Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (88)
- Zeitschriftenartikel (64)
- Beitrag zu einem Tagungsband (52)
- Beitrag zu einem Sammelband (9)
- Handbuch (5)
- Buchkapitel (3)
- Forschungsbericht (3)
- Sonstiges (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
- Posterpräsentation (1)
Sprache
- Deutsch (116)
- Englisch (110)
- Mehrsprachig (1)
Schlagworte
- Pool fire (16)
- Organic peroxides (14)
- CFD (13)
- CFD simulation (11)
- SADT (11)
- Organic peroxide (10)
- Ammoniumnitrat (9)
- DTBP (9)
- Safety distances (9)
- Explosion (8)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (88)
IGUS is the International Group of Experts on the Explosion Risks of Unstable Substances. Today, the aim of the group is to exchange information on the behavior of unstable substances and to improve safety in production, storage, transport, and use of these substances. Full members of IGUS work for governments and independent research organizations. Experts from industry can and do attend meetings by invitation. IGUS's 50th anniversary in 2012 gives reason to have a closer look at the questions of how IGUS came to be, what IGUS's aims and objectives were, and how it is organized and working today.
Ziel des F&E-Vorhabens des GSBL (BAM Vh 2520) war die Erarbeitung von Datensätzen auf der Grundlage bereits bestehender Staubdaten (für Datenbasis siehe Abschnitt 4) und die Übergabe der erarbeiteten Datensätze in elektronischer Form an den GSBL bis spätestens 31.05.2011. Der entsprechende Forschungs- und Entwicklungsvertrag trat am 01.08.2009 in Kraft.
Für die Erarbeitung der Datensätze mussten neuartige Konzepte entwickelt werden (siehe Abschnitt 3.5; Abschnitt 3.3 gibt eine Einführung in das Staub-Fachgebiet und behandelt die Besonderheit von Stäuben). Aufgrund von Schwierigkeiten bei der Auswertung und bei der Zusammenstellung der Daten, die erst im Verlaufe des Projekts erkannt wurden, hat es beträchtliche Verzögerungen bei der Erstellung der Datensätze gegeben. Dies führte zu der Feststellung, dass eine Laufzeitverlängerung des Projekts notwendig war. Im Mai 2011 wurde daher ein entsprechender Antrag beim Auftraggeber gestellt. Der Antrag auf kostenneutrale Laufzeitverlängerung führte schließlich zu einer Änderung des ursprünglichen Forschungs- und Entwicklungsvertrags. Der Änderungsvertrag sah eine Verlängerung des Projekts bis zum 30.04.2012 vor.
Um die Datensätze im GSBL abbilden zu können, war es auch erforderlich, eine adäquate Datenstruktur zu entwerfen und diese im GSBL zu implementieren. Die Bekanntgabe der zur Abbildung der Datensätze notwendigen Struktur erfolgte am 11.01.2011 per E-Mail (EXCELDatei gsbldbdir3_23_0029)2. Veränderungen bzw. Präzisierungen dieser Datenstruktur wurden dem GSBL am 19.01.2011 und am 28.01.2011 mitgeteilt, ebenfalls per E-Mail3. Am 19.10.2011 erfolgte eine weitere Änderung, die die sogenannte Nachschlagetabelle betrifft: Der Textinhalt der Tabelle T_STAUBM lautet nun "Auswertung vorhandener Datenkollektive durch Experten-Team." (ursprünglicher Wortlaut: "Auswertung vorhandener Datenkollektive durch Experten"). Die Änderung geht auf einen Wunsch des GSBL-Begleitkreises zurück, der am 07.10.2011 auf der in der BAM stattgefundenen Besprechung vorgebracht wurde.
Organic peroxides are capable to form fireballs with explosive violence. Only fireball models for liquid hydrocarbon fuels are available for the assessment of the thermal radiation properties. Because the development of such fireballs usually differ from those of organic peroxides the properties need to be characterized by modified equations. In this study liquid organic peroxide fireballs from 16 kg to 155 kg substance masses are characterized and compared to selected existing correlations. Flame characteristics and irradiances are measured with infrared cameras and heat flux sensors. All fireballs are consequences of simulated worst case scenarios where filled steel drums are engulfed by fire with varying heat impact. The differences of the given semi-empirical equations and the presented experimental work are explained. A new model is proposed for organic peroxide fireballs by modifying the constants of the known equations. The thermal radiation impact and safety distances are calculated and compared.
The thermal radiation impact of organic peroxide fireballs is experimentally assessed using an infrared camera. Fireballs are generated while liquid peroxide filled steel drums are subjected to gas burner fire at different heating rates. Three large burning clouds are observed with varying flame characteristics. Thermal radiation properties are assessed by infrared images with the presented methods. Despite of the two-dimensional temperature fields, the flames are treated and characterized as three-dimensional objects. Fireball diameters and heights are calculated based on a representing radiating sphere with the same cloud volume. By the use of the solid flame model and assumptions for emissivity and transmissivity, heat fluxes and thermal radiation doses against distance are predicted. Thermal safety distances are presented based on the maximum irradiance and the allowed exposure time. The validation of the maximum and time-dependent radiation fields is achieved through heat flux sensors in varying distances to the fireball. The results prove the use of an infrared camera and a volume based size calculation to fully assess the thermal radiation hazards of fireballs.
Auswirkungen hoher thermischer Belastungen auf flüssige organische Peroxide in Metallbehältern
(2018)
Im Gegensatz zu thermisch instabilen Kunststoffverpackungen garantieren Metallbehälter auch bei hoher thermischer Belastung, beispielsweise durch ein Schadenfeuer, einen stetigen Wärmeeintrag. Ist ein flüssiges organisches Peroxid enthalten, wird durch die Wärme eine sich selbst-beschleunigende exotherme Zersetzung initiiert. Das mit der Entzündung der Zersetzungsgase entstehende Feuer brennt durch den kontinuierlichen äußeren Wärmeeintrag heftiger als dies bei Poolfeuern organischer Peroxide zu beobachten ist. Aufgrund des definierten Einschlusses einer Metallverpackung kann die Zersetzung explosionsartig ablaufen und zur Ausbildung ein- und mehrfacher Feuerbälle führen. Auswirkungsbetrachtungen eines mit flüssigem organischen Peroxid befüllten und von außen befeuerten 220 Liter Stahlfasses wurden anhand zahlreicher Versuche mit unterschiedlichen Aufheizmethoden durchgeführt und sowohl die ermittelten Abbrandraten als auch die gemessenen thermischen Strahlungsbelastungen mit denen eines Poolfeuers verglichen. Die Analyse des Gefahrenpotentials unterschiedlich großer Feuerbälle führte schließlich zur Entwicklung eines ersten semi-empirischen Modells zur Abschätzung des Durchmessers und der Abbranddauer von Feuerbällen organischer Peroxide. Daraus ergibt sich die Möglichkeit der Berechnung notwendiger thermischer Sicherheitsabstände.
Spiel mit dem Feuerball
(2018)
In der Regel verbrennen organische Peroxide (OP) aufgrund ihrer Eigenschaften noch viel heftiger als Flüssigkohlenwasserstoffe. Ein anderes Verhalten wird auch bei der Entstehung und dem Abbrand von Feuerbällen beobachtet. Anhand von Großversuchen an 220-Liter-Stahlfässen wird das Verhalten von OP-Feuerbällen am Beispiel von Di-tert-butyl Peroxid (DTBP) untersucht. Bei der Simulation unterschiedlicher Worst-Case-Szenarien, d.h. unterschiedlicher Außenfeuer, entstehen aufgrund der Selbstzersetzungsprozesse des Peroxids unterschiedlich große, sich explosionsartig ausbildende Feuerbälle. Durch die Charakterisierung u.a. mittels Wärmebildtechnik konnten neue semi-empirische Ansätze für Berechnung der Wärmestrahlung von DTBP-Feuerbällen entwickelt werden. Diese helfen angemessene Schutz- und Sicherheitsabstände im Vorfeld für Produktions- und Verarbeitungsbetriebe zu bestimmen.
Das Abbrandverhalten und die thermische Strahlung von Poolfeuern organischer Peroxide (OP) wurden bereits in der Vergangenheit ausführlich untersucht. Dabei ergaben sich zum Teil erhebliche Unterschiede hinsichtlich der Abbrandraten, Temperaturen, Strahlungsintensitäten und Flammenlängen im Vergleich zu flüssigen Kohlenwasserstoffen. Das größere Gefahrenpotenzial von OP führt zu strikteren Sicherheitsbestimmungen für Lagerung und Transport. Da das Gefahrenpotenzial maßgeblich von den tatsächlich auftretenden Szenarien abhängt, ist eine Bewertung solcher Ereignisse unumgänglich um nachhaltig die Gesundheit von Mensch und Umgebung zu sichern. Ein Metallfass, gefüllt mit 200 Litern DTBP (Di-tertiär-butylperoxid), wurde auf dem Testgelände Technische Sicherheit der BAM einem Außenfeuer ausgesetzt. Durch den starken Wärmeeintrag erhöht sich die Massenabbrandrate des Peroxids um ein Vielfaches und das Fass entleert sich schließlich unter Ausbildung mehrerer Feuerbälle. Die Flammengröße, Flammentemperatur und damit die thermische Strahlung überschreiten die der gewöhnlichen OP-Poolfeuer. Die resultierenden höheren Sicherheitsabstände sind abschließend berechnet.