Filtern
Erscheinungsjahr
- 2022 (1505) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (569)
- Vortrag (556)
- Posterpräsentation (165)
- Beitrag zu einem Tagungsband (129)
- Forschungsdatensatz (22)
- Forschungsbericht (19)
- Sonstiges (13)
- Buchkapitel (11)
- Video (5)
- Corrigendum (4)
- Dissertation (4)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (4)
- Monografie (2)
- Beitrag zu einem Sammelband (1)
- Tagungsband (Herausgeberschaft für den kompletten Band) (1)
Sprache
- Englisch (1505) (entfernen)
Schlagworte
- Additive manufacturing (54)
- Corrosion (35)
- Nanoparticles (33)
- Concrete (32)
- Fluorescence (28)
- Hydrogen (26)
- Mechanochemistry (26)
- Ultrasound (26)
- Additive Manufacturing (25)
- Laser beam welding (23)
Organisationseinheit der BAM
- 6 Materialchemie (323)
- 8 Zerstörungsfreie Prüfung (318)
- 1 Analytische Chemie; Referenzmaterialien (252)
- 9 Komponentensicherheit (191)
- 7 Bauwerkssicherheit (155)
- 5 Werkstofftechnik (142)
- 4 Material und Umwelt (122)
- 6.3 Strukturanalytik (107)
- 6.1 Oberflächen- und Dünnschichtanalyse (90)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (87)
Paper des Monats
- ja (20)
Validation of a fast and traceable radiographic scale calibration of dimensional computed tomography
(2022)
A fast and highly precise method of determining the geometrical scale factor of computed tomography (CT) measurements has been validated successfully by Bundesanstalt für Materialforschung und -prüfung (BAM), the Federal Institute of Metrology (METAS) and Physikalisch-Technische Bundesanstalt (PTB) within the scope of AdvanCT (Advanced Computed Tomography for dimensional and surface measurements in industry), a project funded in the European Metrology Programme for Innovation and Research (EMPIR). The method has been developed by PTB and requires only two radiographic images of a calibrated thin 2D standard (hole grid standard) from two opposite directions. The mean grid distance is determined from both radiographs. From this and with the help of the calibration result, the radiographic scale and therefore the voxel size is determined. The procedure takes only a few minutes and avoids a time-consuming CT scan. To validate the method, the voxel sizes determined via this method were compared with voxel sizes determined from CT scans of calibrated objects. Relative deviations between the voxel sizes in the range of 10−5 were
achieved with minimal effort using cone-beam CT systems at moderate magnifications.
Thermal spraying provides a rapid method for additive deposition of various ceramics as electrical insulation in applications where polymers are not suitable. New applications in complex shaped additive manufactured metal parts are emerging for example in large scale electrical devices. Microstructural and dielectric evaluation of coatings is crucial to the employment of such free-form processes. The properties and microstructure of the plasma sprayed alumina coatings are compared with dense reference samples of the same powder produced by spark plasma sintering (SPS). To obtain dense bulk samples from the coarse alumina powder for spray coating, SPS is used.
Samples are fabricated by atmospheric plasma spraying (APS) of commercially available alumina powder (d50 = 33 µm) on copper substrates and by SPS of the same powder. Microstructure and porosity were analyzed by optical microscopy and scanning electron microscopy (SEM). Phase compositions were determined by X-ray diffraction (XRD). Dielectric properties such as DC resistance, dielectric strength, dielectric loss, and relative permittivity were determined according to the standards. The microstructure and dielectric properties of the coating and bulk material are compared to assess whether the coating is suitable for use in electrical insulation application.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is increasingly used to study the distribution of metal-containing drugs, imaging probes and nanomaterials in connection with disease related changes and therapy progress. Additionally, biomolecules can be detected indirectly by using metal-tagged antibodies.
The extracellular matrix (ECM) is, besides the cells, an important component of all body tissues. The macromolecular network of the ECM consists of structural proteins (e.g., collagen, elastin) and proteoglycans composed of highly negatively charged carbohydrates, the glycosaminoglycans (GAGs), which are covalently linked to a protein core. Many diseases, including inflammatory processes and tumors, are associated with characteristic ECM changes at an early stage. Recent studies have shown that contrast agents for magnetic resonance imaging (MRI), which are based on gadolinium containing chelate complexes or iron oxide nanoparticles, can bind themselves to ECM components.
To elucidate the role of GAGs like keratan sulfate (KS) and its modification state in disease, highly specific tools are necessary. As a complement to conventional immunohistochemistry LA-ICP-MS was applied to investigate the distribution of KS in tissue thin sections using a well characterized anti-KS antibody labelled with metal ions. Furthermore, LA-ICP-MS was used for the detection of MRI contrast agents and the identification of their target cells and molecules in tissue samples from animal models, e.g. for cardiovascular diseases. The results show the possibilities of LA-ICP-MS for the elucidation of pathological tissue changes.
Probe diagnostics is used to determine the electron temperature and electron number density in a low pressure inductively coupled plasma (ICP) ignited in the mixture of SiF4, Ar and H2. Emission spectra of mixtures with different stoichiometry of components are investigated and the electron density distribution function (EDDF) is estimated. The optimal conditions for high conversion of SiF4 into Si are found by studying the dependence of the yield of silicon upon the ratio of reagents. The maximum achieved yield of silicon is 85% under the optimal conditions. Based on the analysis of IR and MS spectra of exhaust gases, 5% of initial SiF4 converts into volatile fluorosilanes. A rate of production of Si is 0.9 g/h at the energy consumption 0.56 kWh /g.
Nanoforms with at least one dimension below 100 nm have an important part to play in more and more areas of our daily life. Therefore, risk assessment of these materials is becoming increasingly important. In this context, the European Chemical Agency (ECHA) considered eleven physico-chemical properties as relevant, of which the following six are essential for the registration: chemical composition, crystallinity, particle size, particle shape, surface chemistry and specific surface area. Four of these priority properties can be obtained with electron microscopy and surface analytics like XPS and ToF-SIMS. The reliability of this data must be ensured, especially for their use for grouping and read across approaches. On the other hand, the “reproducibility” crisis has revealed major shortcomings in the reliability of published data.
In a case study, we show how the quality of the data can be ensured by using existing standards and protocols of each step in the workflow of sample characterization. As exemplary samples, two Al-coated TiO2 samples as nanopowders were selected from the JRC repository, capped either with a hydrophilic or a hydrophobic organic ultrathin shell. SEM results provided the size and shape of the nanoparticles, a first overview about the composition was obtained with EDS. XPS and ToF-SIMS supplied the surface chemistry, especially information about the shell and the coating of the particles. Standards and protocols of all steps of the analytical workflow including preparation and data reduction are discussed regarding reliable and reproducible data. Additionally, uncertainties for the different steps are specified.
Only such a detailed description of all these factors allows a comprehensive physico-chemical characterization of the nanoparticles with understanding of their potential risk assessment.
The recent development of x-ray photoelectron spectroscopy using excitation sources different from the usual lab-source Mg Kα and Al Kα and spectrometers with more sophisticated lens systems requires flexible approaches for determining the transmission function. Therefore, the approach using quantified peak areas (QPA) was refined.1 A new algorithm allows a more precise estimation of the transmission function which could be shown by comparing the results obtained with the new version with former calculations. Furthermore, next to the established reference materials Cu, Ag and Au, ionic liquids can be used for estimating the transmission function at beamlines with variable excitation energies. Comparison between the measured and stoichiometric composition shows that a transmission function was determined which allows a reasonable quantification.
microscopy (AFM), or X-ray reflectometry. For the additional determination of thin film composition, techniques like X-ray photoelectron spectroscopy (XPS) or mass spectrometry-based techniques can be used. An alternative non-destructive technique is electron probe microanalysis (EPMA). This method assumes a sample of homogenous (bulk) chemical composition, so that it cannot be usually applied to thin film samples. However, in combination with the thin film software StrataGEM, the thickness as well as the composition of such films on a substrate can be determined.
This has been demonstrated for FeNi on Si and SiGe on Al2O3 film systems. For both systems five samples with different elemental composition and a reference were produced and characterised by Korean research institute KRISS using inductively coupled plasma mass spectrometry (ICP-MS), Rutherford backscattering (RBS), and transmission electron microscopy (TEM). These samples were used for an international round robin test.
In 2021, a new and open-source thin film evaluation programme called BadgerFilm has been released. It can also be used to determine thin film composition and thickness from intensity ratios of the unknown sample and standards (k-ratios).
In this contribution, we re-evaluated the data acquired for the FeNi and SiGe systems using the BadgerFilm software package and compared the resulting composition and thickness with the results of the established StrataGEM software and other reference methods. With the current evaluation, the BadgerFilm software shows good agreement with the composition and thickness calculated by StrataGEM and as the reference values provided by the KRISS.
The mechanical and geometrical properties of impact targets greatly influence the outcome of a drop test. The International Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) as well as ISO 2248 describe the characteristics of impact targets for drop tests of dangerous goods packagings.
According to these regulations, the impact target’s surface needs to be unyielding, under testing conditions non-deformable, flat, and integral with a mass at least 50 times that of the heaviest packaging to be tested. The problem is that many production facilities, especially manufacturers of corrugated fibreboard boxes, do not have their own testing device with the required 50 times mass ratio of the impact target for a regulation compliant drop test during series production. Furthermore, at UN level it is considered necessary to revise these requirements.
In the present paper, the impact target requirements are examined in detail and compared with those in other technical areas (e.g., impact target for container for the transport of radioactive materials). A research method is being developed to investigate the dependency between the mass ratio of the packaging and the target as well as the damage resistance of a drop tested package in relation to specific design characteristics. The results are of high relevance for industry purposes and intended to ensure a uniform level of safety assessment for the mechanical testing of dangerous goods packagings.
The novel lab-based HAXPES spectrometer (ULVAC-PHI Quantes) gives us the possibility to measure XPS at 1486.6 eV (monochromatic Al Kα source) and HAXPES at 5414.9 eV (monochromatic Cr Kα source) on a sample at the same position. The surface analysis with this spectrometer leads to an information depth of about 10 nm for XPS and in comparison, to an analysis of deeper regions of about 30 nm for HAXPES measurements. This method provides a nondestructive way to distinguish between the near-surface region of the nanoparticles and the whole nanoparticle. Additionally, HAXPES gives access to deeper core levels at higher energy.
An application of this technique is presented using nanoparticles. The results shown were obtained with nanoparticles, that were treated differently by means of sterilization for nanosafety (i.e., before studying their toxicity it is important to establish whether nanomaterials are sterile and, if not, to be treated either via microwave or autoclave sterilisation). As a complementary method, the data is compared with SEM and EDX measurements. All methods demonstrate the influence of sterilization. More specifically, these results show that the sterilization step must be considered in the physical-chemical description of the particles for establishing reliable (quantitative structure-activity) relationships.
The Perfectly Matched Layer (PML) method is an efficient approach to imposing radiation conditions at the bounded region of interest in case of wave propagation in unbounded domains. This paper presents and validates 3D FE/PML numerical schemes based on two different PML formulations for homogeneous and inhomogeneous geological media exhibiting discrete or continuous inhomogeneity. In the equation of motion for the PML domain the applied stretching behavior is expressed either as complex material properties or as complex coordinates. Both PML formulations are implemented in the FEM and verified against analytical solutions. Three different types of material inhomogeneity are considered: layered half-space, continuously inhomogeneous half-space with linear velocity profile and continuously inhomogeneous half-space with nonlinear velocity profile. Sensitivity analyses are conducted, and the performance of the developed numerical schemes is investigated taking into account a broad variation of the PML parameters. Recommendations are given for the optimal values of the PML parameters for the case of homogeneous and inhomogeneous geological media.