Numerical and experimental analysis of reactive fire protection systems applied to solid steel rods in tension

  • The application of intumescent coatings for fire protection of steel constructions is increasing. Thanks to the relative thin thickness of the coatings, the typical visual appearance of the structures can remain essentially unchanged. In Germany, the applicability of the systems is regulated by the national as well as European technical assessments. According to the approvals, the application on steel members in tension is only allowed with limitations. Especially, the application on solid steel rods in tension is currently excluded from the approval. The paper explains the actual state of the art of the application of reactive fire protection systems applied to steel structures. Physical and technical background information are provided. Furthermore, the latest scientific results of an on-going research project funded by the German National Institute of Building Technology (DIBt) and conducted by the Federal Institute for Materials Research and Testing (BAM) will beThe application of intumescent coatings for fire protection of steel constructions is increasing. Thanks to the relative thin thickness of the coatings, the typical visual appearance of the structures can remain essentially unchanged. In Germany, the applicability of the systems is regulated by the national as well as European technical assessments. According to the approvals, the application on steel members in tension is only allowed with limitations. Especially, the application on solid steel rods in tension is currently excluded from the approval. The paper explains the actual state of the art of the application of reactive fire protection systems applied to steel structures. Physical and technical background information are provided. Furthermore, the latest scientific results of an on-going research project funded by the German National Institute of Building Technology (DIBt) and conducted by the Federal Institute for Materials Research and Testing (BAM) will be described.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • JSFE 6-4_5_Numerical and Experimental Analysis of Reactive Fire Protection Systems Applied to Solid Steel Rods in Tension_2015.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Dustin HäßlerORCiD, Sascha HothanORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of Structural Fire Engineering
Jahr der Erstveröffentlichung:2015
Verlag:Multi-Science Publishing
Jahrgang/Band:6
Ausgabe/Heft:4
Erste Seite:275
Letzte Seite:282
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Fire protection; Reactive fire protection system; Steel structure; Tension member
ISSN:2040-2317
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")