Analytische Chemie
Filtern
Erscheinungsjahr
- 2022 (615) (entfernen)
Dokumenttyp
- Vortrag (217)
- Zeitschriftenartikel (191)
- Posterpräsentation (89)
- Beitrag zu einem Tagungsband (59)
- Forschungsbericht (17)
- Sonstiges (15)
- Forschungsdatensatz (10)
- Buchkapitel (7)
- Dissertation (2)
- Handbuch (2)
Sprache
- Englisch (529)
- Deutsch (85)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (24)
- Digitalization (22)
- Certification (20)
- Conformity assessment (20)
- COVID-19 (19)
- Digital transformation (19)
- Sensor (19)
- Calibration (18)
- Conformity assessment body (18)
- Quality infrastructure (18)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (235)
- 1 Analytische Chemie; Referenzmaterialien (215)
- 6 Materialchemie (111)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (54)
- 8.4 Akustische und elektromagnetische Verfahren (53)
- 8.0 Abteilungsleitung und andere (52)
- 1.1 Anorganische Spurenanalytik (44)
- 8.5 Röntgenbildgebung (44)
- 6.1 Oberflächen- und Dünnschichtanalyse (42)
- 1.2 Biophotonik (40)
- 6.3 Strukturanalytik (40)
- 1.8 Umweltanalytik (35)
- S Qualitätsinfrastruktur (32)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (31)
- S.2 Digitalisierung der Qualitätsinfrastruktur (30)
- 1.3 Instrumentelle Analytik (28)
- 4 Material und Umwelt (27)
- 1.4 Prozessanalytik (26)
- 1.9 Chemische und optische Sensorik (21)
- 8.6 Faseroptische Sensorik (20)
- 1.7 Organische Spuren- und Lebensmittelanalytik (19)
- 6.6 Physik und chemische Analytik der Polymere (19)
- 1.5 Proteinanalytik (18)
- 1.6 Anorganische Referenzmaterialien (16)
- VP Vizepräsident (16)
- VP.1 eScience (16)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (15)
- 6.0 Abteilungsleitung und andere (14)
- 4.3 Schadstofftransfer und Umwelttechnologien (10)
- 4.2 Material-Mikrobiom Wechselwirkungen (9)
- 7 Bauwerkssicherheit (9)
- 9 Komponentensicherheit (9)
- 3 Gefahrgutumschließungen; Energiespeicher (7)
- 4.5 Kunst- und Kulturgutanalyse (6)
- 5 Werkstofftechnik (5)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (4)
- 9.0 Abteilungsleitung und andere (4)
- 5.1 Mikrostruktur Design und Degradation (3)
- 6.2 Material- und Oberflächentechnologien (3)
- 7.4 Baustofftechnologie (3)
- 7.6 Korrosion und Korrosionsschutz (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.0 Abteilungsleitung und andere (2)
- 2 Prozess- und Anlagensicherheit (2)
- 3.5 Sicherheit von Gasspeichern (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (2)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (2)
- 5.4 Multimateriale Fertigungsprozesse (2)
- 9.4 Integrität von Schweißverbindungen (2)
- P Präsident (2)
- P.0 Präsident und andere (2)
- S.1 Qualität im Prüfwesen (2)
- 2.1 Sicherheit von Energieträgern (1)
- 2.5 Konformitätsbewertung Explosivstoffe/Pyrotechnik (1)
- 3.2 Gefahrguttanks und Unfallmechanik (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 6.7 Materialsynthese und Design (1)
- 7.1 Baustoffe (1)
- 7.3 Brandingenieurwesen (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
- 7.7 Modellierung und Simulation (1)
- 9.2 Versuchsanlagen und Prüftechnik (1)
- 9.6 Additive Fertigung metallischer Komponenten (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (5)
Asymmetrically bridged aroyl-S,N-ketene acetals and aroyl-S,N-ketene acetal multichromophores can be readily synthesized in consecutive three-, four-, or five-component syntheses in good to excellent yields by several successive Suzuki-couplings of aroyl-S,N-ketene acetals and bis(boronic)acid esters. Different aroyl-S,N-ketene acetals as well as linker molecules yield a library of 23 multichromophores with substitution and linker pattern-tunable emission properties. This allows control of different communication pathways between the chromophores and of aggregation-induced emission (AIE) and energy transfer (ET) properties, providing elaborate aggregation-based fluorescence switches.
Laser metal deposition is a rapidly evolving method for additive manufacturing that combines high performance and simplified production routine. Quality of production depends on an instrumental design and operational parameters, which require constant control during the process. In this work, feasibility of using optical spectroscopy as a control method is studied via modeling and experimentally. A simplified thermal model is developed based on the time-dependent diffusion-conduction heat equation and geometrical light collection into detection optics. Intense light emitted by a laser-heated spot moving across a sample surface is collected and processed to yield the temperature and other temperature-related parameters. In the presence of surface defects, the temperature field is distorted in a specific manner that depends on shape and size of the defect. Optical signals produced by such the distorted temperature fields are simulated and verified experimentally using a 3D metal printer and a sample with artificially carved defects. Three quantities are tested as possible metrics for monitoring the process: temperature, integral intensity, and correlation coefficient. The shapes of the simulated signals qualitatively agree with the experimental signals; this allows for a cautious inference that optical spectroscopy can detect surface defects and, possibly, predict their characters, e.g., inner or protruding.
Global supply chains rely on the compliance and safety of their products, processes, and facilities. These vital services (often referred to as ‘quality assurance’ or ‘conformity assessment’ services) are provided by Conformity Assessment Bodies (CABs). This empirical study explores the impact of the COVID-19 pandemic on CABs as well as their response to the resulting challenges. Data was gathered through an online survey among all accredited CABs in Germany, which resulted in 555 valid responses. Taking a resilience perspective, we reveal that CABs were hit hard by the disruptions caused by the pandemic, albeit to different degrees, in part due to their type of services, size, and sectors served. Furthermore, we find that contingency plans do not directly cushion order declines (as the main indicator of the economic impact of the pandemic) but rather indirectly through helping CABs respond more quickly, which in turn mitigates their order declines. However, our results show that contingency plans can also have adverse effects if they hinder flexible reaction to the crisis. The findings of our study help managers and policymakers learn from the COVID-19 pandemic and improve the resilience of the conformity assessment sector and quality assurance in the event of future crises.
The services of Conformity Assessment Bodies (CABs) are essential to provide for trust in and safety of digital products and services by demonstrating that requirements from standards are met. Thus, it is vital that CABs are ready to fulfil their tasks also in the digital transformation, having the necessary capabilities and resources. Our study is the first to comprehensively assess the digital maturity in the CA industry and to provide some insights into the readiness of the industry to support and at the same time benefit from the digital age. To this end, we developed and implemented a digital maturity model tailored to the CA industry. In this paper, we present first results from our survey among 354 accredited CABs in Germany. With our research we contribute to better understand the digital transformation and maturation of CABs along distinctive stages. The findings suggest that the transformation process in the CA industry is just at the beginning, with the majority of CABs still in early stages of digital maturity. Also, only a few of them already exploit the latest digital technologies and applications like artificial intelligence, blockchain or big data analytics. Nevertheless, CABs regard digitalization as a big
opportunity – for themselves and their industry.
The finite volume method (FVM), like the finite element method (FEM), is a numerical method for determining an approximate solution for partial differential equations. The derivation of the two methods is based on very different considerations, as they have historically evolved from two distinct engineering disciplines, namely solid mechanics and fluid mechanics. This makes FVM difficult to learn for someone familiar with FEM. In this paper we want to show that a slight modification of the FEM procedure leads to an alternative derivation of the FVM. Both numerical methods are starting from the same strong formulation of the problem represented by differential equations, which are only satisfied by their exact solution. For an approximation of the exact solution, the strong formulation must be converted to a so-called weak form. From here on, the two numerical methods differ. By appropriate choice of the trial function and the test function, we can obtain different numerical methods for solving the weak formulation of the problem. While typically in FEM the basis functions of the trial function and test function are identical, in FVM they are chosen differently. In this paper, we show which trial and test function must be chosen to derive the FVM alternatively: The trial function of the FVM is a “shifted” trial function of the FEM, where the nodal points are now located in the middle of an integration interval rather than at the ends. Moreover, the basis functions of the test function are no longer the same as those of the trial function as in the FEM, but are shown to be a constant equal to 1. This is demonstrated by the example of a 1D Poisson equation.
Sound production due to main-flow oriented vorticity-nozzle interaction in absence of a net swirl
(2022)
The downstream acoustic response due to the interaction of main-flow oriented vorticity with a choked nozzle in a swirl-free flow was experimentally demonstrated. The response was obtained by means of impulsive radial air injection in the pipe upstream from the nozzle. The resulting downstream acoustic data are shown to obey a scaling rule that differs, from the one for swirl-nozzle interaction, which according to the literature is proportional to the square of the swirl number. In contrast, here evidence is presented that points to the scaling of main-flow oriented vorticity noise with the cross-sectional average of the square of the transversal velocity at the throat divided by the square of the critical sound speed.
In this study, the concept of a Zero Mass Flow Liner is evaluated. The concept enables impedance control by the induction of periodic bias flow through the perforated facing sheet of the liner. The periodic bias flow is generated by a secondary high amplitude acoustic actuation. By means of the periodic bias flow, the liner can be tuned to different operating points in a given range of grazing flow velocities. The equivalent fluid impedance model for perforated plates is modified to account for the effects of periodic bias flow and grazing flow. An optimization routine, based on a genetic algorithm, is implemented. The method is applicable to any liner concept and uses the impedance of the lined surface as boundary condition in a numerical simulation. Thereby, a set of liner parameters is derived in order to obtain the desired damping characteristics. Based on the results of the optimization, a Zero Mass Flow Liner is manufactured and consequently evaluated experimentally. The damping characteristics are evaluated in form of the dissipated energy along the lined surface. Prediction and measurements show agreement. The Zero Mass
Flow Liner delivers broad band dissipation of high peak value over a range of grazing flow Mach numbers. Under grazing ow conditions, the effect of periodic bias flow is reduced. This poses high energy requirements in high Mach number flow regimes which might restrict the applicability of the Zero Mass Flow concept to grazing flows of low Mach numbers.
Die zerstörungsfreie Prüfung von metallischen Bauteilen hergestellt mit additiver Fertigung (Additive Manufacturing - AM) gewinnt zunehmend an industrieller Bedeutung. Grund dafür ist die Feststellung von Qualität, Reproduzierbarkeit und damit auch Sicherheit für Bauteile, die mittels AM gefertigt wurden. Jedoch wird noch immer ex-situ geprüft, wobei Defekte (z.B. Poren, Risse etc.) erst nach Prozessabschluss entdeckt werden. Übersteigen Anzahl und/oder Abmessung die vorgegebenen Grenzwerte für diese Defekte, so kommt es zu Ausschuss, was angesichts sehr langer Bauprozessdauern äußerst unrentabel ist. Eine Schwierigkeit ist dabei, dass manche Defekte sich erst zeitverzögert zum eigentlichen Materialauftrag bilden, z.B. durch thermische Spannungen oder Schmelzbadaktivitäten. Dementsprechend sind reine Monitoringansätze zur Detektion ggf. nicht ausreichend.
Daher wird in dieser Arbeit ein Verfahren zur aktiven Thermografie an dem AM-Prozess Laser Powder Bed Fusion (L-PBF) untersucht. Das Bauteil wird mit Hilfe des defokussierten Prozesslasers bei geringer Laserleistung zwischen den einzelnen gefertigten Lagen unabhängig vom eigentlichen Bauprozess erwärmt. Die entstehende Wärmesignatur wird ort- und zeitaufgelöst durch eine Infrarotkamera erfasst. Durch diese der Lagenfertigung nachgelagerte Prüfung werden auch zum Bauprozess zeitversetzte Defektbildungen nachweisbar.
In dieser Arbeit finden die Untersuchungen als Proof-of-Concept, losgelöst vom AM-Prozess, an einem typischen metallischen Testkörper statt. Dieser besitzt eine Nut als oberflächlichen Defekt. Die durchgeführten Messungen finden an einer eigens entwickelten L-PBF-Forschungsanlage innerhalb der Prozesskammer statt. Damit wird ein neuartiger Ansatz zur aktiven Thermografie für L-PBF erforscht, der eine größere Bandbreite an Defektarten auffindbar macht. Der Ansatz wird validiert und Genauigkeit sowie Auflösungsvermögen geprüft. Eine Anwendung am AM-Prozess wird damit direkt forciert und die dafür benötigten Zusammenhänge werden präsentiert.
Compact NMR Spectroscopy in the field: A Versatile Tool for Automated Continuous-Flow Production
(2022)
Chemical companies must find new paths to successfully survive in a changing environment. The potential of digital technologies belongs to these. Flexible and modular chemical plants can produce various high-quality products using multi-purpose equipment with short downtimes between campaigns and reduce time to market for new products. Intensified continuous production plants allow for difficult to produce compounds.
Therefore, fully automated “chemical” process control along with real-time quality control are prerequisites to such concepts and thus should be based on “chemical” information. A commercially available benchtop NMR spectrometer was integrated to the full requirements of an automated chemical production environment such as, e.g., explosion safety, field communication, and robust evaluation of sensor data. It was thereof used for direct loop advanced process control and real-time optimization of the process. Field studies in modular and conventional production plant setups show promising results gaining process knowledge for further optimization. NMR appeared as preeminent online analytical method and allow using a modular data analysis tool, which even served as reliable reference method for further PAT applications (e.g. NIR spectroscopy). In the future, such fully integrated and intelligently interconnecting “smart” systems and processes can speed up the high-quality production of specialty chemicals and pharmaceuticals.