Filtern
Erscheinungsjahr
- 2019 (21) (entfernen)
Dokumenttyp
- Buchkapitel (21) (entfernen)
Sprache
- Englisch (21) (entfernen)
Referierte Publikation
- nein (21)
Schlagworte
- Concrete (3)
- High temperature (3)
- Stress-strain-relation (3)
- Superplasticizer (3)
- Silica beads (2)
- AFM (1)
- Accelerator (1)
- Archaeometry (1)
- Assessing (1)
- Braking-in-a-turn maneuvers (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (9)
- 3 Gefahrgutumschließungen; Energiespeicher (6)
- 4 Material und Umwelt (5)
- 3.2 Gefahrguttanks und Unfallmechanik (4)
- 7.3 Brandingenieurwesen (3)
- 7.4 Baustofftechnologie (3)
- 3.4 Sicherheit von Lagerbehältern (2)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.5 Röntgenbildgebung (2)
Waste, Evaluation Methods
(2019)
It is difficult to decide which waste management system fulfills best predefined sustainability goals such as maximum materials and energy recovery, least environmental impact, and lowest societal cost. Such decisions are based on many parameters. However, several evaluation methods exist with different scope and output, and the application of one or more evaluation methods provides an objective comparison of alternatives.
The European building sector is moving towards more complex and high-tech building approaches. While focusing on energy efficiency, aspects e.g. occupant health, sustainability and life cycle costing are often neglected. This study highlights the potential of earthen plasters in combination with natural ventilation for low-tech solutions.
The EU funded project [H]house established the outstanding performance of earthen materials in light of hygrothermal and air purifying properties, which were further supported by experimental data from monitoring of naturally ventilated pilot buildings in Berlin. Additionally, [H]house demonstrated through LCC an increased cost efficiency of earth based low-tech solutions in comparison to conventional constructions relying on mechanical ventilation.
Since it was realized that sites contaminated with metals and radionuclides needed treatment, various remediation methods have been and are being developed. Depending on the size of the contaminated site and urgency of intervention, conventional or recently introduced techniques have been used. Conventional techniques include excavation and removal for treatment of soil and contaminants, or the so-called “pump-and-treat” method, in which contaminated groundwater is removed from the ground by pumping and treated in a treatment plant on the surface. It has the advantage of using proven techniques and is easy to control, and the treated groundwater can be reinjected into the ground or discharged in rivers or lakes. Novel methods include permeable reactive barriers, biomineralization, and electrokinetic remediation.
This chapter report the most recent experimental results on mechanical behaviour at high temperature of high-performance concretes. After a short introduction, subsection 5.2 describes the main testing methods that were used in the analysed studies.
Sub-section 5.3 collects and compares; the temperature-dependency of the compressive strength and modulus of elastici1ty of many experimental studies. The influence of parameters such as the initial compressive strength, the type of aggregate, the presence of additions, the W/C ratio, the moishrre content and the way the mechanical test was performed is analysed. Sub-section 5.4 presents the experimental results obtained under a constant temperature, i.e. creep tests at high temperature.
Sub-section 5.5 presents experimental results obtained under increasing temperahrre.
These results allow assessing the free thennal strain of concrete (when no mechanical load is applied) and the so-called "transient the1mal strain". Finally, subsection 5.6 collects and analyses the few results conceming the temperature-dependency of the tensile strength of high-perfo1mance concretes.
Spent fuel storage periods well beyond those originally foreseen are a reality. This publication offers several ideas and approaches that may be considered to address the increasingly longer storage times. The aim is to raise awareness, encourage dialogue and provide ideas on how to manage spent fuel. Key messages include the following:
- Delays in reprocessing or disposal could result in spent fuel being stored for 100 years or longer. Safe, secure and effective storage of spent fuel manages fuel degradation while preserving future fuel cycle options.
- Ageing management programmes apply engineering, operations and maintenance actions to ensure safety is maintained during storage, future handling and transport.
- Site selection and facility and equipment design can significantly reduce the risks and costs of spent fuel storage over longer periods.
- Spent fuel storage configurations can be selected to accommodate uncertain storage periods, to facilitate ageing management and to provide flexibility needed to accommodate the uncertainty of future end points, such as reprocessing or disposal.
- By considering multiple licence renewals, regulatory frameworks can be designed to ensure safe storage until an acceptable end point is achieved.
- Safety can be assured by maintaining shielding, containment, decay heat removal and criticality control. Navigating the complexity of societal beliefs and values, as well as political systems, has proven to be a greater challenge for the management of spent fuel than maintaining its safety and security or addressing the technical and economic aspects.
- Sustainable spent fuel management requires policies and strategies to provide a clear, consistent and stable direction because they drive the need for spent fuel storage as well as the available options and timing for achieving an acceptable end point. Unless States address spent fuel reprocessing and disposal on a sufficient scale to accommodate their spent fuel discharges, then storage for longer and longer periods becomes the de facto end point — which is not considered to be consistent with the responsibility to protect human health and the environment.
An effective, periodic licence renewal process can ensure effective ageing management and strong institutional control. Hence, spent fuel can be safely and securely stored for as long as it may be necessary until transport for reprocessing or disposal. However, the risks and costs of storing the growing inventory of spent fuel will continue to increase; and in the absence of an end point, it will eventually become a significant societal burden.
Properties of interstitial liquid phase in cement paste, including the species and concentrations of polymers and ion etc., play an important role for the rheological properties of cementitious materials. In order to better understand their effect, an inert model substance, spherical silica beads (SBs) with defined surface and granulometry were used in the presence of electrolytes (CaCl2) and/or different polymers, including polycarboxylate superplasticizer (PCE) and polyethylene glycol (PEG). It was found the presence of Ca2+ greatly increases the viscosity and yield stress of silica beads paste (SBP), which is proportional to the [Ca2+]. For the effect of PCE, the addition of PCE is beneficial to the flowability of SBP, but a high dosage of PCE leads to a reversal effect. Furthermore, the yield stress firstly increases and then decreases with increasing [Ca2+] under the same dosage of PCE. The addition of PEG always increases the yield stress of SBP, regardless of the ion concentration and the presence or not of PCE.
The flowability of cement paste is of great importance in today’s construction industry and is influenced by additives such as superplasticizers (SP). One type of SPs are polycarboxylate ether type SPs. These additives electrostatically bind with the negatively charged carboxylic groups at the backbone to the positively charged clinker phases.
To model positively charged clinker phases with adsorbed SP, silicon Wafers are pre-coated with cationic polyethylenimine (PEI) and SP is adsorbed onto the coated surface (Si/PEI/SP). Two different polycarboxylate ether type (PCE) SP are compared – one for ready-mix concrete and one for precast concrete. In this preliminary study the interaction forces between Si/PEI/SP surface and a silica microsphere (colloidal probe) are investigated under mild physico-chemical conditions (pH *6, ion concentration <10−5 M) using Colloidal Probe Atomic Force Microscopy (CP-AFM).
The interaction force between the model surfaces is attractive for low concentration of SP. The force changes from attractive to repulsive by increasing amount of SP. The force upon approach reveals a biexponential behavior. The exponential decay at large and short surface separations are attributed to electrostatic and steric interactions, respectively. The steric forces of the SP for ready-mix concrete show a steeper onset than the SP for precast concrete.
The quantification of these interaction forces will be compared to rheological measurements of similar systems. Furthermore, the parameters will be changed to better approach the conditions in real systems, i.e. higher pH and ionic strength. This helps to understand how the forces on the nanoscale influence the macroscopic rheology.
Braking-in-a-turn maneuvers represent a critical operational condition for any vehicle, due to the associated longitudinal and lateral perturbations to which it is subjected, which maximize the load transfer among the different wheels, and result in vehicle´s poor lateral stability and deficient braking performance.
In this paper, a suspended vehicle supporting a partially filled 10 litter-capacity container, is set on a tilt table at oblique angles, in order to simulate a braking-in-a-turn maneuver. The measurements are assessed in the time and frequency domains, on the basis of the lateral load transfer ratio and the infrastructure fatigue damage. The outputs from the experiment show that the Minimum fill level (one-quarter), generates the larger lateral load transfer (0.45). Such fill level also causes the greatest ratios for the alternate stress over the mean stress on the infrastructure. The spectral analysis reveals the dominance of one of the sloshing frequencies during such combined perturbation condition.
Although concrete itself is not a combustible material, concrete mixtures with high density, such has high-performance concretes (HPCs), are susceptible to significant damage during fires due to explosive spalling. Past research has shown that the inclusion ofpolymer fibres in high density concrete can significantly mitigate this fire damage. The exact mechanisms causing this increased spalling resistance are not yet fully understood, but it is thought that the fibres facilitate moisture transport during fire exposure, which in turn contributes to relief of internal stresses in the spalling-susceptible region. In this study, X-ray Computed Tomography (CT) was applied to observe the interaction between polymer fibres and cracking during thermal exposure. For this purpose, two concrete samples containing different polymer fibre types were subjected to incremental application of a defined thermal exposure. CT images were acquired before and after each thermal exposure and powerful image processing tools were used to segment the various material components. This enabled a detailed analysis of crack formation and propagation as well as the visualization and quantification of polymer fibre characteristics within the concrete. The results demonstrated that the orientation of both fibres and cracks in polymerfibre reinforced concrete tend to be anisotropic. The results also indicated that crack geometry characteristics may be correlated with fibre orientation, with cracks tending to run parallel to fibre beds. Clear quantitative relationships were also observed between heating and increasing cracking levels, expressed in terms of both crack surface area and crack volume.
Although concrete itself is not a combustible material, concrete mixtures with high density, such has high-performance concretes (HPCs), are susceptible to significant damage during fires due to explosive spalling. Past research has shown that the inclusion of polymer fibres in high density concrete can significantly mitigate this fire damage. The exact mechanisms causing this increased spalling resistance are not yet fully under-stood, but it is thought that the fibres facilitate moisture transport during fire exposure, which in turn contributes to relief of internal stresses in the spalling-susceptible region. In this study, X-ray Computed Tomography (CT) was applied to observe the interaction between polymer fibres and cracking during thermal exposure. For this purpose, two concrete samples containing different polymer fibre types were subjected to incremental application of a defined thermal exposure. CT images were acquired before and after each thermal exposure and powerful image processing tools were used to segment the various material components. This enabled a detailed analysis of crack formation and propagation as well as the visualization and quantification of polymer fibre characteristics within the concrete. The results demonstrated that the orientation of both fibres and cracks in polymer-fibre reinforced concrete tend to be anisotropic. The results also indicated that crack geometry characteristics may be correlated with fibre orientation, with cracks tending to run parallel to fibre beds. Clear quantitative relationships were also observed between heating and increasing cracking levels, expressed in terms of both crack surface area and crack volume.