Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (79)
- Sonstiges (15)
- Vortrag (4)
- Beitrag zu einem Tagungsband (3)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (93)
- Deutsch (11)
- Mehrsprachig (1)
Schlagworte
- ELISA (13)
- Affinity chromatography (8)
- Antibodies (8)
- Immunoassay (8)
- Antibody (7)
- IgG (7)
- Lab-on-a-chip (7)
- Reproducibility (7)
- Biosensor (6)
- HPLC (6)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (60)
- 1.5 Proteinanalytik (60)
- 1.9 Chemische und optische Sensorik (9)
- 6 Materialchemie (8)
- 1.8 Umweltanalytik (7)
- 6.3 Strukturanalytik (7)
- 1.1 Anorganische Spurenanalytik (6)
- 1.4 Prozessanalytik (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 8 Zerstörungsfreie Prüfung (3)
Eingeladener Vortrag
- nein (4)
Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody.
The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters.
Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LCMS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques
(2012)
The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions.
A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications.
Aflatoxins, a group of structurally related mycotoxins, are well known for their
toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein
conjugates are needed for diverse analytical applications. This work describes a reliable
and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and
characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine
serum albumin conjugates were prepared and characterised by UV absorption and
MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens
for the generation of aflatoxin selective antibodies with novel specificities.
A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including top cover to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 µL of sample and flow-rates of 110150 µL min-1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L-1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible.
Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure).
An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable.
High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples.
Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody
(2009)
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.
Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples.
Antibodies are a promising tool for the fast and selective trace detection of explosives. Unfortunately, the production of high-quality antibodies is not trivial and often expensive. Therefore, excellent antibodies are a rare and limiting resource in fields such as biosensing, environmental analysis, diagnostics, cancer therapy, and proteomics. Here, we report the synthesis, bioconjugation, and application of the structurally optimized hapten 6-(2,4,6-trinitro)-phenylhexanoic acid to improve the selectivity and sensitivity of antibodies for the detection of one of the most important explosives, trinitrotoluene. With a conjugate of bovine serum albumin and a highly purified N-hydroxy-succinimide (NHS)activated hapten, two rabbits were immunized to obtain polyclonal antibodies. The immunization process was monitored by enzyme-linked immunosorbent assay to gain information about the progress of antibody titer and affinity. Finally, the polyclonal antibodies reached an affinity constant of (5.1 ± 0.6) × 109l/mol (rabbit R1) and (2.3 ± 0.2) × 109l/mol (rabbit R2). The respective assays show a minimum test midpoint (IC50 value) of 0.1 ± 0.01 µg/l (R1) and 0.2 ± 0.02 µg/l (R2) and a working range of 0.005 to 150 µg/l (R1) and 0.007 to 200 µg/l (R2), which corresponds to more than four orders of magnitude for both. This is quite remarkable for a competitive immunoassay, which is often believed to have a narrow dynamic range. The limit of detection was calculated to 0.6 ng/l (R1) and 1.5 ng/l (R2), which is up to 100 times improvement in relation to the assay of Zeck et al. (1999) on the basis of a monoclonal antibody. The excellent selectivity of the polyclonal antibodies was comprehensively examined by determining the cross-reactivity to common explosives and other nitroaromatics including nitro musk components. The widely held belief that polyclonal antibodies generally display higher cross-reactivities than monoclonals could be disproved.
A series of new epoxide-based monoliths is synthesized by self-polymerization of polyglycerol polyglycidyl ether as porous support for affinity chromatography. Porosity and mean pore sizes are investigated as a function of the porogen ratio and analyzed by mercury porosimetry. The morphologies are visualized by environmental scanning electron microscope. With a particularly rigid monolith prepared with 75 vol% porogen (66% porosity and 12 µm mean pore size), a capillary column (0.5 mm ID) is prepared and directly functionalized with recombinant protein A to extract immunoglobulin G from rabbit serum.
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.