Visualization of surface modifications may be very challenging for coating/substrate systems of either almost identical optical constants, e.g. transparent films on substrates of the same material, or minor film thickness, substance quantity and affected area, e.g. ultra-thin or island films. Methods for visualization are optical microscopy (OM), imaging ellipsometry (IE), and referenced spectroscopic ellipsometry (RSE). Imaging ellipsometry operates at oblique incidence near Brewster angle of the bare, clean or unmodified substrate. In this configuration, reflected intensities are rather weak. However, the contrast to add-on and sub-off features may be superior. Referenced spectroscopic ellipsometry operates in a two-sample configuration but with much higher intensities. In many cases, both ellipsometric techniques reveal and visualize thin films, printed-pattern, laser-induced changes, and impurities better than optical microscopy. In particular for stratified homogeneous modifications, ellipsometric techniques give access to modelling and hence thickness determination. Modifications under investigation are polymer foil residue on silicon, laser-induced changes of ta-C:H coatings on 100Cr6 steel, imperfections of ta-C:H on thermal silicon oxide, degradation of glass, thin film tin oxide pattern on silicon, printed and dried pattern of liquids such as deionized water, cleaning agents, and dissolved silicone. © 2016 Elsevier B.V. All rights reserved.
Durch faseroptische Sensoren können Bauteile im Einsatz kontinuierlich überwacht und frühzeitig Informationen über Materialveränderungen gewonnen werden. Mittels einer magnetostriktiven Aktorschicht, welche den Sensor umhüllt, kann nun auch die korrekte Sensorfunktion jederzeit kontrolliert werden. Als Aktorschicht eignet sich galvanisch abgeschiedenes reines Nickel oder Nickel-Eisen in der Zusammensetzung 50:50. Um diese haftfest mit dem Sensor zu verbinden wurde ein ECD/PVD-Kombinationsschichtsystem entwickelt. Die mechanischen Eigenschaften der ECD-Schicht können sowohl mit einer auf die Fasergeometrie angepassten instrumentierten Eindringprüfung als auch einem 2-Punkt-Biegeversuch bestimmt werden.
Der Vortrag widmet sich der „Quantifizierung der Festigkeit von Kunststoffklebungen & -beschichtungen: Vorbehandeln, Kleben und Prüfen im OKTETT“ und beschreibt das Mehr-Proben-Konzept zur Herstellung und Prüfung von Klebeverbunden. Vorgestellt werden die Mehr-Proben-Klebevorrichtung sowie die Centrifugal Adhesion Testing (CAT) Technologie zur Bestimmung der Haft- und Klebefestigkeit von Beschichtungen (Al auf PP, SiO2 auf CR39).
Iron-doped SnO2 coatings were deposited in a 50 kHz DC-pulsed magnetron sputtering discharge. The pulses had a duration of 4 µs in selected gas mixtures from pure argon up to
60% of oxygen at a constant total pressure of 0.2 Pa. A single target of SnO2 with Fe inset was used. The mass spectrometry study detected the gas-related ions Ar+, O2+ and O+, where the last one becomes the dominant positive ion at higher oxygen contents. Atomic oxygen ions had a higher energy as it resulted from the collision-caused dissociation on the target surface. The tin-related species were detected as Sn+ and SnO+. SnO2+ species were not detected. The deposition rate decreased by using gas mixtures with oxygen as well as the corresponding amount of Sn-related species in the plasma. The increase of oxygen also increased significantly the sheet resistance of the films. The XPS study showed that the iron concentration decreased by using additional oxygen. But the O/Sn ratio in the coatings was constant, contrary to the increased FeO/Fe ratio in the films. An additional analysis of the coatings by spectroscopic ellipsometry has shown a dependence of the polarizability and the permittivity on the amount of oxygen used during the deposition. In contrast, the study has found no such dependence for the absorption of the layers.
Der Stand der Normung im Bereich der Oberflächentechnik wird zusammengefasst. Aktuelle Normungsvorhaben zur chemischen Oberflächenanalyse, Rastersondenmikroskopie, Nanotechnologie, Oberflächenmesstechnik im Mikro- und Nanobereich, für Anwendungen von Kohlenstoffschichten sowie von Mess- und Prüfverfahren für metallische und anorganische Überzüge werden vorgestellt. Ein Ringversuch zur Klassifizierung von Kohlenstoffschichten mittels Ellipsometrie wird diskutiert. Abschließend wird das DIN-Terminologie Portal erläutert.
Der Vortrag widmet sich dem „Ringversuch zur Klassifizierung von Kohlenstoffschichten mittels Ellipsometrie“ und beschreibt die experimentellen Eckdaten, die Ellipsometrie als Messmethode am Beispiel DLC auf Stahl, Proben vs. n-k Ebene vs. Ergebnisse des Ringversuches, messtechnische Bewertung des Ringversuches und normative Bewertung des Ringversuches sowie Schlussfolgerungen.
The comprehensive knowledge of material properties as engineered and the material behavior in use is of huge importance for the functionality and reliability of processes and products. Hence, the accurate determination of material properties is a prerequisite for the applicability of a given material. Nowadays, macroscopic product features are originated by material properties on the microscopic and nanoscopic scale. This is a general challenge for uncertainty budgets in measurement and testing based on a conformity assesment.
Testing labs accreditated according to DIN EN ISO/IEC 17025 have to meet these demands. This paper focuses on the measurement of physical quantities (measurand with value and unit) and on the testing of material properties (qualitative, semi-quantitative or quantitative characteristics) of solid state materials. For both measurement and testing, the expression of uncertainty according to GUM is essential. Regarding the object/sample one has to subdivide in surface and bulk features, from the measurement/testing point of view destructive vs. nondestructive procedures have to be distinguished. Moreover, direct mesurement/testing and model-based determination of quantities/properties of interest require different approaches regarding the expression of uncertainty. For surface quantities and properties as discussed here, further considerations have to be made with respect to localized (lateral extension, native or artificial) or stratified (homogeneity and isotropy) material features vs. mapping (integration area) and imaging (lateral resolution and field of analysis) specifications of the measurement/testing procedure.
The concept of uncertainty budgets and the expression of uncertainty is introduced and discussed in more detail for the nondestructive model-based determination of thickness by spectroscopic ellipsometry (SE), the destructive determination of adhesion by means of centrifugal adhesion testing (CAT). It is shown that the expression of uncertainty for these examples and real materials requires different approaches resulting in either quantitity values with unit or qualitative/quantititative attributes with calculated/estimated uncertainties in agreement with GUM.
The multiple-sample approach by means of centrifugal adhesion testing (CAT-technology) allows the determination of bonding strength of adhesive-bonded joints on a statistical basis of up to eight samples. Therefore, it is obvious to ensure the continuous handling and identical processing of an octet of samples within the entire process chain of wet-chemical cleaning, plasma-chemical pre-treatment, bonding of samples, and testing of bonding strength. Within the multiple-sample bonding set-up (MPKV-technology) a defined bonding pressure can be adjusted regardless the actual number of samples. A comparison of single- and multiple-sample approach is made for bonding strength of selected adhesives, double-sided adhesive tapes and different material combinations [stainless steel (V2A) vs. stainless steel, polyamide (PA), or polypropylene (PP)]. It is shown that both technologies improve reliability of results
The future commercial prospects for adhesive tapes are very good and its application range is very broad. From every-day-use in office, packaging, maintenance, and quick repair in workshops, it ranges from handicraft work, medical purposes and cosmetics up to workmanship. The study describes a new multi-sample approach in adhesive tape testing from theoretical background, preparation of test specimen for tensile as well as shear testing, detailed measurement procedures up to analysis and result interpretation. Various types of single and double-sided pressure sensitive adhesive tapes supplied by different manufacturers were investigated and compared
Der Vortrag widmet sich Haftung und Haftfestigkeit bezüglich Grundlagen, Einflussgrößen sowie Prüfverfahren und beschreibt die Punkte: Generische und spezifische Motivation, Einflussgrößen auf Haftfestigkeit und Haftung von Beschichtungen, Prüfverfahren zur quantitativen Bestimmung der Haftfestigkeit und zur qualitativen Klassifizierung bzw. semi-quantitativen Bewertung der Haftung im Einzelnen.
The validation of the plasma compatibility of particles is a prerequisite for their application in plasma dispersion layers. The goal is the realization of functional add-on features on surfaces, in films and coatings. Although intended applications primarily address nanoparticles, the compatibility tests were carried out at first with particles in the lower micrometer range in order to investigate material-, fluorescent marker- or surface-based degradation effects in a simple manner.
Plasma compatibility implies at least the short-term acceptance of charged species, plasma-UV radiation, vacuum and elevated temperatures. Otherwise, effects on geometrical dimensions, chemical bonds, fluorescence efficiency and plastic-elastic properties are expected.
The plasma compatibility of monodisperse fluorescent-labeled particles to microwave excitation was evaluated by means of microscopic and spectroscopic investigation methods (light, fluorescence, confocal, atomic force microscopy and FTIR). This study comprises particles of different materials (SiO₂, PMMA, PS, MF) and sizes (from 50 nm to 10 μm).
A special preparation technique ensures that smallest geometry changes of particles can be measured by atomic force microscopy. For the selected plasma conditions (P = 600 W, f = 2.46 GHz, d = 10 cm) and an exposure time of 10 minutes, the geometry of SiO₂ particles (approx. 1.7 μm) remains nearly unchanged, whereas PS particles shrink in diameter by 6% and PMMA particles by 11%. For selected core-particles (SiO₂, MF) with fluorescencemarked (rhodamine) shell-polyelectrolytes no remarkable plasma degradation of the fluorescence intensity was observed for the above mentioned plasma conditions, however a doubling of exposure time already results in a significant decrease in intensity. Two different injection systems have been studied for the particle injection into the plasma deposition process.
One of the selected systems also proves process compatibility regarding the expected pressure differences upon injection
The validation of the plasma compatibility of particles is a prerequisite for their application in plasma dispersion layers. The goal is the realization of functional add-on features on surfaces, in films and coatings. Although intended applications primarily address nanoparticles, the compatibility tests were carried out at first with particles in the lower micrometer range in order to investigate material-, fluorescent marker- or surface-based degradation effects in a simple manner.
Plasma compatibility implies at least the short-term acceptance of charged species, plasma-UV radiation, vacuum and elevated temperatures. Otherwise, effects on geometrical dimensions, chemical bonds, fluorescence efficiency and plastic-elastic properties are expected.
The plasma compatibility of monodisperse fluorescent-labeled particles to microwave excitation was evaluated by means of microscopic and spectroscopic investigation methods (light, fluorescence, confocal, atomic force microscopy and FTIR). This study comprises particles of different materials (SiO2, PMMA, PS, MF) and sizes (from 50 nm to 10 μm).
A special preparation technique ensures that smallest geometry changes of particles can be measured by atomic force microscopy. For the selected plasma conditions (P = 600 W, f = 2.46 GHz, d = 10 cm) and an exposure time of 10 minutes, the geometry of SiO2 particles (approx. 1.7 μm) remains nearly unchanged, whereas PS particles shrink in diameter by 6% and PMMA particles by 11%. For selected core-particles (SiO2, MF) with fluorescencemarked (rhodamine) shell-polyelectrolytes no remarkable plasma degradation of the fluorescence intensity was observed for the above mentioned plasma conditions, however a doubling of exposure time already results in a significant decrease in intensity. Two different injection systems have been studied for the particle injection into the plasma deposition process.
One of the selected systems also proves process compatibility regarding the expected pressure differences upon injection.