Sanitär- und Kommunaltechnik; Umwelttechnik
Filtern
Dokumenttyp
- Zeitschriftenartikel (3) (entfernen)
Sprache
- Englisch (3)
Referierte Publikation
- ja (3)
Schlagworte
- Bisphenol A (2)
- Abwasser (1)
- Antibody (1)
- Antikörper (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Endokriner Disruptor (1)
- Enzyme-Linked Immunosorbent Assay (1)
- Fluorescence Polarization (1)
- Freisetzung (1)
Organisationseinheit der BAM
BPA is a chemical commonly used in the production of polymer-based materials that can have detrimental effects on the thyroid gland and impact human reproductive health. Various expensive methods, such as liquid and gas chromatography, have been suggested for detecting BPA.
The fluorescence polarization immunoassay (FPIA) is an inexpensive and efficient homogeneous mix-and-read method that allows for high-throughput screening. FPIA offers high specificity and sensitivity and can be carried out in a single phase within a timeframe of 20–30 min. In this study, new tracer molecules were designed that linked the fluorescein fluorophore with and without a spacer to the bisphenol A moiety. To assess the influence of the C6 spacer on the sensitivity of an assay based on the respective antibody, hapten–protein conjugates were synthesized and assessed for performance in an ELISA setup, and this resulted in a highly sensitive assay with a detection limit of 0.05 µg/L. The lowest limit of detection was reached by employing the spacer derivate in the FPIA and was 1.0 µg/L, working range from 2 to 155 µg/L. The validation of the methods was conducted using actual samples compared to LC–MS/MS, which served as the reference method. The FPIA and ELISA both demonstrated satisfactory concordance.
One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC–MS/MS as reference methods, showing good agreement with both methods
Pharmacologically active compounds are often detected in wastewater and surface waters. The nonsteroidal anti-inflammatory drug diclofenac (DCF) was included in the European watch list of substances that requires its environmental monitoring in the member states. DCF may harmfully influence the ecosystem already at concentrations ≤ 1 μg L−1. The fast and easy quantification of DCF is becoming a subject of global importance. Fluorescence polarization immunoassay (FPIA) is a homogeneous mix-and-read method which does not require the immobilization of reagents. FPIA can be performed in one phase within 20–30 min, making it possible to analyse wastewater without any complicated pre-treatment. In this study, new tracermolecules with different structures, linking fluorophores to derivatives of the analyte, were synthesized, three homologous tracers based on DCF, two including a C6 spacer, and one heterologous tracer derived from 5-hydroxy-DCF. The tracer molecules were thoroughly assessed for performance. Regarding sensitivity of the FPIA, the lowest limit of detection reached was 2.0 μg L−1 with a working range up to 870 μg L−1. The method was validated for real wastewater samples against LC-MS/MS as reference method with good agreement of both methods.