The results are based on data1. Figure 3 displays temperatures of the tank wall and of the gas phase over testing time. It can be seen that a complete coating strongly delayed the heating of tank wall and gas phase, whereas the partly coated tanks only had a minor influence on temperature development. There was no significant difference between a half coated and a thirdly coated tank measurable. Figure 4 shows the internal pressure of tanks over testing time. Only the fully coated tank enabled a low pressure over 90 min testing time. Hence, a complete coating is necessary to guarantee the fire safety of hazmat tanks and a partly coating is not sufficient.