Corresponding author der OTH Regensburg
Refine
Year of publication
Document Type
- Article (123)
- conference proceeding (article) (2)
- Part of a Book (1)
- conference talk (1)
- conference proceeding (volume) (1)
- Review (1)
Is part of the Bibliography
- no (129)
Keywords
- Photoacoustic spectroscopy (5)
- Power-to-Gas (5)
- magnetoactive elastomer (5)
- Biomechanik (3)
- Handchirurgie (3)
- Lernprogramm (3)
- magnetoelectric effect (3)
- magnetostriction (3)
- methanation (3)
- piezoelectric polymer (3)
Institute
- Fakultät Maschinenbau (43)
- Fakultät Elektro- und Informationstechnik (37)
- Fakultät Informatik und Mathematik (25)
- Regensburg Center of Biomedical Engineering - RCBE (20)
- Fakultät Angewandte Sozial- und Gesundheitswissenschaften (15)
- Labor Intelligente Materialien und Strukturen (15)
- Regensburg Center of Health Sciences and Technology - RCHST (13)
- Fakultät Angewandte Natur- und Kulturwissenschaften (11)
- Mechatronics Research Unit (MRU) (10)
- Labor Biomechanik (LBM) (9)
- Institut für Sozialforschung und Technikfolgenabschätzung (IST) (8)
- Labor Empirische Sozialforschung (7)
- Regensburg Medical Image Computing (ReMIC) (7)
- Sensorik-Applikationszentrum (SappZ) (7)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (6)
- Labor Werkstoffrandschichtanalytik (5)
- Regensburg Strategic IT Management (ReSITM) (5)
- Technologie-Campus Parsberg-Lupburg (5)
- Fakultät Bauingenieurwesen (4)
- Labor Biofluidmechanik (4)
- Labor Faserverbundtechnik (LFT) (4)
- Labor Sorptionsprozesse (4)
- Labor Biomaterialien (3)
- Labor Medizinprodukte (3)
- Labor für Digitalisierung (LFD) (3)
- Labor für Technikfolgenabschätzung und Angewandte Ethik (LaTe) (3)
- Technologie-Campus Neustadt an der Donau (3)
- Computational Mechanics and Materials Lab (CMM) (2)
- Labor Bauphysik (2)
- Fakultät Architektur (1)
- Fakultät Betriebswirtschaft (1)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (1)
- Labor Datenkommunikation (1)
- Labor Elektrische Maschinen und Antriebstechnik (1)
- Labor Finite-Elemente-Methode (FEM) (1)
- Labor Heizungs- und Klimatechnik (1)
- Labor Laser-Materialbearbeitung (LMP) (1)
- Labor Mikrosensorik (1)
- Labor Optische Übertragungssysteme (1)
- Labor für Baustoffe (1)
Begutachtungsstatus
- peer-reviewed (126)
Optical fiber sensors based on intensity measurement require some form of intensity referencing to avoid errors arising from parasitic losses. Known techniques of referencing such as balanced bridge, divided beam systems or two-wavelength referencing are not suitable for low-cost applications since they use relatively complicated optical components such as multiple LED sources, couplers, filters etc. In this work a novel method of referencing in an extrinsic optical fiber sensor system utilizing temperature dependence of absorption edge in a semiconductor crystal is described. The sensor system comprises a single LED source and no optical fiber junctions. The emission spectrum of an LED depends on its temperature. The reference is provided by controlling the temperature of an LED source and transmission measurements with different emission spectra. The entire process is controlled by a microprocessor unit. Performance of a sensor system is investigated and it is shown that the losses in connectors may be compensated for.
The magnetoelectric response of bi- and symmetric trilayer composite structures to pulsed magnetic fields is experimentally investigated in detail. The structures comprise layers of commercially available piezoelectric (lead zirconate titanate) and magnetostrictive (permendur or nickel) materials. The magnetic-field pulses have the form of a half-wave sine function with duration of 450 µs and amplitudes ranging from 500 Oe to 38 kOe. The time dependence of the resulting voltage is presented and explained by theoretical estimations. Appearance of voltage oscillations with frequencies much larger than the reciprocal pulse length is observed for sufficiently large amplitudes (~1-10 kOe) of the magnetic-field pulse. The origin of these oscillations is the excitation of bending and planar acoustic oscillations in the structures. Dependencies of the magnetoelectric voltage coefficient on the excitation frequency and the applied magnetic field are calculated by digital signal processing and compared with those obtained by the method of harmonic field modulation. The results are of interest for developing magnetoelectric sensors of pulsed magnetic fields as well as for rapid characterization of magnetoelectric composite structures.
The Faculty of Electrical Engineering and Information Technology of the OTH Regensburg developed and implemented a compact freshmen seminar for the afternoon of the first day of study. The intention of this seminar is to help the freshmen during their transition between school and study without losing lecture time in the first semester. The concept was tested with one small study group at the beginning of the summer semester 2015. To rate the impact of the seminar and to find aspects for continuous improvement an evaluation method was developed and used. Due to the good student resonance during the first run, this introduction seminar was held again in the winter semester 2015/16. It is planned to integrate this seminar as a regular session for all freshmen of the faculty curriculum and monitor the long-term effects of student motivation and success.
The dependence of the resonant direct magnetoelectric effect on temperature is studied experimentally in planar composite structures. Samples of rectangular shapes with dimensions of 5 mm x 20 mm employed ferromagnetic layers of either an amorphous (metallic glass) alloy or nickel with a thickness of 20-200 m and piezoelectric layers of single crystalline langatate material or lead zirconate titanate piezoelectric ceramics with a thickness of 500 m. The temperature of the samples was varied in a range between 120 and 390 K by blowing a gaseous nitrogen stream around them. It is shown that the effective characteristics of the magnetoelectric effectsuch as the mechanical resonance frequency f(r), the quality factor Q and the magnitude of the magnetoelectric coefficient (E) at the resonance frequencyare contingent on temperature. The interrelations between the temperature changes of the characteristics of the magnetoelectric effect and the temperature variations of the following material parametersYoung's modulus Y, the acoustic quality factor of individual layers, the dielectric constant epsilon, the piezoelectric modulus d of the piezoelectric layer as well as the piezomagnetic coefficients ((n)) of the ferromagnetic layerare established. The effect of temperature on the characteristics of the nonlinear magnetoelectric effect is observed for the first time. The results can be useful for designing magnetoelectric heterostructures with specified temperature characteristics, in particular, for the development of thermally stabilized magnetoelectric devices.
Wireless sensor networks usually rely on internal permanent or rechargeable batteries as a power supply, causing high maintenance efforts. An alternative solution is to supply the entire system by harvesting the ambient energy, for example, by transducing ambient vibrations into electric energy by virtue of the piezoelectric effect. The purpose of this paper is to present a simple engineering approach for the bandwidth optimization of vibration energy harvesting systems comprising multiple piezoelectric cantilevers (PECs). The frequency tuning of a particular cantilever is achieved by changing the tip mass. It is shown that the bandwidth enhancement by mass tuning is limited and requires several PECs with close resonance frequencies. At a fixed frequency detuning between subsequent PECs, the achievable bandwidth shows a saturation behavior as a function of the number of cantilevers used. Since the resonance frequency of each PEC is different, the output voltages at a particular excitation frequency have different amplitudes and phases. A simple power-transfer circuit where several PECs with an individual full wave bridge rectifier are connected in parallel allows one to extract the electrical power close to the theoretical maximum excluding the diode losses. The experiments performed on two- and three-PEC arrays show reasonable agreement with simulations and demonstrate that this power-transfer circuit additionally influences the frequency dependence of the harvested electrical power.
Natural and technological hazards have a major impact on environmental and human safety. Risk assessment plays an essential role in the risk management of the effects of such hazards. This contribution summarizes first the general formulation of risk depending on two parameters: hazard probability and associated consequences. Problems faced in industrial applications based on the experience of the author are discussed. Risk acceptance criteria for the contributors to risk i.e. human, economic and environment are critically reviewed. Resilience based criteria are also included and conclusions for future developments are provided.
Introduction: Improving energy efficiency and reducing energy wastage is an important topic of our time. But it is quite difficult to figure out how much of our total electricity bill can be mapped to which device or at what time the device used it. We believe energy efficiency of normal households can be improved, if this kind of transparency would be available. In this article, we present a system for energy measurement at mains sockets to gain a transparent view of energy consumption for each device in a household. It consists of several smart energy measuring devices (SEMDs) that use a low-power radio protocol to dynamically build and connect to a radio network to transfer power usage date to a server. At the server, the data is stored and can be accessed via web interface.
Results: Our primary goal was to build a back-end system for an energy metering platform with very low energy consumption. This platform can provide data for a variety of services that enables users (the consumers) to understand and improve their energy consumption behavior and increase overall energy efficiency of their households.
It is shown that the critical exponent for the effective shear modulus of a composite medium where a compliant polymer matrix is filled with ferromagnetic particles may significantly depend on the external magnetic field. The physical consequence of this dependence is the critical behavior of the relative magnetorheological effect.
Moving forward together
(2018)
In this paper, we consider the reconstruction problem of photoacoustic tomography (PAT) with a flat observation surface. We develop a direct reconstruction method that employs regularization with wavelet sparsity constraints. To that end, we derive a wavelet-vaguelette decomposition (WVD) for the PAT forward operator and a corresponding explicit reconstruction formula in the case of exact data. In the case of noisy data, we combine the WVD reconstruction formula with soft-thresholding, which yields a spatially adaptive estimation method. We demonstrate that our method is statistically optimal for white random noise if the unknown function is assumed to lie in any Besov-ball. We present generalizations of this approach and, in particular, we discuss the combination of PAT-vaguelette soft-thresholding with a total variation (TV) prior. We also provide an efficient implementation of the PAT-vaguelette transform that leads to fast image reconstruction algorithms supported by numerical results.
Purpose
Age-related macular degeneration (AMD) is a common threat to vision. While classification of disease stages is critical to understanding disease risk and progression, several systems based on color fundus photographs are known. Most of these require in-depth and time-consuming analysis of fundus images. Herein, we present an automated computer-based classification algorithm.
Design Algorithm development for AMD classification based on a large collection of color fundus images. Validation is performed on a cross-sectional, population-based study.
Participants.
We included 120 656 manually graded color fundus images from 3654 Age-Related Eye Disease Study (AREDS) participants. AREDS participants were >55 years of age, and non-AMD sight-threatening diseases were excluded at recruitment. In addition, performance of our algorithm was evaluated in 5555 fundus images from the population-based Kooperative Gesundheitsforschung in der Region Augsburg (KORA; Cooperative Health Research in the Region of Augsburg) study.
Methods.
We defined 13 classes (9 AREDS steps, 3 late AMD stages, and 1 for ungradable images) and trained several convolution deep learning architectures. An ensemble of network architectures improved prediction accuracy. An independent dataset was used to evaluate the performance of our algorithm in a population-based study.
Main Outcome Measures.
κ Statistics and accuracy to evaluate the concordance between predicted and expert human grader classification.
Results.
A network ensemble of 6 different neural net architectures predicted the 13 classes in the AREDS test set with a quadratic weighted κ of 92% (95% confidence interval, 89%–92%) and an overall accuracy of 63.3%. In the independent KORA dataset, images wrongly classified as AMD were mainly the result of a macular reflex observed in young individuals. By restricting the KORA analysis to individuals >55 years of age and prior exclusion of other retinopathies, the weighted and unweighted κ increased to 50% and 63%, respectively. Importantly, the algorithm detected 84.2% of all fundus images with definite signs of early or late AMD. Overall, 94.3% of healthy fundus images were classified correctly.
Conclusions
Our deep learning algoritm revealed a weighted κ outperforming human graders in the AREDS study and is suitable to classify AMD fundus images in other datasets using individuals >55 years of age.
Objective:
Magneto-active Polymers (MAP) are smart materials whose mechanical characteristics, such as elastic and shear moduli, may be controllable by means of an externally applied magnetic field.
Methods:
Various additives may be used to influence the characteristics of the polymer matrix whilst a suspension of soft and/or hard magnetic particles determine the magnetic properties of the composite. Both pre-cure and post-cure magnetization is possible.
Results:
A range of control strategies have been investigated for evaluation of the system using fluids of differing kinematic viscosity.
Conclusion:
Depending on the degree of magnetic field homogeneity, magneto-deformation and magnetostriction contribute to MAP actuation. This paper presents a novel application in the form of a peristaltic MAP tube system, applicable to flow control and pumping of hemorheological fluids in blood circulatory systems for biomedical research purposes.
Smart Stiction
(2019)
Soft robotics could loosely be described as the engineering science of expanded dexterity through controllable flexibility. The exploitation of controllable compliance through the judicious choice of soft flexible members, as opposed to a finite number of rigid kinematic joints, can result in greater dexterity without compromising simplicity. One example is the replacement of segmented mechanical legs with simple compliant material eruciform prolegs. To achieve this in robotics, without introducing additional mechanical joints, mobile surfaces with switchable coefficients of friction is essential. This paper explains how, using silicone based smart materials, the rapid alternation between kinematic and static friction (stiction) may be achieved.
This paper concerns recent research into the autonomous formation of micro-structures in low carbonyl iron powder (CIP) concentration magneto active polymers (MAP). Higher concentrations of CIP show an isotropic distribution of magnetic filler throughout the entire sample, while autonomous structure formation is possible at mass concentrations lower than 3%. The formation of micro-toroids commences as CIP concentration approaches 1% wt. Further development of coherent rings with a defined order follow as CIP concentrations increase toward 2% wt, whilst exceeding 3% wt leads to the same isotropic distribution found in higher concentration MAP. Structured samples containing between 1% wt and 3% wt CIP were investigated using X-Ray tomography where solitary structures could clearly be observed. The ring structures represent microinductivities whose geometries can be manipulated during fabrication. In addition, these structures are magnetic field sensitive. This is not only relevant to applications in the GHz and THz areas but recent research has revealed implications for optical, thermal, acoustic and even chemical MAP sensors. (C) 2019 Author(s).
The direct magnetoelectric (ME) effect is investigated in a planar structure comprising mechanically coupled layers of a magnetostrictive fibrous composite (MFC) and a piezoelectric ceramics (lead zirconate titanate, PZT). The MFC is an array of Ni-wires with a diameter of 200 mu m that are aligned parallel to each other in a single layer. The wires are separated by a distance of 250 or 500 mu m and fixed in a polyamide matrix. The structure was placed in a tangential constant field H and was excited by an alternating magnetic field h parallel to H, while the voltage generated by the PZT layer was measured. The resulting field dependences of the magnetization M(H) and the magnetostriction lambda(H) were determined by the orientation of the field H in the plane of the structure and the distance between the Ni-wires. The ME coupling coefficient of the structure decreased from 4.8 to 0.25 V/A when the orientation of H was changed from parallel to perpendicular to Ni-wires. With an increase in the excitation field amplitude h, a nonlinear ME effect in the output voltage, namely frequency doubling, was observed. The frequency and field dependences of the efficiency of the ME transduction in the MFC-piezoelectric heterostructure are well described by the existing theory.
This work describes the development of a new miniature extruder, essential to cavity-free 3D printing of silicone-based smart materials. This makes the 3D printing of magnetoactive and electroactive polymer soft robotic components and devices directly from CAD data possible. The special feature of such an extruder is that it is designed for use with addition-crosslinking RTV-2 silicones, including solid particulate additives. The extruder merges the respective components automatically during extrusion which obviates the need for premixing and vacuum evacuation. Problems associated with inhomogeneities and unwanted cavity production are consequently eliminated. Rheological details necessary to the design, together with some preliminary performance results, are presented.
This field report presents and discusses methodological issues and challenges encountered in a mixed-methods research project on asylum seekers in Bavaria, Germany. It documents the research design of, and field experiences in, a quantitative survey based on a quota sampling procedure and a qualitative study, both of which were conducted in collective accommodation for asylum seekers at selected locations in that federal state. Standardized PAPI multiple-topic questionnaires were completed by asylum seekers from Syria, Afghanistan, Eritrea, and Iraq (N = 779); most of the questionnaires were self-administered. In addition, 12 qualitative face-to-face biographical interviews were conducted in order to gain an in-depth understanding of attitudes and experiences of asylum seekers. This report focuses on the following aspects: the use of gatekeepers to facilitate participant recruitment; sampling procedures; the involvement of interpreters in the data collection process; response bias and response behaviors among asylum seekers; and the experiences gained from data collection in collective accommodation for asylum seekers.
Power-to-Methane as one part of Power-to-Gas has been recognized globally as one of the key elements for the transition towards a sustainable energy system. While plants that produce methane catalytically have been in operation for a long time, biological methanation has just reached industrial pilot scale and near-term commercial application. The growing importance of the biological method is reflected by an increasing number of scientific articles describing novel approaches to improve this technology. However, these studies are difficult to compare because they lack a coherent nomenclature. In this article, we present a comprehensive set of parameters allowing the characterization and comparison of various biological methanation processes. To identify relevant parameters needed for a proper description of this technology, we summarized existing literature and defined system boundaries for Power-to-Methane process steps. On this basis, we derive system parameters providing information on the methanation system, its performance, the biology and cost aspects. As a result, three different standards are provided as a blueprint matrix for use in academia and industry applicable to both, biological and catalytic methanation. Hence, this review attempts to set the standards for a comprehensive description of biological and chemical methanation processes.
We investigated magnetic-field-induced modifications of the surface roughness of magnetoactive elastomers (MAEs) with four material compositions incorporating two concentrations of ferromagnetic microparticles (70 wt% and 80 wt%) and exhibiting two shear storage moduli of the resulting composite material (about 10 kPa and 30 kPa). The analysis was primarily based on spread optical reflection measurements. The surfaces of all four materials were found to be very smooth in the absence of magnetic field (RMS roughness below 50 nm). A maximal field-induced roughness modification (approximately 1 m/T) was observed for the softer material with the lower filler concentration, and a minimal modification (less than 50 nm/T) was observed for the harder material with the higher filler concentration. All four materials showed a significant decrease in the total optical reflectivity with an increasing magnetic field as well. This effect is attributed to the existence of a distinct surface layer that is depleted of microparticles in the absence of a magnetic field but becomes filled with particles in the presence of the field. We analyzed the temporal response of the reflective properties to the switching on and off of the magnetic field and found switching-on response times of around 0.1 s and switching-off response times in the range of 0.3-0.6 s. These observations provide new insight into the magnetic-field-induced surface restructuring of MAEs and may be useful for the development of magnetically reconfigurable elastomeric optical surfaces.
This review gives a worldwide overview on Power-to-Gas projects producing hydrogen or renewable substitute natural gas focusing projects in central Europe. It deepens and completes the content of previous reviews by including hitherto unreviewed projects and by combining project names with details such as plant location. It is based on data from 153 completed, recent and planned projects since 1988 which were evaluated with regards to plant allocation, installed power development, plant size, shares and amounts of hydrogen or substitute natural gas producing examinations and product utilization phases. Cost development for electrolysis and carbon dioxide methanation was analyzed and a projection until 2030 is given with an outlook to 2050. The results show substantial cost reductions for electrolysis as well as for methanation during the recent years and a further price decline to less than 500 euro per kilowatt electric power input for both technologies until 2050 is estimated if cost projection follows the current trend. Most of the projects examined are located in Germany, Denmark, the United States of America and Canada. Following an exponential global trend to increase installed power, today's Power-to-Gas applications are operated at about 39 megawatt. Hydrogen and substitute natural gas were investigated on equal terms concerning the number of projects.