We introduce a passive smart dust concept as a novel solution for environmental monitoring. Utilizing chemical reagents like colorimetric indicators and other chemosensors, these particles detect varying environmental conditions. We developed paper-based sensors that are both cost-effective and eco-friendly. In practical tests, these sensors, dispersed over a designated area, successfully identified hazardous substances by changing their color when exposed to acids or bases. This color change was remotely detectable using a drone-mounted color camera. The data thus obtained was processed through specialized software, accurately pinpointing areas of contamination. This method proves the efficacy and scalability of passive smart dust technology for real-time, environmentally sustainable remote sensing of hazardous materials
Use/distribution of cost-effective and biocompatible pieces of cellulose paper as passive optical chemosensors and readout by the camera system.
Modification of the paper surface using various chemically sensitive dyes (indicators) provides an optically detectable reaction and conclusions about the target substances and precise location.
Volatile organic compounds (VOCs) emitted by furniture and building materials can cause health issues. For an improvement of indoor air quality low emitting materials should be used. Quality assurance and –control (QA/QC) measures require an emission reference material (ERM) with a predictable emission rate of VOCs. The idea is to use porous materials as ERM, which store the VOCs inside their pores and emit them constantly.
Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule is a seemingly improbable event, on a closer look, it is almost inevitable that homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure, would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth.
Organotin compounds (OTCs) have been widely used in anti-fouling paints, pesticide formulations, and as stabilizers in polyvinyl chloride over the past century. In marine ecosystems, OTCs can cause severe damage to biodiversity, leading up to the extinction of vulnerable species. Due to the extensive use of tributyltin (TBT) as a biocide on ship hulls, it has been considered one of the most hazardous substances intentionally introduced into the aquatic environment. This resulted in a global ban on TBT-containing products in the 2000s. However, recent studies indicate the emerging presence of organotin pollutants.
OTCs are known to persist and accumulate in marine sediments, posing a long-term threat to the environment. These harmful substances can be set free and dispersed even after several decades. Therefore, analyzing sediment probes is imperative for a thorough monitoring of pollution. However, species-specific analysis of OTCs at required concentration levels in complex environmental matrices remains challenging. Chromatographic systems are commonly used for their analysis, but the required sample preparation is time-consuming and prone to contamination and analyte loss. The coupling of electrothermal vaporization and inductively coupled plasma-mass spectrometry (ETV/ICP-MS) demonstrates high potential as a rapid, convenient, and chemical-saving scanning tool for environmental samples.
This method enables the direct on-line fractionation of organic compounds from an inorganic fraction and provides element-specific detection at ultra-trace levels without complex sample preparation. Since OTCs are generally more toxic than ionic or elemental tin, analyzing them as a sum parameter is advantageous. Additionally, the determination of both organic and inorganic tin, rather than just organic tin, reveals valuable information about the fate of OTCs. The main challenge in obtaining accurate quantitative data using direct solid sampling techniques like as ETV/ICP-MS is applying a suitable calibration strategy. Our isotope dilution approach overcomes matrix effects in ETV/ICP-MS analysis and is compatible with commercial systems.
PFAS (Per- and polyfluoroalkyl substances) are a widespread and emerging environmental problem due to their longevity and ubiquitous spread. The common structural motif of this compound class is the fluorine – carbon bond on an alkyl backbone, which are known for their chemical inertness and combination of hydrophobicity and oleophobicity. The downside of those properties is the general lack of usable molecular interactions for adsorption to extract them from the environment. The notable exception to that inertness are fluorine – fluorine interactions, which are stronger, the longer the perfluorinated chain length is. Therefore, in this project we investigated the effect of fluorination, length and presence of a charge on the alkyl chain on an adsorber. Towards that goal, in total 16 different adsorber materials were synthesized (fluorinated/non-fluorinated; C4/ C6/ C8/ C10 ; positive charge/no charge) and tested in regard to their potential to adsorb PFOA and perfluoralkylic acids of differing chain lengths. The PFAS concentration was tested via LC-MS/MS to determine the adsorption rate on the various materials. Further work includes the transition from a target analytics to sum parameter analysis for future evaluation of adsorber materials in PFAS environmental samples like river samples. Therefore a quarterly sampling and extraction of spree surface water samples was planned.
Per- and polyfluoroalkyl substances (PFAS) have received global public attention because of their wide distribution in aquatic environments and potential adverse effects to humans and wildlife. Due to the lack of analytical standards and the enormous numbers of these compounds, current target-based methods (e.g., LC-MS/MS) are not suitable for the analysis of new/unknown PFAS and transformation products. Therefore, PFAS sum parameter analysis is becoming increasingly important. For PFAS determination of surface waters, solid phase extraction (SPE) is commonly implemented for clean-up and pre-concentration of samples.
Thus, within this work, single-layer SPE methods (based on Strata™-X, Strata™-X-AW, Strata™-NH2 and Oasis-HLB) were investigated for maximum PFAS coverage utilizing extractable organically bound fluorine (EOF) analysis. Thereby, the optimization procedure relied on the analysis of 3 surface water samples in Berlin, Germany, which were affected by the effluent discharge of wastewater treatment plants. To analyse the SPE elution profiles for EOF and inorganic fluorine, high resolution-continuum source-graphite furnace molecular absorption spectroscopy (HR-CS-GFMAS) and ion chromatography (IC) were used, respectively.
Highest EOF concentrations were achieved by using Strata-X/Strata-XAW as SPE sorbents and methanol as eluent. Furthermore, combinations of the most promising SPE sorbents were selected (X/XAW, XAW/X, HLB/X and WAX/GCB) to extract a wider range of PFASs. By comparing multi-layer SPE methods, lower EOF concentrations were obtained for all investigated combination phases compared to the analysed single phases. For the commercially available combination phase Strata-PFAS (WAX/GCB) for all three river water samples, lower EOF concentrations (1.5 times lower) were determined compared to Strata-X.
The results have shown that single-layer SPE systems are currently superior compared to combination phases for PFAS sum parameter analysis. The multi-layer SPE methods need further optimization regarding appropriate sorbent combinations, loading volumes and elution conditions. The developed single-layer SPE methods can help to elucidate pollutions hotspots and discharge routes.
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%.
Bacterial adhesion on surfaces of medical, water and food applications may lead to infections, water or food spoilage and human illness. In comparison to traditional static and macro flow chamber assays for biofilm formation studies, microfluidic chips allow in situ monitoring of biofilm formation under various flow regimes, have better environment control and smaller sample requirements.
In this work, a novel microfluidic platform is developed to investigate biofilm adhesion under precisely controlled bacteria concentration, temperature, and flow conditions. This platform central unit is a single-inlet microfluidic flow cell with a 5 mm wide chamber designed and tested to achieve ultra-homogenous flow in the central area of chamber. Within this area, defined microstructures are integrated that will disturb the homogeneity of the flow, thus changing bacterial adhesion pattern.
Here we present the monitoring of bacterial biofilm formation in a microfluidic chip equipped with a microstructure known as micro-trap. This feature is based on a 3D bacteria trap designed by Di Giacomo et al. and successfully used to sequester motile bacteria.
At first, fluorescent particles similar in size to Escherichia coli (E. coli) are used to simulate bacteria flow inside the flow cell and at the micro-trap. The turbulences induced by the trap are analyzed by imaging and particle tracking velocimetry (PTV). Secondly, the model strain E. coli TG1, ideal and well described for biofilm studies, is used to analyze biofilm formation in the micro-trap. Therefore, a stable fluorescent strain E. coli TG1-MRE-Tn7-141 is constructed by using Tn7 transposon mutagenesis according to the method described by Schlechter et al. Sequestering of E. coli cells within the micro-trap was followed using epifluorescence microscopy.
The novel microfluidic platform shows great potential for assessment of bacterial adhesion under various flow regimes. The performance of structural feature with respect to the generation of turbulences that promote or reduce bacterial adhesion can be systematically examined.
The combination of flow analysis and fluorescent strain injection into the microfluidic chip shows that the micro-trap is useful for capturing bacteria at defined positions and to study how flow conditions, especially micro-turbulences, can affect biofilm formation. It represents a powerful and versatile tool for studying the relation between topography and bacteria adhesion.
Der Vortrag beschreibt den Stand der Arbeiten an der BAM, Fachbereich Umweltanalytik zur Entwicklung von Sensoren für die Wasseranalytik. Er stellt die bisherigen Arbeiten da, die ausgehend von ELISAs, zunehmend portable Plattformen wie FPIA und LFIA umfassen. Beas-based Formate werden von mikrotiterplatten-basierten Techniken auf mikrofluidische Lab-on-Chip-Systeme übertragen, die bei geeigneter Miniaturisierung und Automatisierung als Sensorsysteme angesehen werden können. Der Vortrag endet mit einem Blick auf ein laufendes Monitoring-Projekt von anthropogenen Markern in Abwasser und charakterisiert die Treiber, die die Entwicklung von Sensoren für die Wasseranalytik in den letzten Jahren vorantreiben.