Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
- Posterpräsentation (60) (entfernen)
Referierte Publikation
- nein (60)
Schlagworte
- Additive manufacturing (15)
- Additive Manufacturing (11)
- Computed tomography (11)
- Laser powder bed fusion (7)
- Computed Tomography (6)
- Residual stress (6)
- X-ray refraction (6)
- Microstructure (4)
- AlSi10Mg (3)
- Laser Powder Bed Fusion (3)
- Neutron diffraction (3)
- Residual Stress (3)
- Röntgenrefraktion (3)
- Synchrotron tomography (3)
- Ti-6Al-4V (3)
- X-ray fluorescence (3)
- AGIL (2)
- Absorption edge tomography (2)
- Additive Fertigung (2)
- Computertomographie (2)
- Dental materials (2)
- In situ heating (2)
- LTCC (2)
- Laser Beam Melting (2)
- MMC (2)
- Machine Learning (2)
- Metals (2)
- Metrology (2)
- Neutron Diffraction (2)
- Online Process Monitoring (2)
- Powder Bed Fusion (2)
- Selected Laser Melting (2)
- Selective laser melting (2)
- Synchrotron X-Ray Refraction (2)
- Synchrotron X-ray computed tomography (2)
- Thermally induced porosity (2)
- X-ray computed tomography (2)
- X-ray diffraction (2)
- 316L (1)
- 5G (1)
- AM IN718 (1)
- Additive Fertigung (AM) (1)
- Advanced manufacturing (1)
- Air Void System (1)
- Al alloy (1)
- AlSi10Mg alloy (1)
- Aluminium (1)
- Aluminium alloys (1)
- BAMline (1)
- Bench braking sequence (1)
- Bildverarbeitung (1)
- Bronze (1)
- Build Angle (1)
- Bulk properties ageing (1)
- CMAS (1)
- CMAS - Calcium-Magnesium-Aluminiumsilikat (1)
- Carbon Fiber Reinforced Plastics (1)
- Characterization (1)
- Crack evolution (1)
- Crack propagation (1)
- Creep (1)
- DED-L (1)
- DIC assisted compression (1)
- Damage (1)
- Damage mechanism (1)
- Data fusion (1)
- Dental material (1)
- Diesel (1)
- Diffraction Enhanced Imaging (1)
- EBSD analysis (1)
- EMN (1)
- Eigenspannung (1)
- Electron Backscatter Diffraction (1)
- Electron microscopy (1)
- European Metrology Network (1)
- Fe2TiO5 (1)
- Fiber reinforced dental post (1)
- Fiberglass composite (1)
- HDPE Sorption (1)
- Heat Treatment (1)
- Heat treatment (1)
- High Temperature Testing (1)
- Holz (1)
- IN 625 (1)
- IN718 (1)
- Implants (1)
- In situ tensile test (1)
- In situ testing (1)
- In-situ compression CT (1)
- In-situ heat treatment (1)
- In-situ tomography (1)
- In718 (1)
- JNP AdvManuNet (1)
- Kavitation (1)
- Keramik (1)
- L-PBF (1)
- L-PBF 316L (1)
- LMD (1)
- LPBF (1)
- LTCC multilayer (1)
- Lattice structure (1)
- Lightweight structures (1)
- Load Partition (1)
- Load history (1)
- Load transfer (1)
- Low Cycle Fatigue (1)
- Low cycle fatigue (1)
- MOF (1)
- Machine-Learning Segmentation (1)
- Mechanical Behavior (1)
- Metal Matrix Composite (1)
- Metal matrix composite (1)
- Metal organic framework (1)
- Micro computed tomography (1)
- Mikro-CT (1)
- Mikrostruktur (1)
- Neutronbeugungsverfahren (1)
- Non-destructive testing (1)
- Numerische Simulation (1)
- Polyamid 12 (1)
- Porosity (1)
- Porosity growth (1)
- ProMoAM (1)
- Propagation modes (1)
- Prozessmonitoring (1)
- Residual stress measurements (1)
- Residual stress state (1)
- Roughness (1)
- Röntgen-Refraktion (1)
- Röntgenbeugung (1)
- SLM (1)
- SXRR - Synchrotron X-ray Refraction Radiography (1)
- Scaffold (1)
- Selective Laser Melting (1)
- Semi-metallic friction material (1)
- Stainless Steel (1)
- Subgrain structure (1)
- Synchrotron CT (1)
- Synchrotron Tomography (1)
- Synchrotron X-ray Refraction (1)
- Synchrotron X-ray diffraction (1)
- Synchrotron X-ray refraction (1)
- Synchrotron X-ray refraction radiography (1)
- Synchrotron refraction radiography (1)
- TBC (1)
- Tensile Properties (1)
- Thermal arrier coatings (1)
- Thermal barrier coatings (1)
- Thermoelectrics (1)
- Thermography (1)
- Titanium (1)
- Torsional fatigue (1)
- Verbundwerkstoffe (1)
- Vitual computer tomography simulation (1)
- X-Ray Diffraction (1)
- X-ray Diffraction (1)
- Zahnmedizin (1)
- ZfP (1)
Organisationseinheit der BAM
- 8.5 Röntgenbildgebung (60) (entfernen)
Currently, mandatory requirements and recommendations for the detection of irregularities in laser beam welded joints are based on classic micrographs as set out in the standard ISO 13919-1:2019. Compared to classic micrographs, computed tomography enables a non-destructive, three-dimensional and material-independent mode of operation, which delivers much more profound results. Even in building material testing, methods with limited informative value can be checked and supplemented by CT examinations.
Ziel der Untersuchung: Evaluation der Eignung der Refraktions-Tomographie zur Analyse von Alterungserscheinungen innerhalb von adhäsiv verankerten Materialien vor und nach künstlicher Probenalterung.
Material und Methode: Vier humane mittlere Oberkieferfrontzähne wurden wurzelkanalbehandelt und ausgedehnte Klasse IV Defekte der Krone mit einer Aufbaufüllung aus dualhärtendem Komposit (Rebilda DC, VOCO) und einem Glasfaserstift (Rebilda Post, VOCO) restauriert. Alle Proben wurden feucht gelagert und in einer Synchrotron-Einrichtung (BAMline, BESSY II, HZB) mit einer Pixelgröße von 4,08 µm gescannt. Für diese Synchrotron-Refraktions-Tomographie (SXRCT) muss zunächst der Analysatorkristall (AK) zu einer Bragg-Reflexion (Beugung) angeregt werden, um eine SXRCT durchzuführen. Die SXRCT wird mit einer Transmissions-Tomographie (ohne AK) verrechnet. Darauf folgte eine künstliche Probenalterung mit 400.000 Kau- und 3.000 Thermozyklen (50N, 5-55°C). Anschließend wurden die Proben ein weiteres Mal gescannt. Die Datensätze beider SXRCT wurden mittels des „filtered back projection“ Algorithmus rekonstruiert, mit einer Bildanalyse-Software aufeinander registriert und ausgewertet. Hierdurch konnten die Veränderungen initialer Schädigungen analysiert werden.
Ergebnisse: Alle 4 Proben zeigten in den Scans Veränderungen des inneren Gefüges und an Grenzflächen nach Belastung. Es zeigten sich Ansammlungen von Wasser innerhalb eingeschlossener Hohlräume, subkritisches Risswachstum, Ausdehnung des Komposit und Quellung des Glasfaserstiftes um 0,4%. In den SXRCT Aufnahmen waren außerdem Dentintubuli, die bei Auflösungen von 4,08 µm sonst nicht deutlich sichtbar sind darstellbar. Dadurch konnte Eindringen von Wasser in die Tubuli im Anschluss an die Alterung belegt werden.
Zusammenfassung: SXRCT bietet die Möglichkeit, trotz einer vergleichbar geringen Auflösung, kleinste Strukturen und Veränderungen abzubilden. Dies ermöglicht unter anderem die detaillierte Analyse relativ großer Proben, wie eines vollständigen Zahnes in einem Scanvorgang.
In dentistry it is of great interest to achieve good sealing interzones between tooth tissue and restoration materials to avoid, e. g. secondary caries. μXRF and CμXRF are suitable to investigate the elemental composition at these interzones in respect to diffusion of elements. Synchrotron X-ray refraction radiography (SXRR) and μCT measurements deliver highly resolved structural information and make structural changes such as micro cracks within the filling and the tooth tissue visible. The presented measurements are part of the DFG funded project IXdent (Integrative X-ray techniques for chemical and structural characterizations of dental interzones.)
The depth-resolved CμXRF measurements are affected by absorption effects, making a quantitative investigation of the interzone in depth difficult. Full 3D quantification of heterogenous samples requires a complete model including dark matrix and density for each voxel. The combination of different techniques paves the way for a quantitative analysis of dental interzones.
LTCCs (Low-temperature co-fired ceramics) consist of three-dimensionally distributed, hermetically bonded ceramic and metallic components with structure sizes within [10; 100] µm. A non-destructive imaging technique is needed that provides 3D, sharp, high-contrast resolution of these structures, as well as porosity and defect analysis, which is made difficult by the very different X-ray absorption coefficients of the individual components of the microstructure. A HDR method is being developed that allows a combination of different tomograms, each with X-ray energies adapted to individual materials.
Die Brechung von Röntgenstrahlen (Röntgenrefraktion) an Grenzflächen zwischen Materialien unterschiedlicher Dichte ist analog zur Ablenkung von sichtbarem Licht an z.B. Glasoberflächen. Es gibt jedoch zwei wesentliche Unterschiede:
a) konvexe Grenzflächen verursachen Divergenz (d.h. der Brechungsindex n ist kleiner als 1), und
b) die Ablenkungswinkel sind sehr klein, und reichen von einigen Bogensekunden bis zu einigen Bogenminuten (d.h. n ist nahe bei 1);
Wie auch bei sichtbarem Licht ist die Ablenkungsrichtung der Röntgenstrahlen abhängig von der Orientierung der durchstrahlten Grenzfläche. Aufgrund dieser Eigenschaften eignen sich Röntgenrefraktionsmethoden hervorragend für:
a) die Erkennung und Quantifizierung von Defekten wie Poren und Mikrorissen und
b) die Bewertung von Porosität und Partikeleigenschaften wie Orientierung, Größe und räumliche Verteilung.
Wir zeigen die Anwendung der Röntgenrefraktionsradiographie (2,5D Technik) und der -tomographie (3D Technik) für die Untersuchung verschiedener Probleme in der Werkstoffwissenschaft und -technologie:
a) Sintern von SiC-Grünkörpern
b) Porositätsanalyse in Dieselpartikelfiltersilikaten
c) Faser-Matrix-Haftung in Metall- und Polymermatrixverbundwerkstoffen
d) Mikrorissbildung in Glaskeramik.
Wir zeigen, dass der Einsatz von Röntgenrefraktionsmethoden quantitative Ergebnisse liefert, die direkt als Parameter in Werkstoffmodellen verwendet werden können.
Al-Si alloys produced by Laser Powder Bed Fusion (PBFLB) allow the fabrication of lightweight free-shape components. Due to the extremely heterogeneous cooling and heating, PBF-LB induces high magnitude residual stress (RS) and a fine Si microstructure. As the RS can be deleterious to the fatigue resistance of engineering components, great efforts are focused on understanding their evolution in as-built state (AB) and after post-process heat treatments (HT). RS in single edge notch bending (SENB) subjected to different HT are investigated (HT1: 1h at 265°C and HT2: 2h at 300°C).
Als bildgebendes und zerstörungsfreies Verfahren eignet sich die Röntgen-Computertomographie (CT) insbesondere bei der Untersuchung von Kunst- und Kulturgütern. Die für Werkstoffprüfung und Materialanalyse konzipierten CT-Anlagen bieten dank hoher Röntgenleistung die Möglichkeit zusätzlich zu Holz, Keramiken und Kunststoffen auch stark schwächende Materialien, wie bspw. Metalle, zu durchdringen. Für eine hohe räumliche Auflösung im unteren Mikrometerbereich (2-200µm) sorgen entsprechend ausgelegte CT-Anlagen. In der Bundesanstalt für Materialforschung und -prüfung (BAM) stehen mehrere solcher CT-Anlagen für unterschiedliche Fragestellungen sowie Probengrößen und - materialien zur Verfügung. Einige Beispiele aus den vergangenen Arbeiten der BAM veranschaulichen das große Potential dieser Untersuchungsmethode.
Da bei einer CT-Messung in der Regel das gesamte Untersuchungsobjekt erfasst und in ein digitales Volumenmodell überführt wird, eröffnet sich für Archäologen und Restoratoren die Möglichkeit Untersuchungen hinsichtlich Materialzusammensetzung, Erhaltungszustand und Herstellungstechnik am virtuellen Objekt vorzunehmen, ohne die Originalsubstanz zu beeinträchtigen. Gegenüber der klassischen Radiografie, bei der nur eine zweidimensionale Abbildung erreicht wird, bietet die CT-Untersuchung die Möglichkeit innenliegende Strukturen dreidimensional zu erfassen. Die notwendige Bestimmung der Objektoberfläche erlaubt zudem die Erstellung eines Oberflächenmodells des untersuchten Gegenstandes. Damit lassen sich unter anderem mechanische Simulationen (Belastung, Durchbiegung, Durchströmung) durchführen. Der erzeugte Datensatz kann somit auch zur Herstellung eines Replikats im 3D-Druckverfahren genutzt werden. Anhand der Untersuchung der Mandoline von Smorsone wird gezeigt, wie eine CT-Messung durchgeführt wird und wie in dem anschließend rekonstruierten 3D-Datensatz mittels Koordinatenmesstechnik Maße (Abstände, Wandstärken, Winkel) exakt ermittelt werden können.
The availability of high-performance Al alloys in AM is limited due to difficulties in printability, requiring both the development of synergetic material and AM process to mitigate problems such as solidification cracking during laser powder bed fusion (LPBF). The goal of this work was to investigate the failure mechanism in a LPBF 7017 Aluminium alloy + 3 wt% Zr + 0.5 wt% TiC. The processing leads to different categories of Zr-rich inclusions, precipitates and defects.
Al-Si alloys produced by Laser Powder Bed Fusion (PBF-LB/M) techniques allow the fabrication of lightweight free-shape components. Due to the extremely heterogeneous cooling and heating, PBF-LB/M induces high magnitude residual stress (RS) and a fine Si microstructure. As the RS can be deleterious to the fatigue resistance of engineering components, great efforts are focused on understanding their evolution before and after post-process heat treatments (HT).
The interest to additively manufacture Nickel-based superalloys has substantially grown within the past decade both academically and industrially. More specifically, additive manufacturing processes such as laser powder bed fusion (LPBF) offer the ability to produce dense parts within a single manufacturing step. In fact, the exceptional freedom in design associated with the layer-based nature of the processes is of particular interest for the complex shapes typically required in turbine applications. In certain cases, the overall part performance can be achieved by tailoring the microstructure and the crystallographic texture to the specific application. However, these advantages must be paid at a price: the large local temperature gradients associated with the rapid melting and solidification produce parts that inherently contain large residual stress in the as-manufactured state. In addition, the presence of pores in the final part may further affect the in-service part failure. As among Nickel-based alloys Inconel 718 exhibits excellent weldability, this alloy has been widely studied in open research in the domain of LPBF. However, significant microsegregation of the heavier alloying elements such as Niobium and Molybdenum accompanied by dislocation entanglements may preclude the application of conventional heat treatment schedules. Therefore, different post processing heat treatments are required for laser powder bed fused Inconel 718 as compared to conventional variants of the same alloy.
In this study, we investigated two different heat treatment routes for LPBF Inconel 718. In a first routine, the samples were stress relieved and subsequently subjected to hot isostatic pressing (HIP) followed by a solution heat treatment and a two-step age (referred to as FHT). In a second routine, the samples were subjected to a single-step direct age post stress relieving heat treatment (referred to DA). We investigated the consequences of such heat treatment schedules on the microstructure, texture, and mechanical behavior. We show that by applying a DA heat treatment the typical columnar microstructure possessing a crystallographic texture is retained, while an equiaxed untextured microstructure prevails in case of an FHT heat treatment. We further evaluate how these heat treatments affect the mechanical behaviour on the macroscopic and microscopic scale.
The European Metrology Network (EMN) for Advanced Manufacturing has been established in June 2021. Currently nine EMNs focussing on different important topics of strategic importance for Europe exist and form an integral part of EURAMET, the European Association of National Metrology Institutes (NMI). EMNs are tasked to ▪ develop a high-level coordination of the metrology community in Europe in a close dialogue with the respective stakeholders (SH)
▪ develop a strategic research agenda (SRA) within their thematic areas
▪ provide contributions to the European Partnership on Metrology research programme Based on the analysis of existing metrology infrastructures and capabilities of NMIs, the metrology research needs for advanced manufacturing are identified in close cooperation with academic, governmental and industrial stakeholders.
Here, we report on the progress of the EMN for Advanced Manufacturing.
In Hinblick auf den austenitischen Stahl AISI 316L erzeugt das pulverbettbasierte selektive Laserstrahlschmelzen, als ein additives Fertigungsverfahren, kristallographisch texturierte und Multiskalige Mikrostruktur. Einerseits können diese Mikrostrukturen zu einer Verbesserung der statischen mechanischen Eigenschaften führen (z. B. zu einer höheren Streckgrenze). Andererseits stehen diesen Verbesserungen der mechanischen Eigenschaften hohe Eigenspannungen gegenüber, die sich nachteilig auf das Ermüdungsverhalten auswirken können. Zur Reduzierung der Eigenspannungen und der daraus resultierenden negativen Auswirkungen auf die Ermüdungseigenschaften, werden Bauteile nach der Herstellung typischerweise wärmebehandelt. In dieser Studie wurde eine niedrige Wärmebehandlungstemperatur von 450°C höher temperierten Behandlungen bei 800 °C und 900 °C gegenübergestellt. Diese Wärmebehandlungstemperaturen bilden die oberen und die untere Grenze ein Spannungsarmglühendes Materials, ohne die prozessinduzierte Mikrostruktur signifikant zu verändern. Zusätzlich bieten diese Temperaturen den Vorteil, dass sie eine übermäßige intergranulare Ausscheidung von Karbiden und TCP-Phasen vermeiden, die zu einer Sensibilisierung des Werkstoffes gegen korrosive Umgebungen führen würden. Die Auswirkungen der Wärmebehandlung auf das Gefüge wurden mittels Rasterelektronenmikroskopie (BSE und EBSD) untersucht. Die Relaxation der Eigenspannungen wurde vor und nach den jeweiligen Wärmebehandlungen bei 800°C und 900°C mittels Neutronenbeugung charakterisiert. Die Ergebnisse zeigen, dass die Proben nach der Wärmebehandlung bei 900 °C nahezu spannungsfrei sind, was mit der Auflösung der zellularen Substruktur korreliert.
The complexity of any microstructural characterization significantly increases when there is a need to evaluate the microstructural evolution as a function of temperature. To date, this characterization is primarily performed by undertaking elaborative ex-situ experiments where the material’s heating procedure is interrupted at different temperatures or times. Moreover, these studies are often limited to a region smaller than the representative elementary volume, which can lead to partial or even biased interpretations of the collected data. This limitation can be greatly overcome by using in-situ synchrotron X-ray refraction (SXRR). In this study, SXRR has been combined with in-situ heat treatment to monitor the porosity evolution as a function of temperature. This technique is a robust and straightforward method for time-resolved (3-5 min required per scan) evaluation of thermally induced microstructural changes over macroscopically relevant volumes.
The complexity of any microstructural characterization significantly increases when there is a need to evaluate the microstructural evolution as a function of temperature. To date, this characterization is primarily performed by undertaking elaborative ex-situ experiments where the material’s heating procedure is interrupted at different temperatures or times. Moreover, these studies are often limited to a region smaller than the representative elementary volume, which can lead to partial or even biased interpretations of the collected data. This limitation can be greatly overcome by using in-situ synchrotron X-ray refraction (SXRR). In this study, SXRR has been combined with in-situ heat treatment to monitor the porosity evolution as a function of temperature. It is shown that SXRR is a robust and straightforward method for time-resolved (3-5 min required per scan) evaluation of thermally induced microstructural changes over macroscopically relevant volumes.
Additively manufactured (AM) metallic sheet-based Triply Periodic Minimal Surface Structures (TPMSS) meet several requirements in both bio-medical and engineering fields: Tunable mechanical properties, low sensitivity to manufacturing defects, mechanical stability, and high energy absorption. However, they also present some challenges related to quality control. In fact, the optimization of both the AM process and the properties of TPMSS is impossible without considering structural characteristics as manufacturing accuracy, internal defects, and as well as surface topography and roughness. In this study, the quantitative non-destructive analysis of TPMSS manufactured from Ti-6Al-4V alloy by electron beam melting was performed by means of laboratory X-ray computed tomography (XCT).
Most of the Al alloys used in additive manufacturing (AM), in particular Laser Powder Bed Fusion (LPBF), do not exceed a strength of 200 MPa, whereas conventionally high-performance alloys exhibit strengths exceeding 400 MPa. The availability of such Al alloys in AM is limited due to difficulties in printability, requiring synergetic material and AM process development to satisfy harsh processing conditions during LPBF [1]. One approach is the addition of reinforcement to the based powder, allowing tailoring composition and properties of a Metal Matrix Composite (MMC) by AM. Still, the effect of the reinforcement on the resulting mechanical properties must be studied to understand the performance and limits of the newly developed material. The goal of this work was to investigate the failure mechanism of LPBF Al-based MMC material using in-situ Synchrotron X-ray Computed Tomography (SXCT) during mechanical testing.
In this work, we present the recent in-situ imaging developments at the BAMline (of synchrotron BESSY II, HZB), focused on the in-situ characterization and understanding of microstructural evolution of additively manufactured materials subjected to different environments. Two show cases are presented. In the first, X-ray refraction radiography (SXRR) was combined with in-situ heat treatment to monitor the microstructural evolution as a function of temperature in a laser powder bed fusion (LPBF) manufactured AlSi10Mg alloy. We show that SXRR allows detecting the changes in the Si-phase morphology upon heating using statistically relevant volumes. SXRR also allows observing the growth of pores (i.e., thermally induced porosity), usually studied via X-ray computed tomography (XCT), but using much smaller fields-of-view. In the second case study, XCT was combined with in-situ tensile test to investigate the damage mechanism in a LPBF Aluminum Metal Matrix Composite (MMC). In-situ SXCT test disclosed the critical role of the defects in the failure mechanism along with pre-cracks in the reinforcement phase of MMC. We found that cracks were initiated from lack-of-fusion defects and propagated through coalescence with other defects.
The subsurface residual stress in laser powder bed fused 316L structures was analyzed using X-ray diffraction (XRD) and layer removal. The influence of varying structure thicknesses was investigated. In this study the importance of combining surface roughness measurements with XRD was shown. Moreover, a clear relation between the structure thickness and the subsurface residual stress profiles was observed.
Nowadays, teeth are not directly extracted when tooth decay occurs. Whenever treatment of the affected tooth is possible, the carious region is replaced with a suitable filling. The filling material differs according to the position and size of the cavity. Since the restoration will remain in the tooth for many years, a well adhering and sealing interface between filling and healthy tooth tissue is needed. There is continuous development of new materials, but intensive studies of this complex interface between filling and healthy tooth are still lacking. Little is known about possible diffusion of elements from dental materials into healthy tooth tissue forming a socalled interzone with specific chemical and structural properties.
The combination of different analytical X-ray methods at synchrotron radiation facilities and in the laboratory enables an extensive structural and elemental investigation of such interzones. While X-ray fluorescence techniques and X-ray absorption spectroscopy yield elemental distributions and localized chemical speciation, X-ray diffraction, refraction and computed tomography add structural information to the full 3D analysis of model and real life tooth
samples. Within two DFG funded projects, we develop adapted methodologies and investigate
micro-chemical changes in interzones which we hypothesize may lead to sclerotic dentine.
Within the DFG project ‘IXdent’, first results have been achieved on 2D µXRF and X-ray refraction radiography measurements as well as combined 3D confocal µXRF and µXCT investigations at the interface between filling and bovine tooth tissue. The benefit of multiple analytical techniques and the combination of structural and elemental analysis will be demonstrated.