Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Erscheinungsjahr
- 2017 (429) (entfernen)
Dokumenttyp
- Vortrag (429) (entfernen)
Sprache
- Englisch (276)
- Deutsch (152)
- Mehrsprachig (1)
Referierte Publikation
- nein (429)
Schlagworte
- Korrosion (15)
- NIR (12)
- Eigenspannungen (11)
- Integrating sphere spectroscopy (11)
- Fluorescence (10)
- Nanoparticle (10)
- MAG-Schweißen (9)
- Upconversion (9)
- Quantum yield (8)
- Corrosion (7)
Eingeladener Vortrag
- nein (429)
The slip-rolling 2Disk tribometer from Optimol Instruments represented the technological evolution in tribotesting of the well-known AMSLER-type tribometer marketed in 1922. Both use two discs with the same outer diameter rolling against each other on their circumference. In the AMSLER, the lower disc dips into an oil reservoir, whereas in the 2Disk the oil is injected into the contact. The oil supply of the 2Disk is controlled by pump and temperature by a heat exchanger.
Structure elucidation of complex synthetic copolymers still represents a challenge. A one-dimensional separation technique cannot give the answer to the question: What are the molar mass distribution (MMD), the functionality distribution (FTD), the chemical composition distribution (CCD), the monomer sequence distribution (MSD), the topology differences within a single broad distributed polymer sample?
Is the coupling of liquid chromatographic separation techniques to mass spectrometry able to fill the gaps to a certain degree?
Different LC separation techniques as size exclusion chromatography (SEC), liquid adsorption chromatography (LAC), liquid chromatography at critical conditions (LCCC) and gradient elution liquid chromatography (GELC) combined with Matrix assisted Laser Desorption Ionization (MALDI) respectively Electrospray Ionization (ESI) Time of Flight (TOF) mass spectrometry are able to give information which otherwise are completely inaccessible. In some cases, CID tandem mass spectrometry is applied. Fragmentation of suitable precursor ions resulted in typical fragment ion patterns. This technique enables an additional information on e.g. sequences, structural defects and topology of complex polymer mixtures.
Often the deficiencies of stand-alone methods can be bridged. LC, blind to structural information needs mass spectrometry as one of the most powerful detectors able to give detailed information on e.g. the repeat units, functionalization or copolymer composition of the chromatographic separated constituents. A separation prior to MS reduces radical the dispersity which is one of the reasons for failing of MS. Also problems with different ionization probabilities in complex mixtures can partly be overcame.
The lecture will provide a series of examples where LC-MS has been applied to evaluate complex macromolecules and mixtures of these.
On- and offline coupling principles will be compared and the pros and cons of both mass spectrometric techniques will be discussed.
Laser metal deposition is described with its applications for additive manufacturing. The necessary process chain is discussed, with regard to weld bead dimensions and 3D build-up strategy. Metallurgical cross sections, x-ray and tensile tests are conducted. As demonstrative components, a gas turbine burner and a turbine blade are shown
Sowohl die 3D-Formbestimmung als auch die Thermografie sind Verfahren der Qualitätssicherung. Im vorgestellten Projekt wird versucht, die beiden Methoden zusammenzuführen.
Das Prinzip des für die Formbestimmung verwendeten 3D-Scanners beruht auf dem bereits bekannten Verfahren der Streifenlichtprojektion. Die Neuartigkeit des hier verwendeten 3D-Scanners besteht darin, dass nicht im sichtbaren, sondern im infraroten Spektralbereich gearbeitet wird. Dadurch wird es möglich, nicht die Reflexion, sondern die Wärmestrahlung des Prüfobjektes nach Absorption der eingebrachten Strahlung auszuwerten. Dies ermöglicht, auch optisch „nicht-kooperative“ Oberflächen zu erfassen. Die Anregung mit Wärmestrahlung stellt das Bindeglied zum Verfahren der aktiven Thermografie für die Detektion verdeckter Schäden dar. Bei letzterem Verfahren wird der Wärmestau über Defekten beim Eindringen der Wärme in die Tiefe des Materials gemessen. Dabei stellen Defekte eine Störung des 3D-Scan-Verfahrens dar, während umgekehrt unregelmäßig geformte Oberflächen das thermografische Verfahren erschweren, d.h. der Messeffekt eines der Verfahren ist ein Störeffekt für das jeweils andere Verfahren.
Es wird zum einen der Frage nachgegangen, inwieweit das 3D-Scan-Verfahren durch verdeckte thermische Defekte beeinträchtigt wird, und zum anderen die Möglichkeit untersucht, den vorhandenen 3D-Scanner auch für die aktive Thermografie einzusetzen. Es werden CFK-Proben mit künstlich eingebrachten thermischen Defekten untersucht und die Möglichkeiten und Grenzen der vorhandenen Messapparatur für die Defekterkennung aufgezeigt.
A bottom-up approach to study metal sulphides in brake friction materials at higher temperatures
(2017)
The impact of metal sulphides in brake friction materials on the friction behaviour of disc brakes was studied at two different temperatures and in two different atmospheres using a pin-on-disc device with powder supply. Powder mixtures were prepared by using a bottom-up approach, where magnetite is the main component, in which different metal sulphides are mixed in. At 400 °C, the resulting coefficients of friction are higher in air than in nitrogen atmosphere, which can be attributed to the generation of metal oxides and were confirmed by doing thermal analysis.
The purpose of the work presented in this paper is to analyze locally (at the element level) the contact behavior of a soil-pile contact problem. Therefore, a 2D shear test is modeled using the Finite Element Method. The formulation of a 4 nodded zero-thickness Interface element of Beer is chosen with a linear interpolation function. Four constitutive contact models adapted for contact problems have been implemented. The Mohr-Coulomb and Clough and Duncan models were chosen initially, due to the ease of implementation and few number of parameters needed. After, more complicated models in the framework of
elasto-plasticity such as: Lashkari and Mortara were implemented for the first time into the finite element code of the shear test problem. They include other phenomena such as:
relative density of soil, the stress level and sand dilatancy. From the results the relation between shear displacement and shear stress has been deduced. Finally, a discussion of the advantages and the drawbacks during computation of each model is given at the end.
A study on metal sulphides in tribofilms of modelled brake wear debris under variable humidity
(2017)
Metal sulphides are needed in brake pad formulations in addition to graphite to compensate the influence of different environments. The sensitivity to humidity differs a lot for each single constituent. Only one component is not sufficient for stabilising the COF and it is also necessary to add more components than only one metal sulphide to graphite. Furthermore, a good mixing process inside the third body during braking is necessary to prevent formation of solid lubricant films which are detrimental for braking. Nevertheless, not every metal sulphide acts as a solid lubricant but most of them have the ability for stabilizing the friction coefficient.
Im Rahmen eines BMWi Projekts der Fa. Innovent Jena, bei dem ein neuartiger optischer Sensor zur Bewertung der Oberflächenqualität und Reinheit von optischen Gläsern im Fokus stand, wurden die abbildende Ellipsometrie, die IR-Mikroskopie und die Weißlichtinterferenzmikroskopie als Referenzverfahren herangezogen. Mittels Brewster-Winkelmessungen konnten „Wolkenstrukturen“ identifiziert werden, die bei nachfolgenden Beschichtungsprozessen zu Schichtdefekten führen können. Außerdem wurden mittels Ellipsometrie Änderungen im Brechungsindex der Floatgläser (Luft- bzw. Zinnseite) nachgewiesen. Topographie Oberflächenmerkmale wie Welligkeit, Rauheit und Kreuzrillen konnten mittels Weißlichtinterferenzmikroskopie bzw. abbildender Ellipsometrie identifiziert werden.
There is an increasing interest in optical reporters like semiconductor and lanthanide-based nanocrystals with emission > 800 nm and recently also > 1000 nm for bioanalysis, medical diagnostics, and safety barcodes. Mandatory for the comparison of different emitter classes and the rational design of the next generation of reporters for the short wavelength infrared (SWIR) region are reliable and quantitative photoluminescence measurements in this challenging wavelength region. This is of special relevance for nanocrystalline emitters like semiconductor quantum dots and rods as well as for upconversion and downconversion nanocrystals, where surface states and the accessibility of emissive states by quenchers largely control accomplishable quantum yields and hence, signal sizes and detection sensitivities from the reporter side. Such measurements are currently hampered by the lack of suitable methods and standards for instrument calibration and validation as well as by the lack of quantum yield standards with emission > 800 nm and especially > 1000 nm.
In this respect, we present the design of integrating sphere setups for absolute and excitation power densitydependent measurements of emission spectra and quantum yields in the wavelength region of 650 to 1650 nm
including calibration strategies and first candidates for potential fluorescence standards. Subsequently, the photoluminescence properties of different types of nanocrystals are presented and discussed including absolute photoluminescence measurements of upconversion and down conversion emission in different solvents.