Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Erscheinungsjahr
- 2016 (15) (entfernen)
Dokumenttyp
- Vortrag (6)
- Zeitschriftenartikel (5)
- Beitrag zu einem Tagungsband (4)
Sprache
- Englisch (15)
Schlagworte
- Phase grating (3)
- Additive Fertigung (2)
- Talbot- Lau interferometry (2)
- Visibility (2)
- X-ray refraction (2)
- Zerstörungsfreie Prüfung (2)
- 3D Mikrostruktur (1)
- Analytical Science (1)
- Average phase stress concentrations (1)
- Beta-Eucryptite (1)
- Brittle materials (1)
- Ceramic materials (1)
- Ceramics (1)
- Characterization (1)
- Composite materials (1)
- Computed tomography (1)
- Computertomographie (1)
- Damage (1)
- Differential scheme (1)
- Directional interface variance analysis (DIVA) (1)
- Duplex stainless steel (1)
- Elastic-moduli (1)
- FFT periodogram (1)
- Fracture-Toughness (1)
- Hydrogen assisted cracking (1)
- Intergranular strength (1)
- Load Partition (1)
- Materials (1)
- Metal Matrix Composites (1)
- Metrologie (1)
- Microcracking (1)
- Micromechanics (1)
- Microstructure (1)
- Neutron Diffraction (1)
- Neutron diffraction (1)
- Neutronenbeugung (1)
- Non-destructive (1)
- Non-destructive testing (1)
- Nonlinearity (1)
- Phase-contrast X-ray imaging (1)
- Pores (1)
- Refraktion (1)
- Representative volume element (1)
- Röntgenrefraktion (1)
- Stress (1)
- Stress analysis (1)
- Stress– strain curves (1)
- Synchrotron CT (1)
- Synchrotron imaging (1)
- Synchrotron radiation (1)
- TF Material (1)
- Talbot-Lau interferometry (1)
- Thermal (1)
- Thermal-Expansion (1)
- Tomographie (1)
- X-ray (1)
- X-ray computed tomography (1)
- X-ray reefraction (1)
- grating (1)
- metal matrix composite (1)
- multiphase composite (1)
- refraction (1)
- topography (1)
Eingeladener Vortrag
- nein (6)
Young's modulus and Poisson's ratio changes due to machining in porous microcracked cordierite
(2016)
Microstructural changes in porous cordierite caused by machining were characterized using microtensile testing, X-ray computed tomography, and scanning electron microscopy. Young's moduli and Poisson's ratios were determined on similar to 215- to 380-mu m-thick machined samples by combining digital image correlation and microtensile loading. The results provide evidence for an increase in microcrack density and decrease of Young's modulus due to machining of the thin samples extracted from diesel particulate filter honeycombs. This result is in contrast to the known effect of machining on the strength distribution of bulk, monolithic ceramics.
Internal damage of an AlSi12CuMgNi alloy reinforced with planar random short fibres has been investigated after compression. This damage strongly influences the load partition between matrix and reinforcement. For fibres perpendicular to the applied load, breakage and interconnected cracks appear in significantly higher volume fraction than with fibres parallel to load.
Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect.
At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems.
We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes.
Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries.
Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect.
At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems.
We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes.
Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries.
The most substantial innovations in radiographic imaging techniques of the last two decades aim at enhanced image contrast of weakly absorbing micro and nano structures by taking advantage of X-ray refraction effects occurring at outer and inner surfaces. The applications range from fibre reinforced plastics to biological tissues. These techniques comprise, among others, X-ray refraction topography, diffraction enhanced imaging, phase contrast imaging, Talbot-Lau grating interferometry, and refraction enhanced imaging. They all make use of selective beam deflections up to a few minutes of arc: the X-ray refraction effect. In contrast to diffraction, this type of interaction has a 100 % scattering cross section, as shown experimentally. Since X-ray refraction is very sensitive to the orientation of interfaces, it is additionally a tool to detect, e.g., fibre or pore orientation. If the detector resolution exceeds the size of (small) individual features, one detects the integral information (of inner surfaces) within the gauge volume. We describe the above-mentioned techniques, and show their experimental implementation in the lab and at a synchrotron source. We also show strategies for data processing and quantitative analysis.
Neutron diffraction: the forgotten non-destructive technique for residual stress analysis … and more
(2016)
3-D Stress Analysis
(Bulk) Stress mapping
Thick (and thin) films & Interfaces
Bulk high temperature
Real time
In-situ testing: Large sample environment (Stress rigs, Furnaces, …)
Neutrons and Synchrotron Radiation allow all this because they are FASTER , DEEPER and MORE PRECISE than lab equipment
(Flux)(Energy)(Parallel Beam)
Microstructure-property connections for porous ceramics: The possibilities offered by micromechanics
(2016)
Microstructure of porous ceramics is highly “irregular”: it comprises pores and microcracks of diverse shapes and orientations.
This makes their quantitative modeling challenging, and one
often resorts to empirical relations containing Fitting Parameters and having somewhat uncertain range of applicability. We review the substantial progress made in modeling of “irregular” microstructures that does not seem to have been sufficiently utilized in the context of ceramics. We discuss the possibilities offered by micromechanics in developing microstructure–property relations for porous microcracked ceramics. After an overview of relevant micromechanics topics, we focus on several issues of specific interest for ceramics: nonlinear stress–strain behavior, effective elastic properties, and thermally induced microcracking. We discuss extraction of microscale Parameters (such as strength of the intergranular cohesion, density of cracks and pores, etc.) from macroscopic data and identify the extent of uncertainty in this process. We also argue that there is no quantitative correlation between fracturing process and the loss of elastic stiffness.
Talbot-Lau interferometry provides X-ray imaging techniques with significant enhancement of the radiographic contrast of weakly absorbing objects. The grating based technique allows separation of absorption, refraction and small angle scattering effects. The different efficiency of rectangular and triangular shaped phase gratings at varying detector distances is investigated. The interference patterns (Talbot carpets) are modeled for parallel monochromatic radiation and measured by synchrotron radiation. In comparison to rectangular shapes of phase gratings much higher visibility is obtained for triangular shapes which yield enhanced contrast of a glass capillary test specimen.
Complex materials (e.g., porous ceramics) need high resolution techniques at multi-scale levels. Microstructure is intimately linked to properties and performance. One technique (or even a few techniques) is not enough. X-ray refraction and CT are very powerful tools. Non-destructive characterisation and quantitative image analysis techniques (2D and 3D) are necessary to understand the anisotropy.
Average phase stress concentrations in multiphase metal matrix composites under compressive loading
(2016)
We develop a model to predict average over individual phases stress concentrations in a multiphase metal matrix composite under compressive loading. The model accounts for matrix plasticity through variation of the shear modulus with applied stress and for frac- ture of filler through change in the shape of the particles. Three micromechanical models are compared –non interaction approximation, Mori–Tanaka–Benveniste (MTB) scheme, and Maxwell scheme. Comparison with the experimental measurements of Cabeza et al. (2016) shows that Maxwell scheme generally predicts the stress concentration with satis- factory accuracy. Results of MTB scheme vary depending on the loading case and ignoring of the interaction leads to substantial overestimation of the stresses.