Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (45) (entfernen)
Referierte Publikation
- nein (45) (entfernen)
Schlagworte
- Traceability (19)
- Metrology (18)
- Absolute isotope ratio (13)
- Uncertainty (8)
- Isotope ratio (7)
- CCQM (5)
- Isotope reference material (4)
- Copper (3)
- Delta value (3)
- Isotope amount ratio (3)
- Isotope delta value (3)
- Isotope fractionation (3)
- Reference material (3)
- Triple isotope fractionation (3)
- CMC (2)
- Cement (2)
- Delta scale (2)
- Isotope dilution mass spectrometry (2)
- Measurement uncertainty (2)
- Metrology in chemistry (2)
- Purity (2)
- Purity assessment (2)
- metrology (2)
- traceability (2)
- Alzheimer disease (1)
- Archaeology (1)
- Archaeometry (1)
- Atomic weight (1)
- Atomic weights (1)
- Biodiesel fuel (1)
- Blank characterization (1)
- Boron isotopes (1)
- Calibration (1)
- Certification (1)
- Cheese (1)
- Circular economy (1)
- Comparability (1)
- Comparison (1)
- Conventional isotope ratio (1)
- Conventional isotope ratios (1)
- Counting detector (1)
- Curse tablets (1)
- Degree of equivalence (1)
- Delta values (1)
- Dementia (1)
- Detector deadtime (1)
- Dual mode detector (1)
- EURAMET (1)
- Emissionen (1)
- Fundamental science (1)
- Gravimtric isotope mixtures (1)
- Gypsum (1)
- Heavy metals (1)
- Human serum (1)
- ICP-MS (1)
- ICPMS (1)
- IDMS (1)
- Impurities (1)
- Interferences (1)
- Iron (1)
- Isotope delta (1)
- Isotope mixtures (1)
- Isotope purification (1)
- Isotope reference materials (1)
- Lead isotopes (1)
- Mangesium (1)
- Mass spectrometry (1)
- Matrix separation (1)
- Measurement space (1)
- Metal sublimation (1)
- Metrology in Chemistry (1)
- Molar mass (1)
- Noise (1)
- Optimization (1)
- PGE (1)
- Plant metabolism (1)
- Primary method of measurement (1)
- Provenance (1)
- Purity determination (1)
- Quality system (1)
- Re-evaluation (1)
- SI traceability (1)
- Silicon (1)
- Silver artefacts (1)
- Soil (1)
- Standard addition (1)
- Sulfur (1)
- Synthetic isotope mixtures (1)
- TCE (1)
- Terminology (1)
- Tetramethylammonium hydroxide (1)
- Transferrin (1)
- Zinc (1)
- key comparison (1)
- purity (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (45)
Technologie-kritische Elemente (TCE) sind unentbehrliche Materialien für High-Tech Produkte wie Smartphones, Notebooks und Monitors. Ihr Bedarf wird voraussichtlich aufgrund des gesellschaftlichen Wandels hin zu einer grünen Ökonomie exponentiell ansteigen. Dieser Wandel wird vor allem auch durch erneuerbare Energien und Elektromobilität geprägt (European Green Deal). Diese Entwicklung in Verbindung mit einer nahezu fehlenden TCE Produktion in Europa setzt den Markt unter Druck und führt zu steigenden Preisen. Die Sicherung des TCE Nachschubs wurde in der gegenwärtigen Gesundheitskrise noch dringender und wurde daher auch zu einem der Hauptthemen des COVID-19 Recovery Plan, der eine Stärkung der europäischen Resilienz und Autonomie zum Ziel hat. Ein nachhaltige Lösung ist das Recycling der Abfall- bzw. Wertstoffe und letztendlich eine Circular Economy. Allerdings ist die Analyse von Abfallströmen schwierig und erfordert geeignete analytische Lösungen, die SI-rückführbare und somit vergleichbare Messergebnisse im gesamten Recyclingprozess ermöglichen. Die dafür erforderlichen, für TCE zertifizierte, Referenzmaterialien und nötige standardisierte Verfahren fehlen bisher nahezu vollständig. In diesem Beitrag werden die analytischen Herausforderungen, wie z.B. die extreme Heterogenität der Materialien, Schwierigkeiten beim Probenaufschluss und das Fehlen von Referenzmaterialien diskutiert. Und es wird das EMPIR-Projekt MetroCycleEU vorgestellt, dessen Ziel es ist Referenz- und Routineverfahren für ausgewählte TCE (Co, Ga, Ge, In, Ta, Nd, Pr, Dy, Gd, La, Au, Pt, Pd, Rh) zu entwickeln und Referenzmaterialien für Platinen, LEDs und Li-Batterien bereitzustellen.
Determination of absolute (SI‐traceable) isotope ratios: The use of Gravimetric Isotope Mixtures
(2023)
The presentation is brief overview on how to use gravimetric isotope mixtures to determine SI traceable isotope ratios. There is no mass spectrometer on earth that directly measures isotope ratios. Mass spectrometers will always measure signal intensity ratios instead. The actual problem is that the measured intensity ratios differ more or less from the isotope ratios. The difference can be up to more than 10 % in case of lithium while it‘s below 1 % in case of the heavier elements like lead or uranium. Consequently, the signal intensity ratios are expressed for example in V/V depending on the type of mass spectrometer you are using, while the isotope ratios are expressed in mol/mol. This phenomenon is called Instrumental Isotopic Fractionation (or short IIF) but the more common name is still mass bias (even though this name is not entirely correct). To convert the measured into the isotope ratio usually a simple multiplication with a so-called correction (or short K) factor is done. Therefore, the problem is to determine the K factor. In absence of isotope reference materials the golden route is via gravimetric isotope mixtures, which will be explained within the presentation.
Detector deadtime
(2023)
A new method combining isotope dilution mass spectrometry (IDMS) and standard addition has been developed to determine the mass fractions w of different elements in complex matrices: (a) silicon in aqueous tetramethylammonium hydroxide (TMAH), (b) sulfur in biodiesel fuel, and (c) iron bound to transferrin in human serum. All measurements were carried out using inductively coupled plasma mass spectrometry (ICP–MS). The method requires the gravimetric preparation of several blends (bi)—each consisting of roughly the same masses (mx,i) of the sample solution (x) and my,i of a spike solution (y) plus different masses (mz,i) of a reference solution (z).
Only these masses and the isotope ratios (Rb,i) in the blends and reference and spike solutions have to be measured. The derivation of the underlying equations based on linear regression is presented and compared to a related concept reported by Pagliano and Meija. The uncertainties achievable, e.g., in the case of the Si blank in extremely pure TMAH of urel (w(Si)) = 90% (linear regression method, this work) and urel (w(Si)) = 150% (the method reported by Pagliano and Meija) seem to suggest better applicability of the new method in practical use due to the higher robustness of regression analysis.
CCQM-P149 is an attempt to obtain a snapshot on actual procedures the NMIs and DIs within CCQM-IAWG applied to the purity characterization of their “fit for purpose” elemental Standards. This presentation describes how the results of CCQM-P149 may be used to underpin calibration and measurement capabilities being claimed in the BIPM database.
An introduction into absolute isotope ratios is given, with application fields ranging from fundamental science to geochronology and forensics. This is followed by a proposal for developing new calibration approaches for obtaining absolute isotope ratios at unrivaled uncertainty levels. This new developments will set the basis for improvements in all scientific fields.
Absolute Isotope Ratios
(2018)
Measurement results and scientific models leading to important decisions in forensics, food fraud or climatology are based on isotope ratio data. Molar masses of multi-isotopic elements are as well based on isotope ratio data. Thus, in the case of Si, isotope ratios directly impact the redefinition of the SI base units kilogram and mole. Therefore, new strategies are required leading to new primary isotope reference materials, whose isotope ratios are traceable to the SI. This in turn will ensure the comparability of isotope ratio data and will render the traceability exception requested by the CCQM superfluous. Such new procedures will be developed for the key elements S, Si, Ca, Sr and Nd at relative uncertainty levels of ≤ 0.01 %.