Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (72)
- Zeitschriftenartikel (41)
- Posterpräsentation (30)
- Vortrag (6)
- Beitrag zu einem Sammelband (3)
Sprache
- Englisch (152) (entfernen)
Schlagworte
- Structural health monitoring (14)
- Gas storage areas (12)
- Membrane-based gas sensing (12)
- RFID sensors (12)
- Subsurface monitoring (12)
- Nano aerial robot (10)
- Mobile Robot Olfaction (9)
- Monitoring (9)
- Smart structures (9)
- Gas source localization (8)
- Swarm (8)
- Drop test (7)
- Gas sensors (7)
- Passive RFID (7)
- Sensors in concrete (7)
- Autonomous micro UAV (6)
- Distributed linear sensor (6)
- Electronic nose (6)
- Embedded sensors (6)
- Gas sensing (6)
- Fluorescence (5)
- Nanocomposites (5)
- Quadrocopter (5)
- Wireless sensors (5)
- Air quality monitoring (4)
- Chemical sensing (4)
- Cone Calorimeter (4)
- Distributed sensor (4)
- Energy harvesting (4)
- Environmental monitoring (4)
- Fire retardancy (4)
- Hazardous scenarios (4)
- Localization (4)
- Localization of gas sources (4)
- Magnetic field (4)
- Mobile robot olfaction (4)
- Mobile sensing system (4)
- TDLAS (4)
- Tomographic reconstruction of gas plumes (4)
- Transmission characteristics (4)
- Tunable Diode Laser Absorption Spectroscopy (TDLAS) (4)
- UAV (4)
- UAV-REGAS (4)
- VOC (4)
- Artificial potential field (3)
- Chemical and wind sensing (3)
- Computed tomography (3)
- Embedded sensor (3)
- Fiber bragg grating (3)
- Gas distribution mapping and gas source localization (3)
- Hopkinson bar (3)
- Indoor air quality (3)
- Linear sensor (3)
- LoRaWAN (3)
- Long term monitoring (3)
- Long-term requirements (3)
- Magnetostrictive metal coating (3)
- Multisensor system (3)
- Particle filter (3)
- Plume tracking (3)
- SHM (3)
- Self-diagnostic fiber optical sensor (3)
- Sensor planning (3)
- Sensor requirements (3)
- Sensors (3)
- Smart sensors (3)
- Soil test field (3)
- Trail detection (3)
- Trail following (3)
- Accelerometer (2)
- Aerial robot (2)
- Aerial robot olfaction (2)
- Air quality (2)
- Ammonia (2)
- Ammonia gas sensor (2)
- Anemometric sensor (2)
- Biologically inspired robots (2)
- CO2 (2)
- Carbon capture and storage (2)
- Chemometric techniques (2)
- Concrete (2)
- Condition monitoring (2)
- Dangerous goods (2)
- Dangerous goods container (2)
- Data fusion (2)
- Data-fusion (2)
- Diagnosis of concrete components (2)
- Digitalisation (2)
- Embedded systems (2)
- Environment (2)
- Fiber Bragg grating (2)
- Fiber optical sensing (2)
- Fibre optical sensing (2)
- Field conditions (2)
- Flame retardance (2)
- Flammability (2)
- Funksensorik (2)
- Gas detection (2)
- Gas dispersion simulation (2)
- Gas distribution modelling (2)
- Gas standard generator (2)
- Gas tomography (2)
- Indoor Localization (2)
- Inertial measurement unit (2)
- Inertial navigation system (2)
- Intumescence (2)
- LOI (2)
- Leak detection (2)
- Leakage (2)
- Magnetostriction (2)
- Membrane-based linear gas sensor (2)
- Miniaturized sensor device (2)
- Mobile Robot (2)
- Monitoring of CO2 (2)
- Monitoring of dangerous goods (2)
- Multi sensor device (2)
- Multi-sensor system (2)
- Multichannel measuring (2)
- NDT Inspection (2)
- Nanocomposite (2)
- Organoclay (2)
- Person tracking (2)
- Plume (2)
- Pump control (2)
- RFID (2)
- RFID based sensors (2)
- RFID-based sensors (2)
- Reactive plume tracking (2)
- Red Phosphorus (2)
- Remote gas sensor model (2)
- Safety management (2)
- Sensor calibration and validation (2)
- Sensornetzwerk (2)
- Setup and Validation (2)
- Spectroscopy (2)
- Standard gas generator (2)
- Strain (2)
- Strukturüberwachung (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Wireless sensor network (WSN) (2)
- Actuators (1)
- Air-based (1)
- Airspeed calibration (1)
- Analysis (1)
- Anemometer (1)
- Anemotaxis (1)
- Auto-validation (1)
- Autonomous UAV (1)
- Autonomous robot (1)
- Behälter (1)
- Berlin Main Station (1)
- Bio-inspired (1)
- Bridge components (1)
- CCS (1)
- Calibration (1)
- Calibration of electrical quantities (1)
- Calibration of force (1)
- Calibration of temperature (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical source localization (1)
- Chemotaxis (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Cone calorimetry (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- DDS (1)
- Data mapping (1)
- Degradation (1)
- Differential displacements (1)
- Digital Certificates (1)
- Digitalisierung (1)
- Discrimination of multiple gas sources (1)
- Distributed multifunctional sensor (1)
- Drop (1)
- Drop tests (1)
- DuraBASt (1)
- Early damage detection (1)
- Early-damage-detection (1)
- Elastoplastic material parameters (1)
- Electronic transport documents (1)
- Embedded (1)
- Embedded system (1)
- Emission control (1)
- Emmbedded sensor (1)
- Environmental analysis (1)
- Epoxide (1)
- Estimation (1)
- Fallprüfung (1)
- Fiber Bragg gratings (1)
- Fiber optic sensing (1)
- Fibre optical sensing (1)
- Finite element methods (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluorescence sensor (1)
- Fluorescent sensor (1)
- Fluoreszenz (1)
- Flying platforms (1)
- Frequency response (1)
- GC-MS (1)
- Gas detector (1)
- Gas distribution mapping (1)
- Gas distribution modeling (1)
- Gas measurement (1)
- Gas storage sites (1)
- Gas-sensitive micro-drone (1)
- Gefahrstoffe (1)
- Guided wave (1)
- H2Safety@BAM (1)
- High Impact testing (1)
- High impact shock application (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Hopkinson Bar (1)
- Hopkinson pressure bar (1)
- Hopkinsonstab (1)
- Humidity sensors (1)
- Hydraulic levelling system (1)
- Hydrogen (1)
- Hydrogen technology (1)
- Impact (1)
- Indentation (1)
- Inertial measurement unit (IMU) (1)
- Intumescent coating materials (1)
- Intumescent coatings (1)
- KonSens (1)
- Lamb wave (1)
- Lamb-waves (1)
- Large scale soil test field (1)
- Laser-based displacement measuring system (1)
- Legged robots (1)
- Measurement (1)
- Measurement uncertainty (1)
- Mesh routing (1)
- Metal oxide semiconductor (1)
- Methane measuring (1)
- Mg(OH)2 (1)
- Micro UAV (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mikrodrohne (1)
- Modeling and simulation (1)
- Moisture (1)
- Moisture measurements (1)
- Monitoring of CO 2 (1)
- Multi-Hop WSN (1)
- Multi-hop (1)
- Multi-sensor (1)
- Multi-sensor device (1)
- Multichannel measuring system (1)
- Multifunctional sensor (1)
- Multihop (1)
- Multirotor aircraft (1)
- Multivariate analysis (1)
- New sensor principles (1)
- Non-destructive evaluation (1)
- Numerical analysis (1)
- Odor localization (1)
- Oil (1)
- Oil spills (1)
- Olfaction (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- Passive sensor interface (1)
- Passive sensors (1)
- Pattern recognition methods (1)
- Permeation (1)
- Permeation method (1)
- Petrol (1)
- Petroleum (1)
- Phototransistor (1)
- Piezoresistive accelerometer (1)
- Piezoresistive accelerometers (1)
- Porous building materials (1)
- Portable (1)
- Prototyp (1)
- QI Digital (1)
- Quadrokopter (1)
- Quadruped robots (1)
- Quality Infrastructure (1)
- Quantification (1)
- Quantification of gas concentrations (1)
- RAM packages (1)
- RFID Sensor systems (1)
- RFID sensors systems (1)
- RFID Sensors systems (1)
- Radioactive (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Real-time (1)
- Reinforced concrete (1)
- Remote gas sensing (1)
- Remote sensing (1)
- Robotik (1)
- SHT (1)
- Safety region model (1)
- Schadensfrüherkennung (1)
- Selective permeability (1)
- Self-diagnosis (1)
- Sensor (1)
- Sensoren (1)
- Sensorik (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Single cable system (1)
- Smartphone (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Spatially distributed monitoring (1)
- Strain measurements (1)
- Structural Health Monitoring (1)
- Structure health monitoring (1)
- Subsurface (1)
- Suche und Lokalisierung von gasförmigen Gefahrstoffquellen (1)
- System adhesive/ strain gauge (1)
- TD-GC-MS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Temperature behavior (1)
- Temperature and Frequency Compensation (1)
- Temperature behavior (1)
- Temperature behavior of a piezoresistive accelerometer (1)
- Temperature calibration (1)
- Temperature characteristics (1)
- Temperature dependent and high dynamic load tests (1)
- Temperaturkompensation (1)
- Test (1)
- Test Streifen (1)
- Test gas generation (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Thrust (1)
- UAS (1)
- UHF antenna (1)
- UL94 (1)
- Ultrasound (1)
- Uncertainty (1)
- Urban air monitoring (1)
- Validation (1)
- Vielkanalmesssystem (1)
- WLAN (1)
- WSN (1)
- Wasserstoff (1)
- Water quality (1)
- Water quality control (1)
- WiFi (1)
- Wind (1)
- Wind estimation (speed and direction) (1)
- Wind speed and direction (1)
- Wind vector (1)
- Wireless mobile sensor device (1)
- agricultural economy (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- poly(propylene) (PP) (1)
- poultry odorous air monitoring (1)
- spectroscopy (1)
- Öl (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (55)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (55)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (9)
- 1 Analytische Chemie; Referenzmaterialien (8)
- 1.9 Chemische und optische Sensorik (7)
- 2 Prozess- und Anlagensicherheit (3)
- 2.1 Sicherheit von Energieträgern (3)
- 8.0 Abteilungsleitung und andere (2)
- 1.2 Biophotonik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (6)
The applicability of three methods developed by finite element analysis (FEM) and proposed in the literature are studied on steel S355. Instrumented indentation tests using spherical indenters of radius 200 and 500 μ m are performed in the macro range at depths of more than 6 μ m. The results of the selected methods are compared with the tensile test. To evaluate the partially strongly varying results, the uncertainties of the calculated strain hardening exponent, n, and yield stress, Y, are estimated. Recommendations for an appropriated procedure of the indentation test are given. The machine compliance and the determination of the zero point of Depth play an essential role. If the certain conditions are considered, the instrumented indentation Tests can be used, in particular for investigations of specimens with inhomogeneous elastoplasticity.
In many cases, science falls back on self-developed prototype systems, which are used and developed for the measurement and execution of the tasks. About 80 % of the development is based on the same hardware design, which is used in only one application scenario and then discarded. For the most part, there are also uncalibrated sensors, since it is costly to calibrate a complicated sensor measurement system or the entire measurement chain since access to the sensor systems is not always available. This paper describes a conceptual design to implement a versatile sensor system with the motivation to fuse the data recording and data reception, which can cover large areas with the help of LoRaWAN (Long Range Wide Area Network) technology. To overcome disadvantages of LoRaWAN, namely the slow data rates, the proposed sensor system can also cover smaller areas with the widespread WiFi technology. An enormous advantage over individual complete systems in the form of a prototype, is the rapid expansion, uncomplicated calibration of the individual sensors and the ecological relief.
A modular design is used, where individual stacks with sensors and peripherals can be added separately. The stacks are standalone low-power systems and can be calibrated, maintained, and replaced separately and do not require the entire measurement chain. The measured and sent values are stored locally on the main stack and sent to the data collector (gateway) and evaluated by means of the automated selection between WiFi and LoRaWAN.
This work focuses on the design and fabrication of low-cost and fast-response of an electronic nose (E-nose) based on semiconductor gas sensors, for discriminating some synthetic gases such as ammonia (NH3), ethanol (C2H5OH), and hydrogen sulfide (H2S). Additionally, the capability of separating different concentration levels of each considered gases was checked. Dataset treatment of E-nose by using Principal Component Analysis (PCA) showed a good discrimination of the different synthetic gases. Furthermore, perfect classification was reached of different concentration levels of the analysed gases by using Discriminant Function Analysis (DFA). In the light of these results, it could be stated that the developed E-nose system constitutes an inexpensive, rapid, simple to use, and efficient tool for synthetic gases detection.
This paper presents first advances in the area of aerial chemical trail following. For that purpose, we equipped a palm-size aerial robot, based on the Crazyflie 2.0 quadrocopter, with a small lightweight metal oxide gas sensor for measuring evaporated ethanol from chemical trails. To detect and localize a 5 cm wide chemical trail, a detection criterion was developed that uses only relative changes in the transient phase of the sensor response. The reduction in signal strength dependence improves the robustness of its application. We tested our setup in first crossing-trail experiments showing that our flying ant robot can correlate an odor hit with the chemical trail within 0.14 m. Principally, this could enable aerial chemical trail following in the future.
Wastewater contains harmful chemicals and heavy metals that are known to cause various environmental and health problems. Therefore, the water quality control using sensitive, simple, fast, accurate, and portable tools is of great importance. This study aimed to evaluate the pollution parameters of wastewaters collected at different treatment stages from a wastewater treatment plant (WWTP) that treats domestic and industrial wastewaters by using an electronic nose (E-nose) and a voltammetric electronic tongue (E-tongue) combined with chemometric techniques. Water and wastewater pollution parameters determination were performed using inductively coupled plasma optical emission spectrometry for the determination of cations, and anions by using ion chromatography. Chemometric techniques, such as Principal Component Analysis (PCA), Discriminant Function Analysis (DFA), Support Vector Machines (SVMs), and Hierarchical Cluster Analysis (HCA), were used to process the E-nose and E-tongue datasets to describe the similarities between the samples. In addition, Partial Least Squares Regression (PLSR) model was constructed using electronic sensing data to simultaneously predict the concentration values of physicochemical parameters. The obtained correlation coefficient, for training and testing sets, is higher than 0.91 for the prediction of the concentration of all physicochemical parameters, except for iron (Fe) which remains 0.84. These results suggest that simple, portable, and inexpensive tools such as electronic nose and tongue are suitable for wastewater analysis.
Die Optimierung und Validierung des digitalen Wasserstofftankstellenmanagements mit Sensortechnologien ist das übergeordnete Ziel des Teilprojekts Digitale Qualitätsinfrastruktur mit Sensortechnologien (QIST) am Use Case H2, im Rahmen der digitalen Qualitätsinfrastruktur (QI digital[1]). Hierfür sollen u.a. Sensornetzwerke mit digital-gestützten Auswertungsstrategien intelligent gestaltet werden (Stichwort KI bzw. digitaler Zwilling). Verschiedene, sich ergänzende Sensoren, Systemkomponenten und KI-Methoden stehen als Bausteine intelligenter Sensorsysteme zur Verfügung, mit dem Zweck, die physikalischen und chemischen Parameter an und in Anlagen umfassend und effizient zu überwachen sowie Fehlfunktionen zuverlässig zu detektieren und zu interpretieren, Abbildung 1.
Konkrete Arbeitsschritte sind, nach dem Aufbau der Versuchsplattform „Wasserstofftankstelle“, die Instrumentierung von Sensorik und deren digitale Integration in das Tankstellenmanagementsystem sowie die Validierung im Realbetrieb. Die somit erzielten Messergebisse sowie die Messunsicherheiten, Historien und Verfahren werden in digitaler Form aufbereitet, gespeichert und fortlaufend in die KI-basierte Datenauswertung einbezogen, inkl. der Anbindung an die metrologische Rückführungskette.
Ziele sind:
• Einführung eines neuen messtechnischen Ansatzes und eines digitalen Zwillings für den Anwendungsfall "Wasserstofftankstelle" auf Basis der H2-Sensorik sowie der Zustandsgrößen Druck und Temperatur
• Qualitätssicherung durch Applikationen zuverlässiger Gassensorik, Manometer und Thermometer sowie KI-Methoden zur Prozesskontrolle und Detektion von Fehlfunktionen
• Nutzung von digitalen Kalibrierscheinen (DCCs) insbesondere für die Messgröße Temperatur zur Realisierung der metrologischen Rückführung in einer digitalen Qualitätsinfrastruktur
QI-Digital is a joined project aiming at digitalising Quality Infrastructure (QI) processes involving standardization, conformity assessment, accreditation, metrology, and market surveillance [1]. Federal institute of material research and testing (BAM) is working on the creation of a digital calibration certifi-cate (DCC) to achieve digital metrological traceability and conformity assessment. The utilisation of machine readable and executable DCCs in the XML format is demonstrated on an example of a tem-perature measurement at a hydrogen refueling station. The certificates will be retrieved and analysed automatically at a Process Control System or at a Digital Twin.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Monitoring and maintenance of civil infrastructure are of great importance, as any undetected damage can cause high repair costs, unintended deadtime, or endanger structural integrity. The inspection of large concrete structures such as bridges and parking lots is particularly challenging and time-consuming. Traditional methods are mostly manual and involve mapping a grid of measurement lines to record the position of each measurement. Current semi-automated methods, on the other hand, use GPS or tachymeters for localization but still require trained personnel to operate. An entirely automated approach using mobile robots would be more cost- and time-efficient. While there have been developments in using GPS-enabled mobile robots for bridge inspection, the weak signal strength in indoor areas poses a challenge for the automated inspection of structures such as parking lots. This paper aims to develop a solution for the automated inspection of large indoor concrete structures by addressing the problem of robot localization in indoor spaces and the automated measurement of concrete cover and rebar detection.
Contamination of natural bodies of water or soil with oils and lubricants (or generally, hydrocarbon derivatives such as petrol, fuels, and others) is a commonly found phenomenon around the world due to the extensive production, transfer, and use of fossil fuels. In this work, we develop a simple system for the on-field detection of total petroleum hydrocarbons (TPHs) in water and soil. The test is based on the measurement of the fluorescence signal emitted by the molecular rotor 2-[ethyl[4-[2-(4-nitrophenyl)ethenyl]phenyl]amino]ethanol (4-DNS-OH). This dye is embedded in a hydrophobic polymeric matrix (polyvinylidene fluoride), avoiding interactions with water and providing a robust support for use in a test strip fashion. Together with the strips, an embedded optical system was designed for fluorescence signal read-out, featuring a Bluetooth low-energy connection to a commercial tablet device for data processing and analysis. This system works for the detection and quantification of TPHs in water and soil through a simple extraction protocol using a cycloalkane solvent with a limit of detection of 6 ppm. Assays in surface and sea waters were conclusive, proving the feasibility of the method for in-the-field operation.
With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders.
Implementation and validation of robot-enabled embedded sensors for structural health monitoring
(2024)
In the past decades, structural health monitoring (SHM) has matured into a viable supplement to regular inspections, facilitating the execution of repair and maintenance work in the early stages of structural damage. With the advent of wireless technologies and advancements in information and communication technologies, civil infrastructure has been increasingly instrumented with wireless sensor nodes to record, analyze, and communicate data relevant to SHM. A promising method for SHM is to embed sensors directly into concrete for recording SHM data from inside structural elements. In this paper, a sensor system for embedment into concrete is proposed, able to assess SHM data recorded from concrete. Power is supplied to the sensors on-demand by quadruped robots, which also collect the SHM data via radio-frequency identification (RFID), providing an automated and efficient SHM process. In laboratory experiments, the capability of the sensor system of automatically collecting the SHM data using quadruped robots is validated. In summary, the integration of RFID technology and robot-based inspection presented in this study demonstrates a vital approach to evolve current SHM practices towards more digitalized and automated SHM.