Ultrasonic signal evaluation used to detect temperature changes in a concrete specimen caused by a heating system

  • Ultrasonic measurement evaluation methods have been proven to be effective for detection of subtle changes, caused by temperature, load or moisture. To detect and localize temperature changes, a concrete block of 4 × 5 × 0.8 m3, including a heating cartridge and multiple temperature sensors, has been set up to change the temperature and monitor the temperature distribution in a certain area inside the specimen. An ultrasonic monitoring system with 40 ultrasonic sensors (20 transmitters, 20 receivers, 25 kHz central frequency) has been implemented on the specimen. Data from 400 sensor combinations was collected over the whole period of the experiment in an interval of 30 minutes. Quantitative methods (CodaWave Interferometry and Time of Flight method) were used to evaluate the changes in ultrasonic travel-time caused by the heating period, when the cartridge was active, and the cooling period after turning off the cartridge. Furthermore the travel-time changes from all 400 sensorUltrasonic measurement evaluation methods have been proven to be effective for detection of subtle changes, caused by temperature, load or moisture. To detect and localize temperature changes, a concrete block of 4 × 5 × 0.8 m3, including a heating cartridge and multiple temperature sensors, has been set up to change the temperature and monitor the temperature distribution in a certain area inside the specimen. An ultrasonic monitoring system with 40 ultrasonic sensors (20 transmitters, 20 receivers, 25 kHz central frequency) has been implemented on the specimen. Data from 400 sensor combinations was collected over the whole period of the experiment in an interval of 30 minutes. Quantitative methods (CodaWave Interferometry and Time of Flight method) were used to evaluate the changes in ultrasonic travel-time caused by the heating period, when the cartridge was active, and the cooling period after turning off the cartridge. Furthermore the travel-time changes from all 400 sensor combinations were used to locate the heating cartridge.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Sven Grothe
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):The e-journal of nondestructive testing & ultrasonics
Jahr der Erstveröffentlichung:2015
Veröffentlichende Institution:Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:NDT.net
Verlagsort:Kirchwald
Jahrgang/Band:20
Ausgabe/Heft:11
Aufsatznummer:18336
Erste Seite:1
Letzte Seite:4
Veranstaltung:NDT-CE 2015 - International symposium non-destructive testing in civil engineering
Veranstaltungsort:Berlin, Germany
Beginndatum der Veranstaltung:15.09.2015
Enddatum der Veranstaltung:17.09.2015
URN:urn:nbn:de:kobv:b43-346387
URL:http://www.ndt.net/?id=18336
ISSN:1435-4934
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung-Keine Bearbeitung
Datum der Freischaltung:20.02.2016
Referierte Publikation:Nein
Schriftenreihen ohne Nummerierung:Wissenschaftliche Artikel der BAM
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.