Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (63) (entfernen)
Schlagworte
- Gas storage areas (9)
- Membrane-based gas sensing (9)
- Subsurface monitoring (9)
- Autonomous micro UAV (5)
- Gas source localization (5)
- Distributed linear sensor (4)
- Distributed sensor (4)
- Electronic nose (4)
- Embedded sensors (4)
- Nanocomposites (4)
- Structural health monitoring (4)
- Chemical and wind sensing (3)
- Computed tomography (3)
- Cone Calorimeter (3)
- Drop test (3)
- Fire retardancy (3)
- Linear sensor (3)
- Nano aerial robot (3)
- Particle filter (3)
- Artificial potential field (2)
- Behälter (2)
- Chemometric techniques (2)
- Cone calorimetry (2)
- Dangerous goods container (2)
- Fallprüfung (2)
- Fiber Bragg grating (2)
- Fibre optical sensing (2)
- Flame retardance (2)
- Flammability (2)
- Fluorescence (2)
- Gefahrstoffe (2)
- Hopkinson bar (2)
- Hopkinsonstab (2)
- Intumescent coatings (2)
- LOI (2)
- Localization (2)
- Magnetic field (2)
- Magnetostriction (2)
- Mobile robot olfaction (2)
- Monitoring (2)
- Monitoring of CO2 (2)
- Multichannel measuring system (2)
- Nanocomposite (2)
- Numerical analysis (2)
- Organoclay (2)
- Quadrocopter (2)
- RFID sensors (2)
- Sensor planning (2)
- Soil test field (2)
- Strain (2)
- Swarm (2)
- TDLAS (2)
- Trail detection (2)
- Trail following (2)
- Vielkanalmesssystem (2)
- Voltammetric electronic tongue (2)
- Wastewater (2)
- Wireless sensors (2)
- Actuators (1)
- Aerial robot (1)
- Aerial robot olfaction (1)
- Airspeed calibration (1)
- Anemometric sensor (1)
- Auto-validation (1)
- Biologically inspired robots (1)
- CCS (1)
- CO2 (1)
- Calibration (1)
- Carbon capture and storage (1)
- Carbon multiwall nanotube (MWNT) (1)
- Cationic polymerisation (1)
- Chemical sensing (1)
- Civil engineering (1)
- Clay (1)
- Collision-free navigation (1)
- Combustion (1)
- Concept (1)
- Cone Caorimeter (1)
- Cone calorimeter (1)
- Container (1)
- Corresponding relative humidity (1)
- Corrosion (1)
- DDS (1)
- Dangerous goods (1)
- Data bus (1)
- Data mapping (1)
- Data-Mapping (1)
- Datenbus (1)
- Degradation (1)
- Discrimination of multiple gas sources (1)
- Early damage detection (1)
- Early-damage-detection (1)
- Elastoplastic material parameters (1)
- Embedded system (1)
- Embedded systems (1)
- Emission control (1)
- Emissionskontrolle (1)
- Energy harvesting (1)
- Environmental analysis (1)
- Epoxide (1)
- Fiber Bragg gratings (1)
- Fiber bragg grating (1)
- Fiber optic sensing (1)
- Fiber optical sensing (1)
- Fibre optical sensing (1)
- Field conditions (1)
- Finite element methods (1)
- Fire testing (1)
- Flame retardancy (1)
- Fluorescent sensor (1)
- Fluoreszenz (1)
- Gas dispersion simulation (1)
- Gas distribution mapping (1)
- Gas distribution mapping and gas source localization (1)
- Gas distribution modelling (1)
- Gas emission (1)
- Gas measurement (1)
- Gas sensing (1)
- Gas sensors (1)
- Gas tomography (1)
- Gas-sensitive micro-drone (1)
- Gasemission (1)
- Gasmessung (1)
- Guided wave (1)
- High Impact testing (1)
- High impact testing (1)
- Hochdynamische Prüfung (1)
- Indentation (1)
- Indoor air quality (1)
- Inertial measurement unit (1)
- Inertial measurement unit (IMU) (1)
- Inertial navigation system (1)
- Intumescence (1)
- Intumescent coating materials (1)
- Lamb wave (1)
- Lamb-waves (1)
- Large scale soil test field (1)
- Leak detection (1)
- Leakage (1)
- Long-term requirements (1)
- Magnetostrictive metal coating (1)
- Membrane-based linear gas sensor (1)
- Metal oxide semiconductor (1)
- Mg(OH)2 (1)
- Micro unmanned aerial vehicle (UAV) (1)
- Micro-drone (1)
- Mikrodrohne (1)
- Mobile Robot Olfaction (1)
- Mobile sensing system (1)
- Modeling and simulation (1)
- Moisture (1)
- Monitoring of CO 2 (1)
- Multichannel measuring (1)
- Multifunctional sensor (1)
- Multivariate analysis (1)
- Non-destructive evaluation (1)
- Oil (1)
- Oil spills (1)
- Outdoor odor emissions (1)
- PCA (1)
- PH monitoring in concrete (1)
- PLS regression (1)
- Passive RFID (1)
- Passive sensors (1)
- Person tracking (1)
- Petrol (1)
- Petroleum (1)
- Plume (1)
- Porous building materials (1)
- Portable (1)
- Quantification (1)
- RFID based sensors (1)
- RFID-based sensors (1)
- Rapid test (1)
- Ratiometric fluorescence (1)
- Reactive plume tracking (1)
- Real-time (1)
- Red Phosphorus (1)
- Reinforced concrete (1)
- Remote gas sensor model (1)
- SHM (1)
- Safety region model (1)
- Self-diagnosis (1)
- Self-diagnostic fiber optical sensor (1)
- Sensor (1)
- Sensor calibration and validation (1)
- Sensor requirements (1)
- Sensoren (1)
- Sensors in concrete (1)
- Single cable measuring (1)
- Single cable serial connection (1)
- Small scale test furnace (1)
- Smart structures (1)
- Smartphone (1)
- Solid phase micro extraction-gas chromatography–mass spectrometry (1)
- Subsurface (1)
- TD-GC-MS (1)
- TG (1)
- TG-FTIR (1)
- TG-MS (1)
- Test Streifen (1)
- Test strip (1)
- Thermal desorption-gas chromatography-mass spectrometry (1)
- Thermal resistance (1)
- Transmission characteristics (1)
- UAV (1)
- UL94 (1)
- Ultrasound (1)
- Uncertainty (1)
- Validation (1)
- Water quality (1)
- Water quality control (1)
- Wind estimation (speed and direction) (1)
- Wind vector (1)
- Windvektor (1)
- Wireless mobile sensor device (1)
- Wireless sensor network (WSN) (1)
- agricultural economy (1)
- embedded sensor (1)
- environment (1)
- fluorescence (1)
- gas analysis (1)
- poly(propylene) (PP) (1)
- spectroscopy (1)
- Öl (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (17)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.9 Chemische und optische Sensorik (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 1.2 Biophotonik (1)
- 8.3 Thermografische Verfahren (1)
- VP Vizepräsident (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (1)
A high-performance fiber Bragg grating-based (FBG) sensor device has been developed for the detection of small magnetic fields. Based on a smart multilayer jacket around the fibre over the physical length of the FBG, magnetic fields generated by rotating machine parts, power generators or power cable can be easily detected, analysed and evaluated. Consequently, this innovative, on-line and non-contact inspection method results in an increase in quality and reliability of high-performing machine parts, devices and cables. The basic physical principle is based on a magnetostrictive multilayer system that strains the high-resolution FBG element in presence of magnetic fields. Subsequently, a fixed relationship between induced magnetic field and wavelength change of the FBG element describes the characteristic sensitivity curve. Intensive tests regarding characterisation of this magnetic field FBG sensor have been carried out and its performance has been evaluated.
A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time.
Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas distribution behavior. In this paper, we briefly describe the setup of a CO2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented.
Gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. A current field study focuses on measuring CO2 concentrations for a spatially distributed monitoring of subsurface CO2 gas storage sites in near real time. A 400 m(2) test site and a corresponding laboratory system were built up to characterize, validate, and optimize the sensor. A calibration routine was developed, which can be applied subsequently to underground installation. First measurement results indicate the potential of the method.
A monitoring method is introduced that creates, in near real-time, two-dimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. A first experimental test indicates the high potential of the proposed method for, e.g., rapid gas leak localization.
A new concept for the self-diagnosis of embedded fiber Bragg grating (FBG) strain sensors was developed, simulated and experimentally tested. This concept is based on a magnetostrictive metallic layer directly coated on the fibre cladding over the grating segment of the FBG sensor, so that an on-demand external magnetic field in a millitesla scale can produce a controllable artificial strain as an indication signal for the remote optical interrogator. The relationship between the pre-defined magnetic field and its induced Bragg wavelength shift characterizes this validation concept. Any deviation of the local bonding state of the interfaces from the initial or/and any change of shear strain transferring mechanism from composite matrix to the optical fibre core will result in alterations in this sensitive relationship, and thus triggers an immediate alert for a further inspection. The finite element method is used to simulate the strain of this configuration as result of different values of the magnetic field in order to optimize the geometrical sensor parameters. The simulations are verified by experiments results. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Damages in infrastructure due to moisture amount to billions of Euros every year. For a more predictive structural health monitoring in civil engineering, the detection and monitoring of hazardous moisture in steel reinforced concrete constructions is of high interest. The sensors have to be wireless, elsewise they weaken the concrete cover of the rebars. The lifetime of such constructions is normally decades, thus the sensors have to be battery-free and fully passive. Considering these requirements, passive RFID-based sensors are developed. Communication and energy supply are realized wireless via the electromagnetic field of a RFID transmitter. The passive RFIDbased sensors are embedded into the concrete to enable the monitoring of moisture transport in porous materials. Results of the hydration process are shown.
An auto-validation tool for the reliability quantification of materials integrated fiber Bragg grating (FBG) strain sensors have been developed and tested. The FBG strain sensor was jacketed with a magnetostrictive layer based on iron-nickel which, when excited by a specific magnetic field, adds an artificial strain to the sensor. The fixed relationship between magnetic induction and wavelength shift of the FBG strain sensor characterizes the bond strength and adhesion between the sensor and the surrounding structure. Due to an easily applicable magnetic field, it is possible to validate the sensor performance in a non-contact, fast way without disturbing the data-acquisition process.
A 400 m2 soil test field with gas injection system was built up, which enables an experimental validation of linear membrane-based gas sensors – a sensor technology which was developed based on the selective permeation of gases through membranes. Several soil watering and injection experiments with carbon dioxide at different days with varying boundary conditions were performed showing that the sensor behaves mostly insensitive to the environmental conditions investigated, i.e., barometric pressure fluctuations, soil temperature, air temperature and humidity, sun duration, and wind speed. Furthermore, depending on water infiltration, a gas phase displacement could be observed in-situ based on the changed measurement signal. The results of the validation experiments highlight the potential of the method for rapid leak detection and localization qualifying the sensor particularly for safety applications, e.g., in underground gas storage areas.
Structural Health Monitoring (SHM) is an important topic for Industry 4.0. More and more systems are embedded in different materials and are connected to each other. To embed sensors for a long time in concrete, an exact preparation is required. In this paper, we identify Radio-Frequency Identification (RFID) as promising technology for monitoring of concrete structures. This paper present the concept for long term monitoring, defines the requirements and shows first development steps, for example, the system design, the possibilities of sensor connection, and an encapsulation for embedding in concrete.
Thermogravimetry (TG), thermogravimetry coupled with mass spectroscopy (TG-MS) and thermogravimetry coupled with Fourier transform infrared spectroscopy (TG-FTIR) were used to characterise the thermo-oxidative behaviour of two intumescent coating materials. The temperature dependence, the corresponding volatile products and the amount of residue of the different processes were determined. Using both TG-MS and TG-FTIR results in an unambiguous interpretation of the volatile products. Characteristics such as the influence of endothermic reactions, the release of non-flammable gases, the dehydrogenation enhancing the char formation and the stability of the cellular char were discussed in detail. It was demonstrated, that TG, TG-MS and TG-FTIR are powerful methods to investigate mechanisms in intumescent coatings and that they are suitable methods in respect to quality assurance and unambiguous identification of such materials.
The influence of different organobentonites on the decomposition and the combustion behaviour of an epoxy resin were examined. The epoxy resin is a cationically polymerised cycloaliphatic epoxy resin flexibilised with poly(tetrahydrofuran) (PTHF), with hydroxyl endgroups. The bentonite was modified with either an ammonium or a phosphonium salt. The thermal decomposition of the PTHF induced by the initiator, used for the cationic polymerisation, did neither take place for the nanocomposite based on the ammonium bentonite nor for that based on the phosphonium bentonite. This improved decomposition characteristic lead to a larger time to ignition for both kinds of nanocomposites compared to the not modified polymer, which is not the case for other polymer/clay nanocomposites described in the literature. The fire behaviour was investigated using limiting oxygen index (LOI), a horizontal burner test and a cone calorimeter. The forced flaming conditions in the cone calorimeter were varied using different external heat fluxes between 30 and 70 kW · m-2. The fire behaviour of the nanocomposites was improved in comparison to the polymer, and phosphonium bentonite was superior to ammonium bentonite. The main mechanism is a barrier formation resulting in a reduction of the fire growth rate, which was more pronounced in the case of high external heat fluxes.
Polymeric intumescent coatings are fire protective materials that increase their thermal resistance when exposed to high temperatures to prevent building structures from damage. The idea of the investigation was to develop a simple test method to determine the time dependent thermal conductivity of intumescent coatings. Therefore steel plates were coated with two different intumescent systems. During cone calorimeter tests the temperature at the back side of the coated plates was measured. These results were used to calculate the time dependent thermal resistance of the protective layer with the simulation program IOPT2D for different external heat fluxes and different layer thickness.
The cone calorimeter has become one of the most important and widely used instruments for the research and development of fire retarded polymeric materials. The paper addresses three important ways in which the principal setup influences the results factors which sometimes do not receive due consideration when drawing conclusions. The paper discusses in detail the impact on cone calorimeter results of the choice of external heat flux, the influence on the peak of heat release rate of sample thickness and thermal feedback from the back of the sample, and the influence on irradiance of the horizontal and vertical distances from the cone heater.
Barrier formation and increasing the melt viscosity are addressed as the two main general fire retardancy mechanisms of polymer nanocomposites. They result in specific impacts on fire properties that consequentially cause varying flame retardancy efficiency in different fire tests. The barrier formation retards mainly flame spread (peak of heat release rate) in developing fires, but does not reduce fire load (total heat evolved), ignitability or flammability (limiting oxygen index, UL 94). Furthermore, this flame retardancy effect increases with increasing irradiation and vanishes with decreasing irradiation. The increased melt viscosity prevents dripping, which is beneficial or disadvantageous depending on the fire test used. In some test, it become the dominant influence, transforming self-extinguishing samples into flammable materials or causing wicking. Advantages and the limits are sketched comprehensively for exploiting the main general fire retardancy mechanisms of polymer nanocomposites. It is concluded that barrier formation and changing the melt viscosity in nanocomposites are not sufficient for most applications, but must be accompanied by additional mechanisms in special systems or in combination with other flame retardants.
A method was developed to assess the heat insulation performance of intumescent coatings. The method consists of temperature measurements using the bench-scaled experimental set-up of a cone calorimeter and finite difference simulation to calculate the effective thermal conductivity dependent on time/temperature. This simulation procedure was also adapted to the small scale test furnace, in which the standard time-temperature curve is applied to a larger sample and thus which provides results relevant for approval. Investigations on temperature and calculated effective thermal conduction were performed on intumescent coatings in both experimental set-ups using various coating thicknesses. The results correspond to each other as well as showing the limits of transferability between both fire tests. It is shown that bench-scaled cone calorimeter tests are a valuable tool for assessing and predicting the performance of intumescent coatings in larger tests relevant for approval. The correlation fails for processes at surface temperatures above 750°C, which are not reached in the cone calorimeter, but are attained in the small scale furnace set-up.
Nanocomposites of bisphenol A polycarbonate with 2, 4, 6, and 15 wt% multiwall carbon nanotubes (MWNT) and their use in fire retardancy are investigated. Their thermal behavior and pyrolysis are characterized using thermogravimetry, differential scanning calorimeter, oscillatory shear rheology, and dynamic mechanical analysis. The flammability is addressed using LOI and UL 94; the fire behavior, with a cone calorimeter using different irradiation. With increasing MWNT content the storage modulus is increased (10-20%) and melt viscosity increases by several orders of magnitude, particularly for low shear rates. The melt flow, dripping, and deformation during fire are hindered, which influences UL 94 and cone calorimeter results. The peak heat release rate is reduced up to 40-50% due to an improved barrier for small amounts (2 wt%) of MWNT and for low irradiation, whereas the effect is reduced for increasing irradiation and nearly vanishes for increasing filling. Adjuvant but also deleterious mechanisms result in the complex dependency on the MWNT content. Significant flame retardancy effects are specific and limited to only some fire properties. This study allows the materials' potential for implementation in different fire scenarios and tests to be assessed and provides insight into active mechanisms.
Contamination of natural bodies of water or soil with oils and lubricants (or generally, hydrocarbon derivatives such as petrol, fuels, and others) is a commonly found phenomenon around the world due to the extensive production, transfer, and use of fossil fuels. In this work, we develop a simple system for the on-field detection of total petroleum hydrocarbons (TPHs) in water and soil. The test is based on the measurement of the fluorescence signal emitted by the molecular rotor 2-[ethyl[4-[2-(4-nitrophenyl)ethenyl]phenyl]amino]ethanol (4-DNS-OH). This dye is embedded in a hydrophobic polymeric matrix (polyvinylidene fluoride), avoiding interactions with water and providing a robust support for use in a test strip fashion. Together with the strips, an embedded optical system was designed for fluorescence signal read-out, featuring a Bluetooth low-energy connection to a commercial tablet device for data processing and analysis. This system works for the detection and quantification of TPHs in water and soil through a simple extraction protocol using a cycloalkane solvent with a limit of detection of 6 ppm. Assays in surface and sea waters were conclusive, proving the feasibility of the method for in-the-field operation.