Anatomical differences between individuals are often neglected in musculoskeletal models, but they are necessary in case of subject-specific questions regarding the lumbar spine. A modification of models to each subject is complex and the effects on lumbar loading are difficult to assess. The objective of this thesis is to create a validated musculoskeletal model of the human body, which facilitates a subject-specific modification of the geometry of the lumbar spine. Furthermore, important parameters are identified in sensitivity studies and a case study regarding multifidus muscle atrophy after a disc herniation is conducted. Therefore, a generic model is heavily modified and a semi-automatic process is implemented. This procedure remodels the geometry of the lumbar spine to a subject-specific one on basis of segmented medical images. The resulting five models are validated with regard to the lumbar loading at the L4/L5 level. The influence of lumbar ligament stiffness is determined by changing the stiffness values of all lumbar ligaments in eleven steps during a flexion motion. Sensitivities of lumbar loading to an altered geometry of the lumbar spine are identified by varying ten lumbar parameters in simulations with each model in four postures. The case study includes an analysis of the loading of the multifidus muscle and of the lumbar discs throughout various stages of disc herniation. This time each model performs four motions with two different motion rhythms. The results indicate that lumbar motion and loading is dependent on lumbar ligament stiffness. Furthermore, subject-specific modelling of the lumbar spine should include at least the vertebral height, disc height and lumbar lordosis. The results of the case study suggest that an overloading of the multifidus muscle could follow disc herniation. Additionally, a subsequent atrophy of the muscles could expose adjacent levels to an increased loading, but these findings are highly dependent on the individual.
Musculoskeletal simulations of lumbar spine loading rely on a geometrical representation of the anatomy. However, this data has an inherent inaccuracy. This study evaluates the influence of defined geometrical parameters on lumbar spine loading utilising five parametrised musculoskeletal lumbar spine models for four different postures. The influence of the dimensions of vertebral body, disc, posterior parts of the vertebrae as well as the curvature of the lumbar spine was studied. Additionally, simulations with combinations of selected parameters were conducted. Changes in L4/L5 resultant joint force were used as outcome variable. Variations of the vertebral body height, disc height, transverse process width and the curvature of the lumbar spine were the most influential.
These parameters can be easily acquired from X-rays and should be used to morph a musculoskeletal lumbar spine model for subject-specific approaches with respect to bone geometry. Furthermore, the model was very sensitive to uncommon configurations and therefore, it is advised that stiffness properties of discs and ligaments should be individualised.
This article presents first results of artificial aging experi-ments by ultraviolet (UV) irradiation on thermoplasticmaterials conducted as an intent of the research project Thermoplastic Composite Structures (TheCoS) in colla-boration of the Ostbayerische Technische Hochschule(OTH) Regensburg and the University of West Bohemia(UWB) in Pilsen as part of a cross-border cooperation. In technical applications, thermoplastic materials are oftenaffected by aging and a related deterioration of the mechanical properties. Therefore, it is necessary to identifythe aging behavior of thermoplastic materials. For this,experiments were performed for three thermoplasticmaterials, namely polypropylene (PP), ultra high mole -cular weight polyethylene (UHMWPE) and high impactstrength polystyrene (HIPS). For these experiments, a UV chamber was constructed according to the internationalstandard EN ISO 4892-3 for simulation of exposurebehind window glass. The results are evaluated by testing the flexural strength and the dynamic mechanicalresponse after a selected period of time under UV lightand then compared to untreated test specimens.