Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (54) (entfernen)
Schlagworte
- ICP-MS (6)
- Reference material (6)
- HR-CS-MAS (4)
- AAS (3)
- CRM (3)
- Cadmium (3)
- Certified reference material (3)
- Graphite furnace (3)
- ICP-OES (3)
- Lithium (3)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (23)
- 1.6 Anorganische Referenzmaterialien (21)
- 1.7 Organische Spuren- und Lebensmittelanalytik (5)
- 1.1 Anorganische Spurenanalytik (4)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 1.2 Biophotonik (3)
- S Qualitätsinfrastruktur (3)
- S.1 Qualität im Prüfwesen (3)
- 1.3 Instrumentelle Analytik (2)
Paper des Monats
- ja (1)
A method, based on electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICP OES), has been optimized for direct solid sampling analysis of soda-lime glass - the most common type of industrially manufactured glass. This method allows fast and reliable quantification of the main elements - Al, Ca, K, Mg, Na, and Si - and trace elements - As, Ba, Cd, Ce, Co, Cr, Cu, Fe, Mn, Mo, Ni, (P), Pb, Sb, (Se), Sn, Sr, Ti, V, Zn, and Zr. In the presented ETV-ICP OES method, calibration is performed predominantly with matrix-free synthetic samples. This metrological advantage is normally not achieved with direct solid sampling methods and is one of the goals of the present study. In a certification interlaboratory comparison for the soda-lime glass CRM BAM-S005c, 2 out of 16 laboratories employed the ETV-ICP OES method. An improved analytical performance was obtained compared with the results of laboratories that used conventional liquid ICP OES. For both methods, the average relative deviations between the laboratory results and certified values as well as the average values of relative standard deviation were with a few exceptions <10%, in most cases even <5%, which indicated high trueness and precision.
A 9Be-solution has been chemically prepared from phenakite (Be2SiO4) mineral grains as commercial 9Be-solutions are too high in long-lived 10Be. The solution is intended to be used as a carrier for radiochemical separation of 10Be to be measured by accelerator mass spectrometry (AMS). Thus, accurate data of the 9Be-concentration of this solution is essential to guarantee for high-accuracy 10Be data in the future. After devastating preliminary results (~8 % standard deviation), eight laboratories finally produced twelve individual results by four different analytical methods. A certain lab and method bias might be identified by sophisticated statistical evaluation. Some laboratories also (grossly) underestimate their uncertainties. Thus, the simple weighted mean of this round-robin exercise needed to be corrected by introducing additional allowances (Paule-Mandel-approach). The final result has been calculated to (2,246 ± 11) µg 9Be/(g solution) with a reasonably low weighted standard deviation of 0.49 %. The maximum deviation of a single lab value from the weighted mean is 2.4 % when removing one Grubbs outlier (11 % off from the mean) from the data set. As 10Be-data, which is usually calculated from measured 10Be/9Be by AMS and stable 9Be, cannot be more accurate than the determined 9Be-concentration, it seems highly advisable to establish or improve quality assurance by having self-made carrier-solutions analysed at more than a single lab and regularly taking part in round-robin exercises.
An intercomparison study of analytical methods for the determination of magnesium in low alloy steel
(2012)
In an intercomparison study three low alloy steel materials were analyzed on their content of the trace element Mg, and five different analytical techniques were used, namely spark-OES, inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma time of flight mass spectrometry (ICP-TOFMS), inductively coupled plasma quadrupole mass spectrometry (ICP-QMS), and glow discharge mass spectrometry (GD-MS). Solid steel discs were used for analysis with spark-OES and GD-MS. For the analyses with ICP-OES, ICP-TOFMS, and ICP-QMS steel chips were wet-digested in aqua regia, and the wet-digestion was performed either in polypropylene tubes placed in a heating block or in Teflon pressure vessels using a microwave assisted system. The Mg concentrations obtained for the three steel materials were: 2.0, 2.8, and 10.3 µg g-1, respectively, and the spread in results was acceptable, giving RSD values in the range of 2030%.
The capabilities of National Metrology Institutes (NMIs) and selected outside expert laboratories of determining the mass fractions of the main and minor elements Cu, Pb, Sn, Fe, and Ni in a lead-containing brass were assessed. This pilot study P76 was organized as an activity of the Inorganic Analysis Working Group of CCQM and was piloted by the Federal Institute for Materials Research and Testing (BAM). In total 12 laboratories (four NMIs and eight outside labs) submitted results, some of them more than one set of results per element. The laboratories were free to choose any analytical method they wanted to use for the analysis. Consequently various methods of measurement were employed: inductively coupled plasma optical emission spectrometry (ICPOES), inductively coupled plasma mass spectrometry (ICPMS), instrumental neutron-activation analysis (INAA), titrimetry, flame atomic-absorption spectrometry (FAAS), spectrophotometry (MAS), electrogravimetry, and gravimetric analysis. After testing for homogeneity within BAM, a certified reference material of lead-containing brass was used as test sample without informing the participants about the source of the material. The agreement of the results for all elements investigated was acceptable and mean values calculated from the results of all participants were close to the certified mass fractions of the CRM used as test sample. No statistically significant differences between the results of the NMIs and those of the non-NMIs could be observed.
Lanthanide-based, spectrally shifting, and multi-color luminescent upconverting nanoparticles (UCNPs) have received much attention in the last decades because of their applicability as reporter for bioimaging, super-resolution microscopy, and sensing as well as barcoding and anti-counterfeiting tags. A prerequisite for the broad application of UCNPs in areas such as sensing and encoding are simple, robust, and easily upscalable synthesis protocols that yield large quantities of UCNPs with sizes of 20 nm or more with precisely controlled and tunable physicochemical properties from lowcost reagents with a high reproducibility. In this context, we studied the reproducibility, robustness, and upscalability of the synthesis of β-NaYF4:Yb, Er UCNPs via thermal decomposition. Reaction parameters included solvent, precursor chemical compositions, ratio, and concentration. The resulting UCNPs were then examined regarding their application-relevant physicochemical properties such as size, size distribution, morphology, crystal phase, chemical composition, and photoluminescence.
Based on these screening studies, we propose a small volume and high-concentration synthesis approach that can provide UCNPs with different, yet controlled size, an excellent phase purity and tunable morphology in batch sizes of up to at least 5 g which are well suited for the fabrication of sensors, printable barcodes or authentication and recycling tags.
Für den Einsatz in der Funkenemissionsspektrometrie und Röntgenfluoreszenzanalyse hat die Bundesanstalt für Materialforschung und -prüfung (BAM) das zertifizierte Referenzmaterial (ZRM) ERM-EB393a für die Analyse von bleifreiem Messing (CuZn21Si3P) herausgegeben. Zertifiziert wurden die Massenanteile der Legierungselemente Kupfer, Silicium und Phosphor sowie der Spuren Blei, Eisen, Zinn, Aluminium, Chrom, Mangan, Nickel, Arsen und Cadmium. Die Charakterisierung des ZRM erfolgte nasschemisch im Ringversuch mit erfahrenen Laboratorien aus der Nichteisenmetallindustrie.
The key comparison CCQM-K33 was organized by the Inorganic Analysis Working Group of the CCQM to test the abilities of the national metrology institutes to measure the mass fractions of minor elements in steel. Elements to be analysed were Cr, Mn, Ni and Mo in low alloy steel. The National Metrology Institute of Japan (NMIJ), the National Institute of Standards and Technology (NIST) and the Federal Institute for Materials Research and Testing (BAM) acted as the coordinating laboratories. The participants used various measurement methods, though many of them used ICP-AES. Generally speaking, the agreement of the results was very good for each measurand.
The certification of a boron carbide reference material for chemical composition is described. The mass fractions of 16 elements and two boron species are certified in an international interlaboratory comparison with 35 participating laboratories from six different countries. Beside chemical characterization the certification process includes homogeneity and stability testing of the candidate material boron carbide (type F360, 305M422). Details of the analytical methods used for chemical characterization and of the calculation of the uncertainties of the certified mass fractions are given. The new reference material ERM®-ED102 with certified mass fractions of 18 parameters (elements and species) and of the amount fraction of the isotope 10B is a valuable tool for laboratories working in the field of advanced ceramic materials analysis to improve their analytical results.