization for the functionalization of particles is used in various applications, including biosensors, lateral-flow immunoassays (LFIA), bead-based assays, and others. Common methods for the quantification of bound protein are measuring protein in the supernatant before and after coating and calculating the difference. This popular approach has the potential for a significant overestimation of the amount of immobilized protein since layers not directly bound to the surface (soft protein corona) are usually lost during washing and handling. Only the layer directly bound to the surface (hard corona) can be used in subsequent assays. A simplified amino acid analysis method based on acidic hydrolysis and RP-HPLC-FLD of tyrosine and phenylalanine (aromatic amino acid analysis, AAAA) is proposed to directly quantify protein bound to the surface of gold nano- and latex microparticles. The results are compared with indirect methods such as colorimetric protein assays, such as Bradford, bicinchoninic acid (BCA), as well as AAAA of the supernatant. For both particle types, these indirect quantification techniques show a protein overestimation of up to 1700% compared to the direct AAAA measurements. In addition, protein coating on latex particles was performed both passively through adsorption and covalently through EDC/sulfo-NHS chemistry. Our results showed no difference between the immobilization methodologies. This finding suggests that usual protein determination methods are no unambiguous proof of a covalent conjugation on particles or beads.
MALDI-TOF-MS-based identification of monoclonal murine anti-SARS-CoV-2 antibodies within one hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used thirty-five monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied onto the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 45 minutes and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 °C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0 (https://gets.shinyapps.io/ABID/). This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
Fast and accurate determination of the protein content of a sample is an important and non-trivial task of many biochemical, biomedical, food chemical, pharmaceutical, and environmental research activities. Different methods of total protein determination are used for a wide range of proteins with highly variable properties in complex matrices. These methods usually work reasonably well for proteins under controlled conditions, but the results for non-standard and complex samples are often questionable. Here, we compare new and well-established methods, including traditional amino acid analysis (AAA), aromatic amino acid analysis (AAAA) based on the amino acids phenylalanine and tyrosine, reversed-phase liquid chromatography of intact proteins with UV absorbance measurements at 220 and 280 nm (LC-220, LC-280), and colorimetric assays like Coomassie Blue G-250 dye-binding assay (Bradford) and bicinchoninic acid (BCA) assay. We investigated different samples, including proteins with challenging properties, chemical modifications, mixtures, and complex matrices like air particulate matter and pollen extracts. All methods yielded accurate and precise results for the protein and matrix used for calibration. AAA, AAAA with fluorescence detection, and the LC-220 method yielded robust results even under more challenging conditions (variable analytes and matrices). These methods turned out to be well-suited for reliable determination of the protein content in a wide range of samples, such as air particulate matter and pollen.