Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (20)
- Vortrag (4)
- Posterpräsentation (4)
- Corrigendum (1)
Schlagworte
- Nanoparticle (6)
- Quantum dot (5)
- Fluorescence (4)
- Quantum yield (4)
- Extracellular vesicles (EV) (3)
- Photoluminescence (3)
- Reference materials (3)
- Dye (2)
- EMPIR 18HLT01 MetVesII (2)
- Flow cytometry (FCM) (2)
Organisationseinheit der BAM
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (4)
Organic and inorganic nanoparticles (NPs) are increasingly used as drug carriers, fluorescent sensors, and multimodal labels in the life and material sciences. These applications require knowledge of the chemical nature, total number of surface groups, and the number of groups accessible for subsequent coupling of e.g., antifouling ligands, targeting bioligands, or sensor molecules. To establish the concept of catch-and-release assays, cleavable probes were rationally designed from a quantitatively cleavable disulfide moiety and the optically detectable reporter 2-thiopyridone (2-TP). For quantifying surface groups on nanomaterials, first, a set of monodisperse carboxy-and amino-functionalized, 100 nm-sized polymer and silica NPs with different surface group densities was synthesized. Subsequently, the accessible functional groups (FGs) were quantified via optical spectroscopy of the cleaved off reporter after its release in solution. Method validation was done with inductively coupled plasma optical emission spectroscopy (ICP-OES) utilizing the sulfur atom of the cleavable probe. This comparison underlined the reliability and versatility of our probes, which can be used for surface group quantification on all types of transparent, scattering, absorbing and/or fluorescent particles. The correlation between the total and accessible number of FGs quantified by conductometric titration, qNMR, and with our cleavable probes, together with the comparison to results of conjugation studies with differently sized biomolecules reveal the potential of catch-and-release reporters for surface analysis. Our findings also underline the importance of quantifying particularly the accessible amount of FGs for many applications of NPs in the life sciences.
Core–shell nanoparticles (CSNPs) have become indispensable in various industrial applications. However, their real internal structure usually deviates from an ideal core–shell structure. To control how the particles perform with regard to their specific applications, characterization techniques are required that can distinguish an ideal from a nonideal morphology. In this work, we investigated poly(tetrafluoroethylene)–poly(methyl methacrylate) (PTFE–PMMA) and poly(tetrafluoroethylene)–polystyrene (PTFE–PS) polymer CSNPs with a constant core diameter (45 nm) but varying shell thicknesses (4–50 nm). As confirmed by transmission scanning electron microscopy (T-SEM), the shell completely covers the core for the PTFE–PMMA nanoparticles, while the encapsulation of the core by the shell material is incomplete for the PTFE–PS nanoparticles. X-ray photoelectron spectroscopy (XPS) was applied to determine the shell thickness of the nanoparticles. The software SESSA v2.0 was used to analyze the intensities of the elastic peaks, and the QUASES software package was employed to evaluate the shape of the inelastic background in the XPS survey spectra. For the first time, nanoparticle shell thicknesses are presented, which are exclusively based on the analysis of the XPS inelastic background. Furthermore, principal component analysis (PCA)-assisted time-of-flight secondary-ion mass spectrometry (ToF-SIMS) of the PTFE–PS nanoparticle sample set revealed a systematic variation among the samples and, thus, confirmed the incomplete encapsulation of the core by the shell material. As opposed to that, no variation is observed in the PCA score plots of the PTFE–PMMA nanoparticle sample set. Consequently, the complete coverage of the core by the shell material is proved by ToF-SIMS with a certainty that cannot be achieved by XPS and T-SEM.
Immunoassays are an important field of in vitro diagnostics, as they allow for a fast and highly sensitive detection of many biologically and diagnostically relevant analytes such as proteins, hormones, and pharmaceuticals. Fluorescence immunoassays (FIA), where the antibodies and/or antigens are labeled with luminescent reporters, can be easily read out directly by measuring the intensity, decay time, or polarization of the emitted light. Moreover, FIA enable the simultaneous detection of different analytes within a single sample (multiplexing) and are particularly suited for point-of-care (POC) diagnostics and high throughput screening (HTS). The application of luminescent nanoparticles as reporters in FIA could further improve assay sensitivity, as several 100 to 1000 luminophores can be incorporated or attached to such nanoscale carriers, thereby amplifying their absorption and/or emission signals simply by increasing the number of dye molecules.
Although dye-loaded polymeric and silica nanoparticles have been increasingly used as reporters in immunoassays, achievable signal amplification factors related to the use of particle reporters are still difficult to predict and quantify, which also hampers the comparability of different nanoscale reporters. To overcome this challenge, we performed a systematic comparison of spectroscopically and analytically well characterized particle labels in a homogeneous sandwich immunoassay format for the detection of the common inflammation biomarker C-reactive protein (CRP). Hereby, we studied the influence of particle parameters like size, surface chemistry, and dye loading concentration for different dye classes, i.e. organic dyes and metal ligand complexes, varying in their signal-relevant spectroscopic properties (molar absorption coefficients, photoluminescence quantum yields, Stokes shifts, and emission decay times), for different detection schemes (direct read-out vs. dye extraction). The emitters applied were chosen to be commercially available for a reasonable price, to absorb between 400 nm and 450 nm, and to emit in the visible region, as these parameters are accessible with most established microplate readers. Based upon our findings, we highlight the advantages and limitations of nanoscale reporters with respect to the choice of suitable particles, encoding dyes, and detection strategies, and compare the achievable sensitivities and dynamic ranges for our CRP model immunoassay.
The syntheses, structures, and photophysical properties of two new zinc(II) complexes bearing the tridentate N,N′-dimethyl-N,N′-dipyridin-2-ylpyridine-2,6-diamine (ddpd) ligand are presented. Structural investigations through single-crystal X-ray diffractometry, NMR spectroscopy, and density functional theory calculations revealed a diverse coordination behavior that depends on the counterion. Spectroscopic (UV/Vis and emission spectroscopy) and theoretical techniques (DFT and time-dependent DFT calculations) were employed to explore the photophysical properties of the complexes.
The excitation wavelength (lexc) dependence of the photoluminescence (PL) quantum yield (FPL) and decay behavior (tPL) of a series of CdSe/CdS quantum dot/Quantum rods (QDQRs), consisting of the same spherical CdSe core and rod-shaped CdS shells, with aspect ratios ranging from 2 to 20 was characterized. lexc between 400–565 nm were chosen to cover the first excitonic absorption band of the CdSe core material, the onset of absorption of the CDs shell, and the region of predominant shell absorption. A strong lexc dependence of relative and absolutely measured FPL and tPL was found particularly for the longer QDQRs with higher aspect ratios. This is attributed to combined contributions from a length-dependent shell-to-core exciton localization efficiency, an increasing number of defect states within the shell for the longest QDQRs, and probably also the presence of absorbing, yet non-emitting shell material. Although the FPL values of the QDQRs decrease at shorter wavelength, the extremely high extinction coefficients introduced by the shell outweigh this effect, leading to significantly higher brightness values at wavelengths below the absorption onset of the CdS Shell compared with direct excitation of the CdSe cores. Moreover, our results present also an interesting example for the comparability of absolutely measured FPL using an integrating sphere setup and FPL values measured relative to common FPL standards, and underline the Need for a correction for particle scattering for QDQRs with high aspect ratios.
Outer membrane lipopolysaccharides (LPS) play a crucial role in determining attachment behavior and pathogenicity of bacteria. The aim of this study was to develop a simple procedure for anchoring bacterial lipopolysaccharides to polystyrene (PS) microparticles as a model system for in situ attachment studies. By using a swellcapture methodology, commercially available LPS of Pseudomonas aeruginosa (strain ATCC 27316 serotype 10.22) was anchored onto PS microparticles in a proof-of-concept study. A detailed chemical and morphological characterization has proven the success of LPS incorporation. It was shown that the coverage and structure of the LPS film was concentration dependent. The procedure can easily be adapted to LPS of other bacterial strains to generate a synthetic model toolkit for attachment studies.
The importance of microRNA (miRNA) dysregulation for the development and progression of diseases and the discovery of stable miRNAs in peripheral blood have made these short-sequence nucleic acids next-generation biomarkers. Here we present a fully homogeneous multiplexed miRNA FRET assay that combines careful biophotonic design with various RNA hybridization and ligation steps. The single-step, single-temperature, and amplification-free assay provides a unique combination of performance parameters compared to state-of-the-art miRNA detection technologies. Precise multiplexed quantification of miRNA-20a, -20b, and -21 at concentrations between 0.05 and 0.5 nm in a single 150 mL sample and detection limits between 0.2 and 0.9 nm in 7.5 mL serum samples demonstrate the feasibility of both highthroughput and point-of-care clinical diagnostics.
Luminescent lanthanide labels (LLLs) and semiconductor quantum dots (QDs) are two very special classes of (at least partially) inorganic fluorophores, which provide unique properties for Förster resonance energy transfer (FRET). FRET is an energy-transfer process between an excited donor fluorophore and a ground-state acceptor fluorophore in close proximity (approximately 1–20 nm), and therefore it is extremely well suited for biosensing applications in optical spectroscopy and microscopy. Within this cogent review, we will outline the main photophysical advantages of LLLs and QDs and their special properties for FRET. We will then focus on some recent applications from the FRET biosensing literature using LLLs as donors and QDs as donors and acceptors in combination with several other fluorophores. Recent examples of combining LLLs and QDs for spectral and temporal multiplexing from single-step to multistep FRET demonstrate the versatile and powerful biosensing capabilities of this unique FRET pair. As this review is published in the Forum on Imaging and Sensing, we will also present some new results of our groups concerning LLL-based time-gated cellular imaging with optically trifunctional antibodies and LLL-to-QD FRET-based homogeneous sandwich immunoassays for the detection of carcinoembryonic antigen.
Heterogeneous sandwich immunoassays are widely used for biomarker detection in bioanalysis and medical diagnostics. The high analyte sensitivity of the current “gold standard” enzyme-linked immunosorbent assay (ELISA) originates from the signal-generating enzymatic amplification step, yielding a high number of optically detectable reporter molecules. For future point-of-care testing (POCT) and point-of-need applications, there is an increasing interest in more simple detection strategies that circumvent time-consuming and temperature-dependent enzymatic reactions. A common concept to aim for detection limits comparable to those of enzymatic amplification reactions is the usage of polymer nanoparticles (NP) stained with a large number of chromophores. We explored different simple NP-based signal amplification strategies for heterogeneous sandwich immunoassays
that rely on an extraction-triggered release step of different types of optically detectable reporters. Therefore, streptavidinfunctionalized polystyrene particles (PSP) are utilized as carriers for (i) the fluorescent dye coumarin 153 (C153) and (ii) hemin (hem) molecules catalyzing the luminol reaction enabling chemiluminescence (CL) detection. Additionally, (iii) NP labeling with hemin-based microperoxidase MP11 was assessed. For each amplification approach, the PSP was first systematically optimized regarding size, loading concentration, and surface chemistry. Then, for an immunoassay for the inflammation marker C- eactive protein (CRP), the analyte sensitivity achievable with optimized PSP
ystems was compared with the established ELISA concept for photometric and CL detection. Careful optimization led to a limit of detection (LOD) of 0.1 ng/mL for MP11-labeled PSP and CL detection, performing similarly well to a photometric ELISA (0.13 ng/mL), which demonstrates the huge potential of our novel assay concept.