• Treffer 6 von 23
Zurück zur Trefferliste

New ignition source 'exploding wire' for the determination of explosion characteristics of combustible dusts in the 20-L-sphere

  • According to international Standards several safety characteristics of dusts are determined in the 20-L-sphere (also known as SIWEK-Chamber). Dust cloud ignition is carried out using pyrotechnical igniters. Due to various disadvantages of pyrotechnical igniters the need for alternative ignition sources arises again and again. An alternative ignition source could be the socalled “exploding wire” or “fuse wire". The paper presents test results of a comparative study between both ignition sources for the determination of the safety characteristics Maximum Explosion Pressure and Maximum Rate of Explosion Pressure Rise of selected dusts in the 20-Lsphere. In addition to that the flame/arc propagation of both ignition sources was analysed by high speed and IR camera recordings. Tests in a windowed autoclave were performed to get information on the influence of turbulence generated due to dispersion of the dust on the shape of the generated flame and its propagation. Turbulence measurementsAccording to international Standards several safety characteristics of dusts are determined in the 20-L-sphere (also known as SIWEK-Chamber). Dust cloud ignition is carried out using pyrotechnical igniters. Due to various disadvantages of pyrotechnical igniters the need for alternative ignition sources arises again and again. An alternative ignition source could be the socalled “exploding wire” or “fuse wire". The paper presents test results of a comparative study between both ignition sources for the determination of the safety characteristics Maximum Explosion Pressure and Maximum Rate of Explosion Pressure Rise of selected dusts in the 20-Lsphere. In addition to that the flame/arc propagation of both ignition sources was analysed by high speed and IR camera recordings. Tests in a windowed autoclave were performed to get information on the influence of turbulence generated due to dispersion of the dust on the shape of the generated flame and its propagation. Turbulence measurements in the windowed autoclave as well as in the 20-L-sphere with a LDA System allowed investigation if the igniter led to turbulence increase at the moment of ignition in comparison to tests without ignition.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • New ignition source 'exploding wire' for the determination of explosion characteristics of combustible dusts in the 20-L-sphere.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Marc Scheid, Alexander Klippel, Rico TschirschwitzORCiD, Volkmar Schröder, Stefan Zirker, Christian Kusche
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):GCPS 2013 - 9th Global congress on process safety (Proceedings)
Jahr der Erstveröffentlichung:2013
Herausgeber (Institution):American Institute of Chemical Engineers
Erste Seite:1
Letzte Seite:10
Freie Schlagwörter:Alternative Zündquelle; Explodierender Draht; Sicherheitstechnische Kenngrößen Staub; Staubexplosionsschutz
Veranstaltung:GCPS 2013 - 9th Global congress on process safety
Veranstaltungsort:San Antonio, TX, USA
Beginndatum der Veranstaltung:28.04.2013
Enddatum der Veranstaltung:02.05.2013
ISBN:978-0-8169-1075-5
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:28.05.2013
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.