Application of synchrotron infrared radiation in the study of organic coatings in cross-sections
(2008)
Mechanochemical synthesis of [Zn3(C2O4)3(4,4'-bipy)4] and its reorganization at high temperatures
(2014)
The metal organic layered structure catena-(bis(µ2-4,4'-bipyridine)-tris(µ2-oxalato)-bis(4,4'-bipyridine)-tri-zinc(ii)) ([Zn3(C2O4)3(4,4'-bipy)4]) was synthesized mechanochemically applying three different routes. The synthesis succeeded by i) simultaneously neat grinding the three starting materials zinc acetate dihydrate, oxalic acid dihydrate and 4,4'bipyridine, ii) grinding two compounds and adding the third afterwards, independent of the sequence. The products were characterized using powder X-ray diffraction, Raman spectroscopy, gas adsorption measurements, and scanning electron microscopy. Temperature-dependent synchrotron XRD measurements revealed that the monoclinic structure of [Zn3(C2O4)3(4,4'-bipy)4] rearranges reversibly to a higher ordered orthorhombic structure [Zn(C2O4)(4,4'-bipy)] at high temperatures.
The propagation of synchrotron radiation through nanocapillary structures with channel sizes of 200 nm and periods in the micrometer size has been studied experimentally. It was shown that the propagation through individual capillary channels has a mode formation character. Furthermore it was shown that during the propagation through capillary channels the coherence of synchrotron radiation is partially conserved. Interference of beams propagating through different capillary channels is observed which leads to a periodically modulated distribution of the radiation intensity in a plane far from the exit of the structure. These investigations are of high relevance for the understanding of X-ray transmission through nanocapillaries and the appearance of wave properties at this size scale.
Measurements of ion distributions at a charged solid–liquid interface using X-ray standing waves (XSW) are presented. High energy synchrotron radiation (17.48 keV) is used to produce an XSW pattern inside a thin water film on a silicon wafer. The liquid phase is an aqueous solution containing Br and Rb ions. The surface charge is adjusted by titration. Measurements are performed over a pH range from 2.2–9, using the native Si oxide layer and functional (amine) groups as surface charge. The Debye length, indicating the extension of the diffuse layer, could be measured with values varying between 1–4 nm. For functionalized wafers, the pH dependent change from attraction to repulsion of an ion species could be detected, indicating the isoelectric point. In combination with the measurement of the streaming current, the surface charge of the sample could be quantified.
This study intends to clarify the metal provenance of gold archaeological items using the variation of the Au–Ag ratio and the presence of trace elements as Sn, Sb, Te, and Pb, concentrating on gold Dacian Koson coins, recovered recently. It also extends the area of our investigations to the copper provenance of Bronze Age artifacts—axes, sickles, and celts—found on Romanian territory. The experiments were performed by micro-SR XRF at BESSY Berlin, at the BAM-line facility. Two types of coins (Koson, with and without monogram) were analysed. The conclusions we reached were that most of the monogram coins are made from refined gold (3–5% Ag, less than 0.5% Cu), while the without monogram coins are made from native Transylvanian gold (9–20% Ag, 0.5–2% Cu), of alluvial origin, proved by the presence of Sn, Sb and Te embedded in the gold. The problem of provenance for prehistoric Romanian copper and bronze objects consists in linking their elemental compositional patterns to the ones of the Bronze Age regional mines from Bulgaria, Serbia or Transylvania, most likely used as ore sources for their manufacture. The studied samples present relevant traces of As, Ag, Sb, and Co, suggesting the most probable use of copper from Serbia or northern Bulgaria for their manufacture.
Hydrogen generally causes lattice distortions and phase transformations when introduced into a metallic crystal lattice. For the investigations reported in this contribution, hydrogen thermal desorption analysis has been carried out to observe the influence of hydrogen desorption on the lattice of super martensitic stainless steel during continuous heating. The lattice expansion parameter and the phase transformations have been monitored during the thermal desorption process, and the influence of hydrogen on such characteristics has been evaluated. It was found that hydrogen has a significant influence on both the lattice parameter and on the thermal expansion. However, hydrogen has no influence on phase transformation during thermal desorption. The hydrogen's desorption behavior in this process was also observed and it turned out that hydrogen desorbs in two stages, i.e., firstly diffusible hydrogen and trapped hydrogen afterward.
X-ray topography is a well known imaging technique to characterise strain and extended defects in single crystals. Topographs are typically collected on X-ray films. On the one hand such photographic films show a limited dynamic range and the production of films will be discontinued step by step in the near future. On the other hand new imaging detectors improved for X-ray tomography become more and more attractive even for topography because of increasing resolution, dynamic range, speed and active area. In this paper we report about the upgrade of the TOPOTOMO beamline at the synchrotron light source ANKA, Research Centre Karlsruhe, with a high resolution digital camera for the topography use.
Microstructural aspects of composites such as reinforcement particle size, shape, and distribution play important roles in deformation behavior. In addition, Fe-rich inclusions and porosity also influence the behavior of these composites, particularly under fatigue loading. Three-dimensional (3-D) visualization of porosity and Fe-rich inclusions in three dimensions is critical to a thorough understanding of fatigue resistance of metal matrix composites (MMCs), because cracks often initiate at these defects. In this article, we have used X-ray synchrotron tomography to visualize and quantify the morphology and size distribution of pores and Fe-rich inclusions in a SiC particle-reinforced 2080 Al alloy composite. The 3-D data sets were also used to predict and understand the influence of defects on the deformation behavior by 3-D finite element modeling.