Energie und Mobilität
Refine
Year of publication
Document Type
- conference proceeding (article) (168)
- Article (143)
- Part of a Book (41)
- conference talk (32)
- Report (19)
- conference proceeding (presentation, abstract) (8)
- Book (7)
- Master's Thesis (4)
- Preprint (4)
- Part of Periodical (3)
- Edited collection (1)
- Review (1)
Is part of the Bibliography
- no (431)
Keywords
- Energiewende (27)
- Erneuerbare Energien (27)
- Klimaneutralität (22)
- Power-to-Gas (21)
- Sektorenkopplung (16)
- Energiespeicher (14)
- Power-to-X (9)
- Wasserstoff (8)
- Netzplanung (7)
- Blindleistung (6)
Institute
- Fakultät Elektro- und Informationstechnik (240)
- Fakultät Maschinenbau (155)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energiespeicher (76)
- Combustion Engines and Emissions Control Laboratory (CEEC) (40)
- Forschungsstelle für Energienetze und Energiespeicher (FENES) / Forschungsgruppe Energienetze (38)
- Labor Elektrische Maschinen und Antriebstechnik (37)
- Computational Mechanics and Materials Lab (CMM) (20)
- Technologie-Campus Neustadt an der Donau (20)
- Labor Intelligente Materialien und Strukturen (17)
- Fakultät Informatik und Mathematik (15)
Begutachtungsstatus
- peer-reviewed (187)
- begutachtet (15)
This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m−2∙K−1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake.
Dieser Bericht entstand auf Initiative der Studierenden des Masterstudiengangs „Elektro- und Informationstechnik (MEI)“, die an der Pflichtlehrveranstaltung „Forschungsmethoden und Seminar (FMS)“ im Wintersemester 2022/23 teilnahmen.
Diese Lehrveranstaltung hat das Ziel, systematisch an das wissenschaftliche Arbeiten, speziell die Wissenschaftskommunikation, heranzuführen.
Daher war geeignete Literatur zu einem individuellen Thema zu recherchieren, Veröffentlichungen auf ihre Relevanz hin zu beurteilen und letztendlich eine eigene Ausarbeitung basierend auf der Literaturrecherche zu erarbeiten und diese in einem Vortrag zu präsentieren.
Parallel dazu erfolgte im Theorieteil die entsprechende Hinführung zu den
verschiedenen Elementen der Wissenschaftskommunikation:
• Bedeutung der Wissenschaftskommunikation für die Arbeit der Ingenieure
in Forschung und Entwicklung
• Literaturrecherche, Suchmaschinen, Sichtung und Analyse vorhandener
Publikationen, Bewertung der Qualität aufgefundener Fachliteratur,
Auswahl geeigneter Materialien für die eigene Arbeit
• Aufbereitung und Darstellung der recherchierten technischer Inhalte
in Form einer seitenanzahlbegrenzten wissenschaftlichen Ausarbeitung
• Einhalten formaler Randbedingungen bzgl. Strukturierung, einschl.
Bildnachweise und Zitationsstile
• Peer-review-Prozess bei wertschätzender Beurteilung der Leistung
anderer
• Publikumsangepasstes Aufbereiten komplexer fachlicher Inhalte mit
hochschulöffentlicher Präsentation der Ergebnisse
• Führen mündlicher wissenschaftlicher Diskurse Nachdem die Masterstudierenden in der Regel über noch keine eigene wissenschaftliche Forschungserfahrung bzw. -inhalte verfügen, lag der
wählbare Schwerpunkt der Literatursuche auf der Bearbeitung von vorgegeben aktuellen technischen oder gesellschaftspolitischen Forschungsthemen.
Die Bundesregierung hat ambitionierte Ausbaupfade für die Windenergie und Photovoltaik festgelegt. Allerdings gefährdet vor allem der Verteilnetzausbau und der Netzanschluss der Erneuerbare-Energien-Anlagen (EE-Anlagen) die Erreichung dieser hochgesteckten Ziele. In einem Gutachten im Auftrag der Fraktion von Bündnis 90/DIE GRÜNEN im Bayerischen Landtag identifiziert Prof. Dr.-Ing. Oliver Brückl die wesentlichen Hemmnisse für den beschleunigten Verteilnetzausbau und den Netzanschluss für EE-Anlagen und diskutiert Lösungsansätze in folgenden Bereichen:
Regulierungsrahmen für die Verteilnetzbetreiber, Genehmigungsverfahren von Netzausbauprojekten, Praxis der Netzintegration von EE-An lagen, Personalkapazitäten, Beschaffung von Betriebsmitteln und Bau von Anlagen, Zertifizierungsprozess für den Netzanschluss von EE-Anlagen.
Im Rahmen des Gutachtens wurden ca. 35 Interviews mit verschiedenen Stakeholdern geführt: Netzbetreiber und Stadtwerke, Projektierer*innen, Herstellerindustrie, Verbände und Behörden.
This paper presents a method for integrating industrial consumers owning compensation systems as alternative reactive power sources into grid operating processes. In remuneration, they receive a market-based provision of reactive power. The aim is to analyze the potential of reactive power compensation systems of industrial companies connected to medium-voltage (10 kV–30 kV) AC grids in order to increase the reactive power ability of distribution grids. Measurement methods and reactive power potential results of six industrial companies are presented to characterize the amount and temporal availability of their reactive power potential. The presented approach for using the decentralized reactive power potential is a centralized reactive power control method and is based on optimal power flow (OPF) calculations. An optimization algorithm based on linear programming is used to coordinate a reactive power retrieval tuned to the actual demand. The influencing quantities are the current grid status (voltage and load flow capacity reserves at grid nodes and power lines) and the current reactive power potential of the reactive power sources. The compensation impact of six measured industrial companies on an exemplary medium-voltage grid is shown by an application example.
Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht.
Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten.
Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb.
Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz.
Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.
The currently still high fossil energy demand is forcing the glass industry to search for innovative approaches for the reduction in CO2 emissions and the integration of renewable energy sources. In this paper, a novel power-to-methane concept is presented and discussed for this purpose. A special focus is on methods for the required CO2 capture from typical flue gases in the glass industry, which have hardly been explored to date. To close this research gap, process simulation models are developed to investigate post-combustion CO2 capture by absorption processes, followed by a techno-economic evaluation. Due to reduced flue gas volume, the designed CO2 capture plant is found to be much smaller (40 m3 absorber column volume) than absorption-based CO2 separation processes for power plants (12,560 m3 absorber column volume). As there are many options for waste heat utilization in the glass industry, the waste heat required for CO2 desorption can be generated in a particularly efficient and cost-effective way. The resulting CO2 separation costs range between 41 and 42 EUR/t CO2, depending on waste heat utilization for desorption. These costs are below the values of 50–65 EUR/t CO2 for comparable industrial applications. Despite these promising economic results, there are still some technical restrictions in terms of solvent degradation due to the high oxygen content in flue gas compositions. The results of this study point towards parametric studies for approaching these issues, such as the use of secondary and tertiary amines as solvents, or the optimization of operating conditions such as stripper pressure for further cost reductions potential.
Mit der Energiewende geht eine starke Dezentralisierung der Energieeinspeisung einher. So sind im Deutschland des Jahres 2020 rund 31.000 Windenergieanlagen (WEA) in Betrieb, während bei der Solarenergie vor kurzem die zweimillionste Photovoltaik-Anlage (PVA) installiert wurde. Fast alle diese dezentralen Energieressourcen (DER) sind nach den Einspeiserichtlinien der Vergangenheit und der Gegenwart in der Lage, Blindleistung bereitzustellen, um die Spannung im Netz zu regeln und zum Blindleistungsausgleich beizutragen. Weitere potentielle dezentrale Blindleistungsquellen wie Blockheizkraftwerke, Kompensationsanlagen und perspektivisch sogar Verbraucher und Speicher sind im Verteilnetz zu finden. Durch den stetigen Rückbau konventioneller Großkraftwerke, welche dem Übertragungsnetz bisher als Blindleistungsquellen zur Verfügung standen, bedarf es einer Untersuchung mit der Fragestellung, in welchem Maß die neue Erzeugungslandschaft auch in diesem Feld als Ersatz dienen kann. Ein mögliches Hindernis für einen breitangelegten Einsatz von DER zu Zwecken des spannungsebenenübergreifenden Blindleistungsmanagements ist mangelndes Wissen über die Regeldynamik dieser verteilten Blindleistungsquellen. Übertragungs- und Verteilnetzbetreiber, die DER aktiv für Blindleistungsausgleich oder statische Spannungsregelung einsetzen, geben in der Regel ihre Blindleistungsanforderungen in kleineren Stufen mit erheblichen Latenzzeiten zwischen zwei Schritten weiter. Befürchtet wird, dass schnellere Sprünge in der Blindleistungsvorgabe zu instabilen Betriebszuständen oder anderweitigen Fehlfunktionen im Netz führen können. Eine genauere Kenntnis der dynamischen Fähigkeiten vorhandener Blindleistungsquellen sowie der Auswirkungen auf die Netzstabilität und den Netzschutz könnte dazu beitragen, die Geschwindigkeit der Blindleistungsbereitstellung zu optimieren und somit temporäre Spannungsschwankungen und -verluste zu minimieren und die Spannungsstabilität insgesamt zu verbessern. Durch eine entsprechende Regelungs- und Einsatzstrategie kann ein optimales Zusammenspiel der verschiedenen Technologien zur Deckung der Blindleistungsbedarfe für unterschiedliche Zeitbereiche erzielt werden. Hierfür ist eine genaue Kenntnis der Blindleistungsstellgeschwindigkeiten und des dynamischen Regelverhaltens erforderlich. Dieser Beitrag stellt dazu Ergebnisse aus dem Forschungsprojekt „Q-Integral“ vor. Um die relevanten Zeitkonstanten der Blindleistungsbereitstellung vollständig aufzuführen, werden zunächst typische Kommunikationszeiten für die Übermittlung von Sollwerten diskutiert. Anschließend werden Untersuchungen zu theoretischen und praktischen Reaktionszeiten verschiedener Blindleistungsquellen vorgestellt. Dafür werden verschiedene Technologien wie Umrichter für PVA, Batteriespeicher und WEA sowie Synchrongeneratoren, die bei thermischen Kraftwerken die dominierende Technologie sind, betrachtet. Abschließend werden diese Werte mit realen Blindleistungsstellgeschwindigkeiten von ausgedehnten Wind- und Solarkraftwerken verglichen.
Im Zuge der Energiewende ergibt sich ein Wandel in der Struktur des Elektrizitätsversorgungsnetzes. Die Verschiebung der Erzeugungsleistung von konventionellen Großkraftwerken in höheren Netzebenen hin zu dezentralen erneuerbaren Energieanlagen in niedrigeren Netzebenen resultiert sowohl in bidirektionalen Lastflüssen als auch in schwankenden Einspeisecharakteristiken. Des Weiteren folgen durch den Wegfall von Großkraftwerken als Blindleistungsquellen Leistungsdefizite in der Übertragungsnetzebene, die kompensiert werden müssen. Daraus resultieren Herausforderungen an einen sicheren und zuverlässigen Betrieb der Verteil- und Übertragungsnetze. Neue Konzepte müssen für die Erbringung von Blindleistung entwickelt werden, es soll mehr Blindleistung aus dem Verteilungsnetz zur Verfügung gestellt werden, um die Systemstabilität zu wahren. Im Rahmen des Projektes Q-Integral wird das Thema „Blindleistung“ (Q) ganzheitlich untersucht. Es werden dazu verschiedene Erbringungsoptionen für Blindleistung hinsichtlich technischer und wirtschaftlicher Potentiale untersucht, die in ein funktionales und effizientes Blindleistungsmanagement eingebracht werden. Die Untersuchungsansätze dafür sind sowohl spannungsebenen-übergreifend als auch netzbetreiber-übergreifend. Ein Ansatzpunkt des Projektes ist die Betrachtung der Blindleistungsbereitstellung von Industriebetrieben. Dazu wird das Potential von Betrieben, die an das Verteilnetz angeschlossen sind und Blindleistung durch Kompensations- oder Erzeugungsanlagen bereitstellen können, untersucht. Ziel ist es, das gesicherte und maximale induktive sowie kapazitive Potential zu bestimmen. Das gesicherte kapazitive Potential kann genutzt werden, um Aussagen darüber zu treffen, wie stark dem Spannungsfall im vorgelagerten Netz zu Starklastzeiten entgegengewirkt werden kann. Anhand des gesicherten induktiven Potentials kann ein Spannungsanstieg während Schwachlastzeiten ausgeglichen werden kann. In diesem Beitrag werden Ergebnisse aus dem Projekt Q-Integral vorgestellt. Dazu werden zuerst die Berechnungsgrundlagen der induktiven und kapazitiven Blindleistungspotentiale aufgezeigt und die Ergebnisse der Berechnungen vorgestellt. Die gewonnen Ergebnisse entstammen aus Messungen an einem Industriebetrieb mit Blindleistungskompensationsanlagen (BKA), den entsprechenden Reglern der Anlagen und einer installierten Kompensationsleistung von 1600 kvar. Sowohl die Lastgänge als auch das Schaltverhalten der einzelnen Kompensationsanlagen liegen den Berechnungen zugrunde. Um den Austausch der Blindleistung an der Übergabestelle des Betriebs zum Mittelspannungsnetz netzdienlich einzustellen, bedarf es eines geeigneten Regelkonzepts, das neben den BKAs auch weitere Q-Quellen berücksichtigt. Deshalb wird abschließend ein Regelkonzept vorgestellt, das den technisch-optimierten Blindleistungsabruf unter Berücksichtigung mehrerer Blindleistungsquellen behandelt.
The initiated energy transition leads to extensive changes in the supply of energy. The increasing use of renewable energy causes a shift of the produced power from centralized conventional power plants to decentralized energy plants. Because of this redistribution and the related change of load-flows, new challenges and problems for distribution system operators appear. This includes the integration of new loads and plants into the existing power grid and the guarantee of a high supply security and quality. It also includes strengthened requirements for the use and provision of reactive power. The project “SyNErgie” (“Systemoptimierendes Netz- und Energiemanagement für Verteilungsnetze der Zukunft“) deals with the development of a new reactive power management, which gets embedded in grid planning and controlling processes. One focus of the project is on the integration of decentralized energy plants (DEPs) to the reactive power management. The aim is to develop a decentralized and self-sufficient reactive power control system, which only works with local available information (measures). Therefore is no necessity of a complex communication system to the grid control center. Self-controlled Q-controller in the DEPs get characteristic curves and control the reactive power sources with local measurements (e.g. current, voltage, effective power). This new reactive power control management aims for the reactive power compensation in order to increase the integration capacity of loads and plants in a grid [2]. In order to generate characteristic curves for DEPs, it is necessary to analyze the correlation behavior between the local available measurements at the DEPs and the overall-Q-behavior of the grid group at the transformer. In that regard, influencing quantities should be considered. The aim is to involve und evaluate all relevant influencing quantities in order to determine energy plants and certain operating points, in which the correlation behavior and the prediction for the overall-Q-behavior are sufficient. The next step is to develop a model that fits these correlation behaviors and generate characteristic curves. One method to generate characteristic curves for the Q-controllers is regression analysis. The developed Q-control-system with the characteristic curves will be tested, evaluated and optimized in a following field test in cooperation with distribution system operators.
Um einen sicheren und zuverlässigen Stromnetzbetrieb zu gewährleisten, muss die Spannung im Grundfall als auch bei ungeplanten Ausfällen in definierten Bereichen gehalten werden. Im Übertragungsnetz wird hierfür bisher Blindleistung hauptsächlich aus Blindleistungskompensationsanlagen und konventionellen Großkraftwerken eingesetzt. Zukünftig wird nach §12h EnWG eine marktgestützte Beschaffung dieser Dienstleistung zur Spannungsregelung vorgeschrieben. Zugleich verändert sich der Blindleistungsbedarf der Netzbetriebsmittel durch die Integration erneuerbarer Energieanlagen und der Elektromobilität sowie durch den Netzausbau bei Übertragungs- und Verteilungsnetzbetreibern. Es bedarf somit angepasster Netzbetriebs- und Netzplanungskonzepte für ein technisch effizientes und wirtschaftlich günstiges Blindleistungsmanagement. Dieser Beitrag beschäftigt sich damit, Prozessansätze und Methodiken für ebendieses in der Netzplanung aufzuzeigen, um erforderliche Blindleistungskapazitäten unter minimalen Gesamtkostenaufwand und unter Berücksichtigung einer effizienten Blindleistungsbedarfsdeckung zu bestimmen. Dabei liegt der Fokus verstärkt in der Bedarfsanalyse.
Since conventional generation plants provide a considerable share of reactive power but are gradually being shut down due to energy transition, leading to power deficits at the transmission grid level, new concepts for the supply of reactive power must be developed. As one possibility for the latter, industrial plants in the distribution grid are considered suitable, as their reactive power potentials can contribute to voltage maintenance and thus to a grid- or system-serving behavior. In this paper, the determination of reactive power potentials provided by industrial compensation systems (ICS) is presented. An industrial plant in the medium voltage grid, with three installed ICSs, is investigated. The potentials are determined and described based on their time characteristics, which provide information about the occurrence and distribution of inductive and capacitive potentials. A grid simulation of the investigated industrial grid is used to analyze the effects of retrieving the reactive power potentials regarding equipment utilizations and voltage limits.
The provision of reactive power is one option for maintaining the grid voltage, that is defined as an ancillary service in Germany. This paper presents an approach for determining deficient voltage deviation demands within an electrical grid for long term reactive power planning investigations. In contrast to previous approaches, which evaluate the Q-behavior of extended ward elements or grid assets, voltage deviations are analyzed bus-specifically. So further reactive power planning investigations are able to scale and optimize additional reactive power sources directly on planning voltage limits using load flow sensitivity techniques. The focus lies on the analysis of the steady state demand at base case conditions. Therefore, a grid planning process is conceptualized. An optimal power flow algorithm based on Differential Evolution is used for an optimal reactive power dispatch of installed reactive power sources, e. g. reactive power compensation systems or (renewable) energy sources to minimize the total voltage deviation according to voltage limits of Transmission System Operators planning principles. Methodological and processuals specifications as well as an application use case with an exemplary transmission system are presented in this paper.
This work aims at investigating the kinetic mechanisms of the reduction/oxidation (redox) reactions of iron oxide/iron pellets under different operating conditions. The reaction principle is the basis of a thermochemical hydrogen storage system. To simulate the charging phase, a single pellet consisting of iron oxide (90% Fe2O3, 10% stabilising cement) is reduced with different hydrogen (H2) concentrations at temperatures between 600 and 800 °C. The discharge phase is initiated by the oxidation of the previously reduced pellet by water vapour (H2O) at different concentrations in the same temperature range. In both reactions, nitrogen (N2) is used as a carrier gas. The redox reactions have been experimentally measured in a thermogravimetric analyser (TGA) at a flow rate of 250 mL/min. An extensive literature review has been conducted on the existing reactions’ kinetic mechanisms along with their applicability to describe the obtained results. It turned out that the measured kinetic results can be excellently described with the so-called shrinking core model. Using the geometrical contracting sphere reaction mechanism model, the concentration- and temperature-dependent reduction and oxidation rates can be reproduced with a maximum deviation of less than 5%. In contrast to the reduction process, the temperature has a smaller effect on the oxidation reaction kinetics, which is attributed to 71% less activation energy (Ea,Re=56.9 kJ/mol versus Ea,Ox=16.0 kJ/mol). The concentration of the reacting gas showed, however, an opposite trend: namely, to have an almost twofold impact on the oxidation reaction rate constant compared to the reduction rate constant.
Im Projekt MAGGIE wurden für das genossenschaftliche historische Stadtquartier „Margaretenau“ in Regensburg Musterlösungen für energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht.
Dazu wurde ein bestehendes Wohngebäude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus Wärmepumpentechnologie und Kraft- Wärme-Kopplung ausgestattet und untersucht, ergänzt durch eine dynamische Wärmelogistik zur Verringerung von Verteilungsverlusten.
Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems während des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Strombörse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltwärme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Gebäudebetrieb.
Für die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realität getestet. Am Bestandsgebäude kam anstelle eines Wärmedämmverbundsystems ein innovativer Dämmputz mit Mikrohohlglaskugeln zum Einsatz.
Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles über mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete für die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erhöht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.
Planning Principles for Integrating Community Empowerment into Zero-Net Carbon Transformation
(2023)
The adoption of the UN 2030 Agenda and the Sustainable Development Goals is a landmark in international sustainability politics. For example, Europe has set ambitious targets to achieve 100 climate-neutral and smart cities by 2030. However, numerous case studies from different countries have found that accelerating the transition to net-zero carbon emissions is easily hampered by the lack of a coherent systems framework, and that implementation gaps remain at the community level. These barriers are often due to a lack of an adequate end-user (i.e., household) input and early planning participation. This work therefore aims to improve on conventional planning methods that do not reflect innovative technologies with uncertainty and may not be applicable due to the lack of community empowerment, which is a dynamic learning and intervention opportunity for end-users at different planning stages (i.e., outreach, survey, planning, implementation, management, and maintenance). Using the lessons learned from participatory action research, whereby the author was involved as a project director throughout the planning and design process, we identified a
six-step cycle principle. The steps are (1) collective action commitments, (2) local values and resource identification, (3) carbon footprint inventory, (4) optimized integration of environment, economy, and energy action plans, (5) Flexible strategic energy system plans, and (6) digital performance monitoring. Ultimately, the outcomes provide application support for policymakers and planners and stimulate community engagement to contribute to the achievement of zero net carbon emissions.
The effect of both heat and mass transfer characteristic lengths (HTCL, MTCL) of two different adsorber plate heat exchangers (APHE), for application in an adsorption chiller, on the adsorption and desorption kinetics is investigated. Three representative test frames (TF1-TF3) are prepared to examine small-scale adsorbent samples of the microporous silica gel (Siogel of Oker-Chemie, Germany) applying the volumetric large-temperature-jump methodology at different operating conditions. Based on the obtained kinetic data, an analytical model has been developed to predict the specific cooling power (SCP) and the coefficient of performance (COP) of a single-bed adsorption chiller comprising the studied APHEs. It turned out that, within the tested range of HTCL and MTCL, it can be concluded that, the adsorption kinetics are mainly influenced by the MTCL, while the desorption kinetics are dominated by the HTCL of the adsorbent domain. Applying Siogel as loose pellets inside a newly introduced APHE results in of 423.3 and 182.7 W⋅kg−1, at the evaporator temperatures of 15 °C and 5 °C, respectively. Herein, the condenser and adsorber-end temperatures amount to 30 °C and the desorption-end temperature to 90 °C. The corresponding s amount to 0.50 and 0.40, respectively, which represent quite promising results for further design optimizations.
This paper proposes a multi domain physical model of permanent magnet synchronous machines, considering electrical, magnetic, thermal and mechanical effects. For each component of the model, the main wave as well as lower and higher harmonic wave components of the magnetic flux and the magnetic potential difference may be considered. The permanent magnets are modeled as discrete azimuthal segments in order to consider possible partial demagnetization effects. For each magnet segment a linearized temperature dependent B-H curve is considered. The main advantage of the presented model is that time transient operational behavior of a permanent magnet synchronous machine can be considered under various electrical, magnetic, thermal and mechanical conditions. The electromagnetic condition of surface magnet machine is compared with finite element analysis.
In this work a buck converter model for multidomain simulations is proposed and compared with a state-of-the-art buck converter model. In the proposed model no switching events are calculated. By avoiding the computation of the switching events in power electronic models the processing time of multidomain simulations can be decreased significantly. The proposed model calculates any operation point of the buck converter in continuous inductor current conduction mode (CICM) while considering the conduction losses and switching losses. It is possible to utilize the proposed modeling approach also for other dc-to-dc converter topologies. Laboratory test results for the validation of the proposed model are included.
The paper presents a concept and an implementation of Modelica simulation interaction using the operating system inter-process communication method of the Named Pipe. The main aim of this presented work is to implement a hardware-in-the-loop simulation (HILS) environment based on Dymola which runs on a normal Microsoft Windows Personal Com-puter. An energy storage test bench is connected by an ana-logue and digital data input/output card with the Dymola simulation computer. With this proposed system, particularly long-time simulations with sample rates up to 30 Hz can be executed very cost effective. Typical applications are simulations of drive cycles to test energy storage systems in electrified vehicles such as batteries or fuel cells. Other application ex-amples are the verification of battery models, thermal management models or battery management sys-tem (BMS) models. In this paper all methods used for implementation are described in detail. Especially the concept of inter-process communication and the concept for real-time and simulation time synchronization is discused. An application example which uses the provided concept is also shown at in this paper. In this example a longitudinal simulation of a vehicle is pre-sented. The startup phase of the internal combusting engine model and a short drive cycle in combination with a connected real battery is shown.
This paper deals with a simulative approach for investigating the impact of inverter pulse inhibition during field weakening operation of permanent magnet synchronous machines and asynchronous induction machines. The modelling and simulation language Modelica is used to design models for the vehicle, the electric machine and the inverter in different abstraction levels. It is shown that when using a permanent magnet synchronous machine, a sudden breakdown of the field weakening current causes induction of high voltages in the stator windings. Hence, the electric system of the vehicle has to be protected against the resulting high currents. Furthermore precautions have to be taken to avoid dangerous driving conditions because of high braking torques in an inverter fault operation mode. In the case of the asynchronous induction machine an inverter pulse inhibition poses no big problem, neither for the electric system of the vehicle, nor the driver.
This paper focuses on simulation of permanent magnet synchronous machine (PMSM) with fractional-slot windings (FSW) in Modelica. Modeling of the electrical machines with object-oriented approach is shortly described, and a new Modelica library for simulation of electrical machines is introduced. The results of simulation of PMSMs with fractional slot windings are presented and explained. Special attention is paid to the higher harmonics and subharmonics produced by the winding and their influence on machine operation.
Condition monitoring of rotor problems such as demagnetization and eccentricity in permanent magnet synchronous motors (PMSM) is essential for guaranteeing high motor performance, efficiency, and reliability. However, there are many limitations to the off-line and on-line methods currently used for PMSM rotor quality assessment. In this paper, an inverter-embedded technique for automated detection and classification of PMSM rotor faults is proposed as an alternative. The main concept is to use the inverter to perform a test whenever the motor is stopped, to detect rotor faults independent of operating conditions or load torque oscillations, which is not possible with motor current signature analysis (MCSA). The d-axis is excited with a dc+ac signal, and the variation in the inductance pattern due to the change in the degree of magnetic saturation caused by demagnetization or eccentricity is observed for fault detection. An experimental study on a 7.5kW PMSM verifies that demagnetization and eccentricity can be detected and classified independent of the load with high sensitivity.
Simulation is an indispensable tool for the engineering of systems containing electric drives. Depending on the design phase and the engineering task different levels of modeling details are required: proof of concept; investigation of energy and power consumption; design of control; etc. The new EDrives library provides three levels of abstraction for inverters: quasi static (neglecting electrical transients); averaging (neglecting switching effects) and switching – for serving different demands. The inverters can feed the machine models of the Modelica Standard Library: Modelica.Magnetic.FundamentalWave and the new Modelica.Magnetic.QuasiStatic.FundamentalWave. The EDrives library copes with arbitrary phase numbers and can be easily extended to develop new control algorithms. In this publication the structure of the library and the implemented control principles are presented. Furthermore; examples comparing the three different levels of abstraction are included.
The majority of industrial controlled induction machine drives are connected to the mains via a diode bridge. However; if reduction of harmonic currents and / or regenerative operation is desired; replacing the diode bridge by an active front-end (AFE) is required. This paper describes two models of an AFE: a power balance model disregarding switching effects; and an ideal switching model of a pulse width modulation (PWM) converter. Both models are controlled utilizing space phasors in a voltage oriented reference frame. Voltage oriented control (VOC) of the mains converter can be compared with field oriented control (FOC) of a machine converter. Design and parametrization of the main parts—synchronization with mains voltage; current controller and DC voltage controller—are described in detail. Additionally; simulation results proving the implementation and demonstrating possible investigations as well as an outlook on further enhancements are presented.
Sensorless PM-Drive Aspects
(2010)
The development procedure of permanent magnet drives for sensor less operation beginning from standstill under overload conditions has to consider different design aspects coevally. First, the robust rotor position sensing by test signal enforces a design with a strongly different behavior of the spatial dq-oriented differential inductance values. Therefore, the interior rotor magnet array arrangement is from principle predestinated for the controlled sensor less mode including standstill. Fortunately, in order to reduce costs, the distinct reluctance torque capability of such interior magnet arrangement is additionally used for a significantly increased torque by applying a pre-oriented stator current space vectors within the quasi-steady control.
Two state-of-the-art machine designs are mainly used in recent electric and hybrid electric vehicles: asynchronous induction machines with squirrel cage which are robust but need a current component to excite the magnetic field; and permanent magnet synchronous machines which rely on somehow more sensible parts but the magnets are able to excite a magnetic field without current. However; if speed gets high enough to reach the field weakening range; for both machine the field oriented control has to prescribe a field current sufficient to reduce the field not to exceed the voltage limits of the stator circuit. Especially for the permanent magnet synchronous machine this paper investigates whether it is possible to determine an optimal field current for every operation point to minimize either total current consumption or losses.
This paper presents a comprehensive computational fluid (CFD) model of a radial flux permanent magnet synchronous machine with interior magnets. In the CFD model the water jacket cooling and a simplified model of the topology of the distributed stator winding are considered. The heat sources of the CFD model are determined from a finite element analysis of the machine. The numerically determined temperature distributions of the machine are compared with measurement results from sensors located both in the stator and rotor. The particular focus of this paper is the analysis of the temperatures and the heat flow in the air gap and from the stator winding head and the rotor to the inner air.
The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous on-line monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance, L d , decreases with increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped, to measure L d for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An FE and experimental study on a 10hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability.
This paper presents two simulation models for two variants of a large chipper drive used in a paper mill. If a slip ring induction motor is used, the impact of a rotor circuit rheostat with respect to starting behavior and heavy duty load impulses can be examined. Furthermore a speed controlled squirrel cage induction machine will be investigated. The modeling language for both drives is Modelica. The simulation results for both drives are compared and discussed.
This paper presents a physical model of a squirrel cage induction machine with rotor topology. The machine is modeled in Modelica, an object oriented multi physical modeling system. The presented machine model is used to investigate electrical rotor asymmetries in induction machines. For the case of a single broken rotor bar a simulation model is compared with measurement results.
Innovative thermal model for the estimation of permanent magnet and stator winding temperatures
(2012)
In this paper an innovative thermal model for the determination of the temperatures of the permanent magnets and stator windings is presented. This model relies on one temperature sensor located in the stator core of the machine. The estimated stator winding and permanent magnet temperatures are determined by a simplified thermal lumped element network model with only two time constants. Due to the structure of the model and the measured stator core temperature the proposed thermal model is very robust. Distortion of the cooling circuit are inherently sensed such that the model can be used for the online prediction of temperatures. Experimental results based on an interior permanent magnet synchronous machine are presented to validate the presented model.
This paper introduces the new FundemantalWave library which is included in the Modelica Standard Library 3.2. The presented Modelica package provides models and components of rotating electrical three phase machines. The presented electrical machine models are fully compatible with the original Machines library of the electrical domain but rely on the concept of the magnetic potential and magnetic flux fundamental waves. In this article; the connector concept; the components and electric machine models of the FundemantalWave package will be explained. Additionally; the didactic advantages and the flexibility of the proposed package in with respect to considering more enhanced and sophisticated effects will be discussed.
From the rating plate data of an induction motor the nominal efficiency can be determined. Without detailed knowledge of equivalent circuit parameters, partial load behavior cannot be computed. Therefore, a combined calculation and estimation scheme is presented, where the consistent parameters of an equivalent circuit are elaborated, exactly matching the nominal operating point. From these parameters part load efficiencies can be determined.
In this paper a new model for the estimation of the stator winding and rotor cage temperatures of induction machines is presented. This model can be used in series applications of machines operated under dynamic load conditions where stator and rotor temperature shall be monitored. The proposed model relies on a simplified lumped element thermal equivalent circuit model where the stator core temperature serves as input quantity. The great advantage of this model is that it covers ambient and cooling conditions inherently. This leads to great simplicity and robustness. The parametrization and validation of the model through experimental data is presented. Advantages, drawbacks and possible implementations are discussed.
Abstract Electric machine theory and electric machine simulations models are often limited to three phases. Up to the Modelica Standard Libray (MSL) version 3.2 the provided machine models were limited to three phases. Particularly for large industrial drives and for redundancy reasons in electric vehicles and aircrafts multi phase electric machines are demanded. In the MSL 3.2.1 an extension of the existing FundamentalWave library has been performed to cope with phase numbers greater than or equal to three. The developed machine models are fully incorporating the multi phase electric; magnetic; rotational and thermal domain. In this publication the theoretical background of the machines models; Modelica implementation details; the parametrization of the models and simulation examples are presented.
In the literature, the effects caused by a single or several adjacently broken rotor bars, or a broken end ring are thoroughly investigated. The phenomenon of various nonadjacently broken rotor bars has not been studied so far in detail. Since nonadjacently broken rotor bars may give rise to fault signatures, which are not directly related with the fault extent, it is important to understand the nature of multiple electrical rotor asymmetries in induction machines. The purpose of this paper is thus to investigate several combinations of electrical rotor asymmetries, to systematically elaborate the phenomena related to the broken bars and end rings. In this paper, a sophisticated simulation model and measurement results are used to analyze the phenomenon rotor fault.
For a totally enclosed fan-cooled induction machine, two methods of numerical analysis are compared with measurements. The first numerical method is based on computational fluid dynamics (CFDs) and the second one uses a thermal equivalent circuit (TEC). For the analysis based on CFD, a 3-D induction machine including housing is modeled. The numeric solution of the flow equations is determined for stationary temperature distributions. For the TEC, a discretized one-and-a-half-dimensional model of the induction machine is considered. With the TEC model, stationary and transient operating conditions can be simulated. Measurement results are determined by iron-copper-nickel sensors embedded in the stator winding and the housing, as well as by an IR sensor for measuring the rotor temperature. With these measurement signals, stationary and transient operating conditions can be analyzed. For stationary operating conditions, additionally, the housing temperatures are determined by an IR camera. The investigated simulation and measurement methods reveal different local and global temperatures, and thus, only certain aspects and characteristics of the obtained temperatures can be compared. Nevertheless, certain conclusions can be drawn from comparing these aspects considering the actual restrictions of each of the applied methods.
From the rating plate data of an induction motor the nominal efficiency can be determined. Without detailed knowledge of equivalent circuit parameters, partial load behavior cannot be computed. Therefore, a combined calculation and estimation scheme is presented, where the consistent parameters of an equivalent circuit are elaborated, exactly matching the nominal operating point. From these parameters part load
efficiencies can be determined.
A Practical Thermal Model for the Estimation of Permanent Magnet and Stator Winding Temperatures
(2014)
A thermal model for the determination of the temperatures of interior permanent magnets and stator windings is presented in this paper. The innovation of the model relies on one temperature sensor being located in the stator core of the machine. Such sensor is simple to implement in many applications such as traction or EV, where reliability is critical. The estimated stator winding and permanent magnet temperatures are determined by a simplified thermal lumped element network model with only two time constants. It is shown that the proposed thermal model is very robust due to the structure of the model and the measured stator core temperature. The distortion of the temperature estimates caused by the cooling circuit is inherently accounted for such that the model can be used for robust online prediction of temperatures. Experimental results based on a forced water-cooled interior permanent magnet synchronous machine setup are presented to validate the effectiveness of the presented model.
A Parametrization Scheme for High Performance Thermal Models of Electric Machines using Modelica
(2012)
Thermal models offer great advantages for enhancement of design, protection and control of electric machines. Detailed thermal models take a great number of time constants into account and provide accurate prediction of the temperatures. However, to parameterize such models detailed geometric data are needed. Whenever such detailed information is not available, or the performance of the detailed models is not satisfying, simplified thermal models as described in this paper are advantageous. The calculation of parameters is described in detail, in order to achieve best accordance with temperatures obtained from measurements or from simulations with detailed thermal models. Thermal resistances are calculated from end temperatures of a test run with constant load (and known losses). Thermal capacitances are obtained using optimization to minimize deviation of simulated and measured temperatures during the whole test run. The thermal model of an asynchronous induction machine with squirrel cage is coupled with an electrical model of the drive. For validation, simulation results of an optimally parameterized simplified model are compared with temperatures obtained by simulation of a detailed thermal model, which in turn has been validated against measurement results, both for continuous duty S1 and intermittent duty S6 (6 minutes no-load followed by 4 minutes of 140% nominal load). The deviations are not more than 4 K which is quite satisfying.
Entwicklung eines Experimentalsystems zur Validierung adaptiver Regelungen mit einem OEM-Steuergerät
(2014)
Im Rahmen des Kooperationsprojektes "ACES" (Integrated Adaption of Linear Controllers for Embedded Systems) ist ein Prüfstand zur Validierung adaptiver Regelungen entwickelt und aufgebaut worden, der das dynamische Verhalten eines Kfz-Antriebstrangs aufweist. Ziel ist es, verschiedene Adaptionsverfahren auf ihre Einsetzbarkeit in OEM-Steuergeräten, die im Automotive-Bereich auf breiter Basis verwendet werden, kostengünstig testen zu können. Das Problem der aktiven Schwingungsdämpfung in Kfz-Antriebssträngen mit unbekannten und veränderlichen mechanischen Parametern stellt eine Pilotanwendung dar. Ein leicht anpassbarer mechanischer Prüfstand dient hierbei als vereinfachtes Modell eines Antriebstrangs. Dieser ist Bestandteil eitles Experimentalsystems mit einer informationstechnischen Architektur, die einen Betrieb engebetteter Regelungssysteme auf verschiedenen Plattformen gestattet. Das flexible mechanische und informationstechnische Design des Experimentalsystems gestattet die Variation von Parametern der zu regelnden Applikation durch leicht austauschbare mechanische Komponenten und gezielte Einbringung von Störgrößen. Zudem kann die Berechnung der Regelungsarchitektur auf einem Industrie-PC oder einem Steuergerät erfolgen. Weitere Vorteile des entwickelten Experimentalsystems sind die Berücksichtigung von Effekten, die aus dem Verhalten realer Sensoren und der CAN-basierten Signalübertragung entstehen. Insbesondere der Einfluss von Wortbreite und Latenz übertragener Signale auf die Adaption von Regelungen kann mit Hilfe des vorgestellten Experimentalsystems eingehend untersucht werden.
Bei Ottomotoren mit Direkteinspritzung besteht beim Kaltstart, den Warmlaufphasen und auch durch den Einfluss anderer Parameter wie z. B. des Einspritzzeitpunkts oder des Einspritzdrucks die Problematik, dass Kraftstoff an die Zylinderlaufbahn aufgetragen wird und sich mit dem Motoröl vermischen kann. Eine Verstärkung dieses Kraftstoffauftrags ist unter anderem der Verschiebung der Motorbetriebspunkte zu höheren Mitteldrücken und damit einem Wirkungsgrad optimaleren Betrieb geschuldet. Eine Veränderung der physikalischen und chemischen Eigenschaften des Motoröls durch die Verdünnung mit Kraftstoff ist die Folge. Durch die Verringerung der Viskosität des Motoröls kann es zu einer verminderten Schmierwirkung des Öls kommen, die im schlimmsten Fall zur Schädigung des Motors führt. Existierende Offline-Analysemethoden die zeitintensive Laboranalysen nach sich ziehen, als auch Online-Messverfahren die nicht den technischen Anforderungen hinsichtlich Genauigkeit und einer kurzen Messdauer entsprechen, stellen aktuell die einzigen Messmethoden zur Bestimmung der Schmierölverdünnung dar. Durch neue Entwicklungstrends bei Ottomotoren ist es jedoch unbedingt notwendig, die Mechanismen des Kraftstoffein- und -austrags in das und aus dem Motoröl genauer zu untersuchen. Mit der an der OTH Regensburg neu entwickelten Messtechnik wurde eine Vorgehensweise erarbeitet, mit der die zeitlichen Verläufe des Kraftstoffein- und -austragsverhaltens bei Ottomotoren quantitativ in kurzer Zeit bestimmt und optimiert werden können.
Especially at cold start and the warm-up operation GDI engines have an issue with oil dilution. Parameters such as injection timing and injection pressure impact the entry of fuel in the engine oil as well. With the adjustment of engine operating points to higher mean effective pressures resulting in downsizing concepts also an additional increase of fuel entry occurs. Fuel gets into the oil pan and is mixed with the engine oil so that the physical and chemical properties of the engine oil are changed. With the reduction of engine oil viscosity due to fuel entry a reduced lubricating effect can be caused. In the worst case damage to the engine occurs, To determine oil dilution online and offline measurement methods exist. A rather long analysis time in the laboratory is a disadvantage of the offline methods. Online methods are not correlating with technical requirements in terms of accuracy and a short measurement time. New trends in the development of gasoline engines require investigations of fuel in oil sorption and desorption processes. A new measurement technique which is developed at the OTH Regensburg enables to determine quantitative fuel in oil sorption and desorption processes. With this technique a procedure was generated to measure the oil dilution at gasoline engines and optimize them in a short time.
Beitrag und Praesentationsmaterial eines Vortrags ueber differenzierende Kohlenwasserstoffanalytik im Dieselabgas bei verschiedenen Motorbetriebszustaenden. Mit einem neu entwickelten, hochgenauen HC-Sensor werden unverbrannte HC im Abgas untersucht. Die differenzierende Untersuchung erfolgt an einem Massenspektrometer, das mit chemischer Ionisation arbeitet. Die Molekuele Ethin, Ethen und Propen wurden gezielt betrachtet. Es zeigt sich, dass bei kalten Betriebsbedingungen diese drei Komponenten etwa die Haelfte der gesamten HC Konzentration ergeben. Ein weiterer Punkt ist die Regeneration des Dieselpartikelfilters.
In future energy systems with high shares of fluctuating renewable energy generation, electricity storage will become increasingly important for the utilization of surplus energy. The Power-to-Gas (PtG) technology is one promising option for solving the challenge of long-term electricity storage and is theoretically able to ease situations of grid congestion at the same time. This article presents the perspectives of PtG in an 85% renewable energy scenario for Germany, quantifying an economic optimum for the PtG capacity as well as an optimized spatial PtG deployment.
Differenzierte Kohlenwasserstoffanalytik im Dieselabgas bei verschiedenen Motorbetriebszuständen
(2014)
Die für Dieselfahrzeuge gesetzlich vorgeschriebenen Grenzwerte bezüglich der Schadstoffkomponenten Kohlenwasserstoffe und Kohlenmonoxid können nur durch den Einsatz eines Diesel-Oxidationskatalysators erfüllt werden. Um erhöhte Emissionen infolge eines geschädigten Katalysators zu vermeiden, gilt es, dieses abgasrelevante Bauteil auch während des Betriebes zu überwachen. Die zukünftigen gesetzlichen Anforderungen an die Überwachung erfordern ein Verfahren das eine zuverlässige und hochgenaue Diagnose zulässt. Deshalb entwickelt eine Forschungsgemeinschaft aus Industrieunternehmen und Hochschulen einen neuartigen Kohlenwasserstoffsensor zur hochgenauen Analyse von unverbrannten Kohlenwasserstoffen im Abgasstrang. Hierfür ist die Kohlenwasserstoffzusammensetzung des Dieselabgases bei verschiedenen Motorbetriebszuständen zu ermitteln. Zur differenzierten Untersuchung der Kohlenwasserstoffkomponenten wurde in der Arbeit ein Massenspektrometer eingesetzt, das mit chemischer Ionisation arbeitet. Anhand eines Abgasscreenings konnte eine Reihe von Kohlenwasserstoffen (Alkane, Alkene, Alkine, Alkadiene und aromatische Kohlenwasserstoffe) identifiziert werden, die typisch für das Dieselabgas stehen. Die Moleküle Ethin, Ethen und Propen wurden gezielt betrachtet. Die Ergebnisse zeigen, dass bei kalten Betriebsbedingungen diese drei Komponenten etwa die Hälfte der Gesamtkohlenwasserstoffkonzentration ergeben. Ein weiterer Punkt der Untersuchungen war die Diesel-Partikelfilter-Regeneration. Wie erwartet, lassen sich Kohlenwasserstoffmoleküle mit höheren Massen feststellen, die auf unverbrannten Dieselkraftstoff zurückzuführen sind. Anhand der Ergebnisse zeigte sich.dass sich das mit chemischer Ionisation arbeitende Massenspektrometer hervorragend für ein Abgasscreening eignet. Zahlreiche Kohlenwasserstoffe konnten identifiziert werden, die repräsentativ für das Dieselabgas stehen. Es sollten Moleküle bei verschiedenen Motorbetriebsbedingungen untersucht werden, die einen möglichst großen Anteil an der Gesamtkohlenwasserstoffkonzentration besitzen. Die Auswahl fiel aufgrund der gemessenen Massenspektren, vor und nach dem Diesel-Oxidationskatalysator, auf die Komponenten Ethin, Ethen und Propen. Zudem kann bei diesen Molekülen eine Masseninterferenz mit anderen Abgaskomponenten ausgeschlossen werden. Im unteren Teillastbereich und kaltem Motor machen diese Kohlenwasserstoffe bis zu 50%, gemittelt über alle Messstellen vor, im und nach dem Diesel-Oxidationskatalysator, der Gesamtkohlenwasserstoffkonzentration aus. Bei betriebswarmem Motor reduziert sich ihr Anteil auf ein Drittel Die höchste Konzentration unter den drei Komponenten besitzt dabei Propen. Mit steigendem Drehmoment nimmt der Anteil dieser drei Komponenten fortlaufend ab,was dafür spricht, dass Moleküle mit höheren Massen einen höheren Anteil einnehmen. Die Kohlenwasserstoff-Emissionen bewegen sich bei diesen Motorbetriebspunkten mit betriebswarmem Katalysator jedoch bereits bei sehr niedrigen Werten. Während der untersuchten Diesel-Partikelfilter-Regeneration mit späten Nacheinspritzungen zur Abgastemperaturerhöhung lassen sich Moleküle mit höheren Massen nachweisen. Diese sind typisch für die Reinkomponente Dieselkraftstoff. Der Anteil von Ethin, Ethen und Propen an der THC-Konzentration beträgt dann ca. 40%.