Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (404) (entfernen)
Sprache
- Englisch (337)
- Deutsch (64)
- Spanisch (2)
- Mehrsprachig (1)
Referierte Publikation
- nein (404) (entfernen)
Schlagworte
- Nanoparticles (32)
- Synchrotron (26)
- X-ray scattering (23)
- XPS (21)
- Mikroplastik (20)
- BAMline (18)
- Mechanochemistry (18)
- DNA (17)
- Geant4 (15)
- In situ (14)
Organisationseinheit der BAM
- 6 Materialchemie (404) (entfernen)
Thin mesoporous metal oxide films are versatile and attractive candidates for several energy applications like photovoltaics, electrolysis or batteries. Due to their high surface area and ordered pore structure, mesoporous metal oxides demonstrate higher activities. The performance of the porous films is affected by properties like size and shape of the mesopores as well as the crystallinity of the framework. The exact determination and metrological evaluation of the complex morphology of thin mesoporous films requires a new analytical approach employing to combined data of different analytical methods. In this contribution we present a novel evaluation procedure for spectroscopic ellipsometry (SE) to analyse thin mesoporous iridium oxide films.
Mesoporous iridium oxide films were prepared via dip-coating of a solution containing a triblock-copolymer as structure directing agent and an iridium precursor in ethanol. Deposited films were calcined in air at temperatures between 300 and 600 °C. Their morphology was studied with SEM and an electron probe microanalysis (EPMA) and correlated via SE with a Bruggeman effective medium approximation (BEMA). The developed SE model described the film thickness as well as the porosity.
...
The contribution will assess in detail the novel approach to analyse the morphology and porosity of thin metal oxide films with spectroscopic ellipsometry. Moreover, the advantages of the new developed approach will be discussed as well as combination of datasets from multiple measurements to development new methods for innovative energy technologies.
Surface analysis is still gaining importance, as most modern technology is in essence surface and thin film technology. In microelectronics and optics but also in many fields of energy storage and conversion, thin surface layers or structured surfaces are key components. Optical surface measurements are useful because of their reliability, robustness, and scalability – properties, which are especially desirable in a production environment. However, many of these methods take require considerable effort in data analysis. Spectroscopic ellipsometry (SE) is maybe the prime example of this class of methods. To combine the advantages of SE with metrological trueness and traceability, we combine it in a group of other methods, such as electron microscopy, instrumental surface analysis, X-ray diffraction.
This presentation will give an overview on the principles of SE, its available quantities and the general properties of this measurement technique. Several examples from current and past projects of BAM-6.7 will show how a measurement community involving ellipsometry can benefit many fields of interest, from polymer science to energy applications. In the context of creating a “measurement landscape”, standardisation and standard compliance play an important role. The efforts of BAM in standardisation and accrediting of ellipsometry will be shown demonstrating the possible impact on quality assurance in different fields of technology.
In well-annealed thin polymer films, with non-repulsive polymer/substrate interactions, an irreversibly adsorbed layer is expected to from. These adsorbed layers have shown greate potential for technological applications. However, their growth kinetics and molecular dynamics are still not fully understood. This is partly due to the hard accessibility of these layers in thin films. Here, the irreversibly adsorbed layers of homopolymer thin films are revealed by solvent-leaching experiments. First, the growth kinetics of these layers is investigated as a function of annealing time, annealing temperature, leaching time and the original filme thickness. The film thickness, topography and the quality of the adsorbed layer is controlled by Atomic Force Microscopy (AFM). Secondly, the molecular mobility of the adsorbed layer is investigated by Broadband Dielectric Spectroscopy (BDS). A recently developed nanostructured capacitor arrangement is employed to measure the layer with a free surface. The results are quantitatively compared and discussed with respect to recently published work.
Quantifizierung der Schädigung von DNA in wässriger Lösung unter direkter Elektronenbestrahlung
(2018)
To cure cancer radiation therapy is used to kill tumor cells.
It is based on radiation induced damage to biomolecules.
Especially DNA damage is of key interest due to its central role in apoptosis and mutation.
Because of the high amount of water in biological tissue, most of the damage is caused by the secondary particles produced by the inelastic scattering of ionizing radiation and water.
A detailed understanding of the underlying molecular processes under physiological conditions is the prerequisite to develop more efficient therapies.
Goal of this work is to quantify the DNA damage caused by ionizing radiation in dependence of the inelastic scattering events and the energy deposit within the microscopic target volume of biological relevance.
The irradiations have to be performed in liquid, under consideration of the chemical environment.
Therefore, a new combination of experiment and Monte-Carlo simulations was developed and tested.
To make it possible to irradiate liquids with electrons within scanning electron microscopes a new sample holder was constructed incorporating an electron transparent nanomembrane.
It makes it possible to irradiate DNA, proteins or cells at different pH, salinity and in the presence of cosolutes.
%The most important results of this work are as follows:
The median lethal dose for a model system of plasmid DNA and water was determined by the combination of experimental data, particle scattering simulations (Geant4-DNA) and diffusion calculations as D0.5=(1.7+-0.3) Gy.
From the convolution of plasmid positions and the spatially resolved energy deposit, as determined by electron scattering simulations, the histogram of the energy deposit within the target volume of the plasmids and the microscopic median lethal energy deposit was calculated as E0.5=6+-4eV.
It could be deduced that on average less than two ionization events are sufficient to cause a single-strand-break.
The relation of single-strand-breaks (SSB) to double-strand-breaks (DSB), which is of importance for microdosimetric modeling, was determined as SSB:DSB = 12:1.
The presented method for the determination of microscopic dose-damage relations was further extended to be applicable for general irradiation experiments.
It becomes independent of the type of primary radiation used, the experimental geometry, and the diffusional properties of the molecules under investigation.
This way different experimental systems with varying, inhomogeneous energy deposit characteristics become comparable with each other, which is not possible when only macroscopic averaged values are taken into account.
In addition, the radiation protection properties of the compatible solute ectoine, as well as its influence on the water properties and biomolecules were investigated.
%In addition, the influence of the compatible solute ectoine on water, biomolecules and its radiation protection properties were investigated.
Raman spectroscopy revealed a concentration dependent increase of the collective water modes in the OH-stretching region, which was found to be independent of the sodium chloride concentration.
Molecular dynamic simulations showed that the zwitterionic properties of ectoine lead to its half-chair conformation.
The hydrogen bonds in the first hydration shell are more stable and have an increased lifetime compared to the bulk water.
Irradiation experiments with DNA in the presence of 1M ectoine revealed an increase of the survival rate by a factor of 1.41 as compared to the absence of ectoine.
The protective properties of ectoine result from the increase of the inelastic scattering probabilities of low energy electrons at the acoustic vibrational modes of water and its properties as OH-radical scavenger.
This was shown by Raman spectroscopy and electron paramagnetic resonance measurements (EPR).
Photoelectron spectroscopy
(2018)
Gold ist eines der sieben schon im Altertum bekannten Metalle und wurde wg. seines Glanzes und seiner Seltenheit von alters her als Tauschmittel und zur Herstellung von Schmuck benutzt. Außerdem ist es einfach bearbeitbar und weitestgehend gegen chemische Einflüsse resistent. Die Untersuchungen von Gold mit synchrotronstrahlungsangeregter Röntgenfluoreszenzanalyse sind zerstörungsfrei und geben Auskunft über die in der untersuchten Probe vorhandenen chemischen Elemente. Bei den hier vorgestellten Untersuchungen an der BAMline stehen Fragestellungen wie Herkunft, Herstellungsverfahren und Zusammengehörigkeit von Goldfunden im Vordergrund. Die verschiedenen Fragestellungen werden an einer Reihe von Beispielen erläutert die vom Wikingerschatz aus Hiddensee über die Himmelsscheibe von Nebra bis hin zu Funden aus Ägypten langen. Zusätzlich werden die modernen Messmethoden vorgestellt, die am Synchrotron heutzutage zur Verfügung stehen.
X-ray absorption fine structure spectroscopy (XAFS) is a frequently employed technique in order to investigate structural composition and change of chemical compounds such as catalytic species. These structural properties are essential (i) to understand underlying reaction mechanism and (ii) to further improve the design of efficient catalysts.
This investigation is based on a newly developed XAFS setup comprising both time- and lateral-resolved XAFS information simultaneously in a single-shot (S2XAFS). The primary broadband beam is generated by a filter/X-ray-mirror combination (bandpass). The transmitted beam through the sample is diffracted by a convexly bent Si (111) crystal, producing a divergent beam. This, in turn, is collected by an area sensitive detector with a theta to 2 theta geometry. This facile, stable and scanningless setup was tested at the BAMline @ BESSY-II (Berlin, Germany).
This contribution focuses on further experimental optimizations allowing the characterization of supported vanadium oxide (VOx) based catalysts at the lower hard X-ray regime (5 to 6 keV). First S2XAFS measurements of these catalysts are presented herein. Supported VOx catalysts show promising results in the oxidation of methane to formaldehyde.
S2XAFS allows determining the structural composition of the metal (i.e. vanadium) based on a fast and smart setup. It is therefore an ideal tool to identify crucial roles of chemical compounds in catalytic reactions.
In-Situ SAXS Techniques
(2018)
Our project's aim is to enhance the capabilities of additive manufacturing techniques, where enabling a Two-Photon-Polymerization (TPP) 3D printer of producing arrays of precisely aligned nanoparticles is of an enormous value. As heterogeneous functional nanostructures with arrays of oriented nanoparticles are very promising in many fields; electrochemistry, energy storage, nanoelectronics among other vital fields.
The feasibility and the convenience of orienting nanoparticles using magnetic, electric fields and ultrasonic vibrations will be systematically investigated, using Small Angle X-ray Scattering (SAXS), since SAXS can provide detailed information about the orientation characteristics of nano-Ensembles. Corresponding to our prerequisites, a set ad hoc functional sample holders, sample stages and other In-Situ SAXS solutions were developed, and incorporated to be compatible with a state-of-the-arts SAXS machine, called Multi-scale Analyzer for Ultrafine Structures (MAUS).
The MAUS has been customized and engineered to serve as a miniaturized synchrotron, and that is exactly what we need.
Experiments attempting to orient superparamagnetic nanoparticles will be discussed, where the outcomes will not only help in understanding the mechanics of field-particle interactions, it will also help in further developing the adequate needed set of corrections to the SAXS data, that is especially regards oriented samples.