Reference materials are essential to analyze the impact of micro- and nanoplastics. The particle size D50 has been chosen as property of interest. They can be produced top-down by milling. For size separation down to a particle size D50 of 50 µm sieving is suitable while smaller particle sizes can be obtained by filtration. After production it is important to control the stability because microplastic in the size range below 10 µm tend to agglomerate.
Micro- and nanoplastic particles became a topic of public concern all over the world e.g. in water, soil, sludge and air. For a profound risk assessment, it is necessary to identify the origins, hotspots, or transport between different media. Therefore, a representative repeatable analysis is required and reference materials (RM) to proof and compare methods.
The basis of MNP investigations is a harmonized analysis which includes sampling, sample preparation and detection. In recent years, spectroscopic methods like µRaman and µFTIR for the determination of particle numbers or thermoanalytical methods like Pyrolysis gas chromatography/mass spectrometry (py-GC/MS) and Thermo extraction/ desorption gas chromatography / mass spectrometry (TED-GC/MS) for mass determination have proven to be particularly suitable.
The technical committees (TC) of ISO TC 61 “plastics” and TC 147 “water quality" are working on harmonisation processes on international level. For all standardization approaches, it is necessary that the detection methods and analysis processes can be validated. Therefore, BAM develops reference material for microplastic (MP) analysis for several years with focus on the most common polymers PE, PP, PS, PET and PA.
MP particles with a close to reality fragment shape are obtained by cryomilling and sieving. For sample preparation purposes with mass detection methods MP particles are pressed into pills with a water-soluble matrix. Thereby losses due to sample preparation e.g. filtration are included in the verification of an analysis.
To ensure a constant quality throughout all MP RM batches the homogeneity and stability is controlled according to ISO Guide 35. Next to TED-GC/MS measurements particle size distribution, infrared spectroscopy and differential scanning calorimetry spectra are taken as accompanying parameters.
This presentation aims to introduce into the MP RM production process with ensured quality and special focus on pointing out customized setups for particle comminution, separation, and characterization for standardization.
Post-assembly modifications are efficient tools to adjust colloidal features of block copolymer (BCP) particles. However, existing methods often address particle shape, morphology, and chemical functionality individually. For simultaneous control, we transferred the concept of seeded polymerization to phase separated BCP particles. Key to our approach is the regioselective polymerization of (functional) monomers inside specific BCP domains. This was demonstrated in striped PS-b-P2VP ellipsoids. Here, polymerization of styrene preferably occurs in PS domains and increases PS lamellar thickness up to 5-fold. The resulting asymmetric lamellar morphology also changes the particle shape, i.e., increases the aspect ratio. Using 4-vinylbenzyl azide as co-monomer, azides as chemical functionalities can be added selectively to the PS domains. Overall, our simple and versatile method gives access to various multifunctional BCP colloids from a single batch of pre-formed particles.
A first tricolor fluorescent pH nanosensor is presented, which was rationally designed from biocompatible carboxylated polystyrene nanoparticles and two analyte-responsive molecular fluorophores. Its fabrication involved particle staining with a blue-red-emissive dyad, consisting of a rhodamine moiety responsive to acidic pH values and a pH-inert quinoline fluorophore, followed by the covalent attachment of a fluorescein dye to the particle surface that signals neutral and basic pH values with a green fluorescence. These sensor particles change their fluorescence from blue to red and green, depending on the pH and excitation wavelength, and enable ratiometric pH measurements in the pH range of 3.0−9.0. The localization of the different sensor dyes in the particle core and at the particle surface was confirmed with fluorescence microscopy utilizing analogously prepared polystyrene microparticles. To show the application potential of these polystyrene-based multicolor sensor particles, fluorescence microscopy studies with a human A549 cell line were performed, which revealed the cellular uptake of the pH nanosensor and the differently colored emissions in different cell organelles, that is, compartments of the endosomal-lysosomal pathway. Our results demonstrate the underexplored potential of biocompatible polystyrene particles for multicolor and multianalyte sensing and bioimaging utilizing hydrophobic and/or hydrophilic stimuli-responsive luminophores.
Biofilms are ubiquitous in nature and in the man-made environment. Given their harmful effects on human health, an in-depth understanding of biofilms and the monitoring of their formation and growth are important. Particularly relevant for many metabolic processes and survival strategies of biofilms is their extracellular pH. However, most conventional techniques are not suited for minimally invasive pH measurements of living biofilms. Here, a fluorescent nanosensor is presented for ratiometric measurements of pH in biofilms in the range of pH 4.5–9.5 using confocal laser scanning microscopy. The nanosensor consists of biocompatible polystyrene nanoparticles loaded with pH-inert dye Nile Red and is surface functionalized with a pH-responsive fluorescein dye. Its performance was validated by fluorometrically monitoring the time-dependent changes in pH in E. coli biofilms after glucose inoculation at 37 °C and 4 °C. This revealed a temperature-dependent decrease in pH over a 4-h period caused by the acidifying glucose metabolism of E. coli. These studies demonstrate the applicability of this nanosensor to characterize the chemical microenvironment in biofilms with fluorescence methods.
Solvent annealing is a versatile tool to adjust the shape and morphology of block copolymer (BCP) particles. During this process, polar solvents are often used for block-selective swelling. However, such water-miscible solvents can induce (partial) solubilization of one block in the surrounding aqueous medium, thus, causing complex structural variations and even particle disassembly. To reduce the complexity in morphology control, we focused on toluene as a nonpolar polystyrene-selective solvent for the annealing of striped polystyrene-b-poly(2-vinylpyridine) (PS-b-P2VP) ellipsoids. The selective stretching of PS chains produces unique asymmetric lamellae structures, which translate to an increase in the particle aspect ratio after toluene evaporation. Complete reversibility is achieved by changing to chloroform as a nonselective solvent. Moreover, surfactants can be used to tune block-selective wetting of the particle surface during the annealing; for example, a PS shell can protect the internal lamellae structure from disassembly. Overall, this versatile postassembly process enables the tailoring of the structural features of striped colloidal ellipsoids by only using commercial BCPs and solvents.