Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (70)
Sprache
- Englisch (68)
- Deutsch (1)
- Mehrsprachig (1)
Referierte Publikation
- ja (70) (entfernen)
Schlagworte
- ELISA (11)
- Affinity chromatography (6)
- Lab-on-a-chip (6)
- Mass spectrometry (6)
- Nitrotyrosine (6)
- Antibody (5)
- Fluorescence (5)
- Immunoassay (5)
- LC-MS/MS (5)
- Tyrosine (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (39)
- 1.5 Proteinanalytik (39)
- 1.1 Anorganische Spurenanalytik (6)
- 1.9 Chemische und optische Sensorik (6)
- 6 Materialchemie (6)
- 6.3 Strukturanalytik (5)
- 1.8 Umweltanalytik (4)
- 1.4 Prozessanalytik (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
- VP Vizepräsident (2)
Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody.
The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters.
Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LCMS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques
(2012)
The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions.
A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications.
Aflatoxins, a group of structurally related mycotoxins, are well known for their
toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein
conjugates are needed for diverse analytical applications. This work describes a reliable
and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and
characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine
serum albumin conjugates were prepared and characterised by UV absorption and
MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens
for the generation of aflatoxin selective antibodies with novel specificities.
A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including top cover to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 µL of sample and flow-rates of 110150 µL min-1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L-1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible.
Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure).
An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable.
High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples.