Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (11)
- Posterpräsentation (10)
- Zeitschriftenartikel (3)
- Vortrag (3)
- Sonstiges (1)
Schlagworte
- Electronic nose (6)
- Environmental monitoring (3)
- Nano aerial robot (3)
- Swarm (3)
- Air quality (2)
- Air quality monitoring (2)
- Bauwerksüberwachung (2)
- Chemometric techniques (2)
- Digitalisation (2)
- Environment (2)
- Gas sensing (2)
- Gas sensors (2)
- IMS (2)
- Indoor air quality (2)
- Ionenmobilitätsspektrometrie (2)
- LoRaWAN (2)
- Mobile Robot Olfaction (2)
- Multisensor system (2)
- Smart sensors (2)
- Spectroscopy (2)
- Sprengstoffspurendetektion (2)
- Umweltmonitoring (2)
- VOC (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Aerial robot (1)
- Aerial robot olfaction (1)
- Ammonia (1)
- Anemometer (1)
- Digital Certificates (1)
- Digitalisierung (1)
- ETD (1)
- Embedded sensor (1)
- Emmbedded sensor (1)
- Environmental analysis (1)
- Fluorescence sensor (1)
- Fluoreszenzsensoren (1)
- Flying platforms (1)
- GC-MS (1)
- Gas detector (1)
- Gas standard generator (1)
- Gas tomography (1)
- H2Safety@BAM (1)
- Hydrogen (1)
- Hydrogen technology (1)
- Ion mobility spectrometry (1)
- Localization of gas sources (1)
- Luftfrachtsicherheit (1)
- Metal oxide semiconductor (1)
- Mobile robot olfaction (1)
- Monitoring (1)
- Multigassensoren (1)
- Multivariate analysis (1)
- Outdoor odor emissions (1)
- PLS regression (1)
- Pattern recognition methods (1)
- Permeation (1)
- Phototransistor (1)
- Plume (1)
- Prüfung (1)
- QI Digital (1)
- Quality Infrastructure (1)
- RFID-Sensorsysteme (1)
- Remote gas sensing (1)
- Richtlinie (1)
- Sensorik (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- TD-GC-MS (1)
- TDLAS (1)
- Temperature calibration (1)
- Test gas generation (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thrust (1)
- Tomographic reconstruction of gas plumes (1)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS) (1)
- UAS (1)
- UAV-REGAS (1)
- Urban air monitoring (1)
- Wasserstoff (1)
- Water quality control (1)
- Wind (1)
- Wischprobenahme (1)
- agricultural economy (1)
- binäres Regressionsverfahren (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- pH-Sensor (1)
- poultry odorous air monitoring (1)
- spectroscopy (1)
Organisationseinheit der BAM
- 8.1 Sensorik, mess- und prüftechnische Verfahren (28) (entfernen)
Eingeladener Vortrag
- nein (3)
Leaking methane from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, BAM developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the copter downwash on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile multicopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available systems and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
Emissions of ammonia into the environment are mainly caused by agriculture, but also by combustion processes in waste and by road traffic. Even at low concentrations, this substance is not only an odour nuisance, but also a substance with ecological and climatic relevance. Therefore, BAM tested commercial electrochemical, and metal oxide based sensors, which have limited suitability for measuring in the environmental molar fraction range. Alternatively, own developments for the detection of ammonia in the trace range were implemented, wherein the analyte is measured by changing the fluorescence of a BODIPY dye at 550 nm by means of a portable fluorescence sensor directly from the gas phase. For the calibration of ammonia sensors and measuring instruments, a stationary system based on the mixture of certified test gases from pressure cylinders with calibrated mass flow controllers is available. A test gas generator was developed for on-site calibration and testing of sensors and measuring devices. The generation of ammonia-containing gases in the environmental relevant range of levels below 1000 nmol/mol is carried out by the permeation method according to ISO 6145-10. For the traceability of ammonia, standards are provided and further developed by the National Metrological Institutes and designated institutes. Metrological standards are based on SI units and are a basis for traceability of sensors or gas analysers.
In industrial environments, airborne by-products such as dust and (toxic) gases, constitute a major risk for the worker’s health. Major changes in automated processes in the industry lead to an increasing demand for solutions in air quality management. Thus, occupational health experts are highly interested in precise dust and gas distribution models for working environments. For practical and economic reasons, high-quality, costly measurements are often available for short time-intervals only. Therefore, current monitoring procedures are carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only. Real-time knowledge of contaminant distributions inside the working environment would also provide means for better and more economic control of air impurities. For example, the possibility to regulate the workspace’s ventilation exhaust locations can reduce the concentration of airborne contaminants by 50%.
To improve the occupational health and safety of (industrial) workplaces, this work aims for developing a swarm of gas-sensitive aerial nano robots for monitoring indoor air quality and for localizing potential emission sources.
In this paper, we present an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS) combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. The TDLAS sensor provides integral gas concentration measurements but no information regarding the distance traveled by the laser diode's beam or the distribution of the gas along the optical path. We complemented the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from these integral concentration measurements. To allow for a rudimentary ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present first results showing the 2D plume reconstruction capabilities of the system under realistic conditions.
KonSens (Kommunizierende Sensorsysteme für die Bauteil- und Umweltüberwachung) - Projektergebnisse
(2019)
Im Projekt KonSens werden für die Anwendungsbeispiele bauteilintegrierte Sensorik für Betonkomponenten und mobile Multigassensorik Sensorsysteme in Form von Funktionsmustern entwickelt, validiert und angewendet. Schwerpunkte liegen einerseits in der Detektion und Bewertung von Korrosionsprozessen in Beton und andererseits in der Detektion und Quantifizierung sehr geringer Konzentrationen toxischer Gase in der Luft. Dabei ist die Adaption der sensorischen Methoden aus dem Labor in reale Messumgebungen inklusive geeigneter Kommunikationstechnik ein wichtiger Aspekt.
An equation for wind vector estimation using a multirotor aircraft as a flying anemometer is shown. To compute the wind vector an estimate of the thrust of the aircraft is required, which is related to the rotational speed of the rotors. Hence, a sensing system for the rotational speed using phototransistors is presented.
Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt.
QI-Digital is a joined project aiming at digitalising Quality Infrastructure (QI) processes involving standardization, conformity assessment, accreditation, metrology, and market surveillance [1]. Federal institute of material research and testing (BAM) is working on the creation of a digital calibration certifi-cate (DCC) to achieve digital metrological traceability and conformity assessment. The utilisation of machine readable and executable DCCs in the XML format is demonstrated on an example of a tem-perature measurement at a hydrogen refueling station. The certificates will be retrieved and analysed automatically at a Process Control System or at a Digital Twin.