Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (19760)
- Zeitschriftenartikel (17913)
- Posterpräsentation (6162)
- Beitrag zu einem Tagungsband (5983)
- Beitrag zu einem Sammelband (2316)
- Forschungsbericht (769)
- Sonstiges (390)
- Buchkapitel (355)
- Dissertation (297)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (252)
Sprache
- Deutsch (30449)
- Englisch (23893)
- Mehrsprachig (191)
- Französisch (41)
- Russisch (31)
- Spanisch (21)
- Ungarisch (11)
- Tschechisch (7)
- Italienisch (7)
- Japanisch (5)
Schlagworte
- Korrosion (424)
- Corrosion (411)
- Concrete (389)
- Fluorescence (345)
- Nanoparticles (326)
- Additive manufacturing (291)
- Simulation (256)
- LIBS (250)
- Zerstörungsfreie Prüfung (246)
- XPS (230)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (2242)
- 6 Materialchemie (2196)
- 1 Analytische Chemie; Referenzmaterialien (1781)
- 7 Bauwerkssicherheit (1776)
- 9 Komponentensicherheit (1457)
- 4 Material und Umwelt (1080)
- 5 Werkstofftechnik (1057)
- 3 Gefahrgutumschließungen; Energiespeicher (801)
- 6.3 Strukturanalytik (616)
- 6.1 Oberflächen- und Dünnschichtanalyse (576)
Paper des Monats
- ja (77)
Study of effects of plasma parameters by characterization of pulse plasma deposited organic films
(2003)
Molecular dynamics of 4n-octylcyanobiphenyl in partially filled nanoporous SBA molecular sieves
(2003)
Diamantähnliche Kohlenstoffschichten (DLC) zeichnen sich durch ein sehr günstiges Reibungs- und Verschleißverhalten aus. Auf vielen Werkzeugen und hochbelasteten Bauteilen ist DLC daher bereits erfolgreich im Einsatz. In naher Zukunft wird die Bedeutung dieser Schichten als Oberflächenschutz in tribologischen Systemen weiter ansteigen.
Wie viele Applikationsbeispiele zeigen, ist die Leistungsfähigkeit von DLC als Schicht zur Verringerung von Reibung und Verschleiß zwar groß, weist aber auch Grenzen auf. Vor allem bei höheren Temperaturen (> 300 °C) treten Strukturveränderungen oder sogar Oxidationsvorgänge auf, die auch die tribologischen Eigenschaften der Schichten verschlechtern können.
Reibungs- und Verschleißuntersuchungen (Schwingungsverschleiß) von DLC-Schichten wurden im Temperaturbereich von 25 °C bis 250 °C durchgeführt und zeigen ein schnelleres Durchreiben der Schicht bei höheren Temperaturen. Die Lebensdauer der Schichten wird mit zunehmender Prüftemperatur reduziert. Einsatzgrenzen für DLC-Schichten können abgeleitet werden.
Femtosecond laser pulses are close to industrial use. The advantages of ultrashort laser pulses for micromachining applications especially in the case of dielectric and biological samples down to pulse durations of 5 fs have been established. The current international standards of laser safety are primarily concerned with CW and pulsed lasers down to the nanosecond range. Therefore, human tissue and laser-protection equipment was investigated with respect to its resistance and protection performance for femtosecond laser illumination down to 30 fs. This included filter glasses for laser protection eyewear, polymer and textile materials used in curtains and guards. Bulk absorber filters can provide enough protection against laser radiation, give a sufficiently broad absorption spectrum. Materials are damaged more easily by femtosecond laser radiation. The need for sufficient spectral broadness as well as the different damage thresholds have to be included in international laser safety standards. This work should trigger the development of novel eye-protection devices that are lighter and ergonomically more acceptable than present commercial models.
Molecular dynamics of surface layer in cyanobiphenyl-aerosil systems with high silica density
(2003)
Characterization of technical polymers using liquid chromatography as well as hyphenated techniques
(2003)
Effects of Heat Treatment on the Structure of Thermal Plasma Synthesized SiCN Composite Nanopowders
(2003)
About nanocrystalline Hydroxyapatite and the binding of apatite in bone: a novel NMR perspective
(2004)
The main problem in the certification of pressure-volume curves for the high-pressure range of the mercury intrusion is the fact that the uncertainty of the pressure (x-axis) should not be neglected. Additionally, the use of pressure-volume curves from different laboratories using different apparatus leads to incomparability of these curves and requires a correction. This is known in the statistical literature as warping. The use of point wise intervals causes
difficulties in the interpretation of the results. Such problems have been eliminated in the certification of pressure-volume curves of the new standards ERM®-FD123 and BAM-P124 to BAM-P126. These standards are reference materials for the comparatively low-pressure range of the mercury intrusion method.
The materials BAM-P124 and BAM-P126 are made up as flat membranes. The production of these membranes (a-alumina ceramics) was carried out in the HITK, Hermsdorf, Germany. The long ceramic tape was divided into 50 rectangular tapes. These tapes were sintered. Each of the tapes has been cut in 30 dies, numbered by a laser beam.
Samples were assigned systematically covering all 50 tapes to allow for an optimal modelling of material inhomogeneities.