Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (81)
- Vortrag (16)
- Sonstiges (7)
- Beitrag zu einem Sammelband (5)
- Posterpräsentation (4)
- Corrigendum (1)
- Forschungsbericht (1)
Sprache
- Englisch (115) (entfernen)
Schlagworte
- XPS (45)
- NEXAFS (21)
- Graphene (9)
- SIMS (9)
- ToF-SIMS (9)
- Metrology (8)
- Nanoparticles (7)
- Surface chemical analysis (7)
- AES (5)
- Lateral resolution (5)
Organisationseinheit der BAM
- 6 Materialchemie (57)
- 6.1 Oberflächen- und Dünnschichtanalyse (57)
- 4 Material und Umwelt (5)
- 4.1 Biologische Materialschädigung und Referenzorganismen (5)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 6.2 Material- und Oberflächentechnologien (1)
- 9 Komponentensicherheit (1)
- 9.0 Abteilungsleitung und andere (1)
Eingeladener Vortrag
- nein (16)
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and high-resolution scanning electron microscopy are well-acknowledged tools in materials characterization. The ability to map chemical species on the surface of an investigated sample with often low mass detection limits makes ToF-SIMS an essential tool in fields where many question marks concerning Degradation processes and damage mechanisms exist. The aim of this paper is to describe the power of data fusion of ToF-SIMS and high-resolution scanning electron microscopy results employing computational methods for multivariate data Analysis such as principal component analysis. As a case study the investigation of hydrogen distribution in an artificially charged Duplex stainless steel microstructure is presented aiming on a better understanding of hydrogen embrittlement.
Analytical routines for a comprehensive in-depth morphological, structural, and chemical characterization of functionalized TiO2 films by using different state-of-the-art analytical techniques are presented and discussed with the main objective to identify potential reference TiO2 coating parameters able to be certified at a later stage. TiO2 films fabricated by two different synthetic procedures as representative for two main large-scale applications were selected: (i) pulsed d.c. magnetron sputtering for photocatalytic applications and (ii) screen printing from preformed anatase nanoparticles. The screen-printed films were further loaded with a sensitizing dye for application as a dye-sensitized solar cell. Film properties such as microstructure and crystallographic texture of pulsed d.c. magnetron sputtering synthesized films were systematically studied by means of scanning nanobeam electron diffraction in a transmission electron microscope and the surface and inner morphology by scanning electron microscopy. The dye distribution over the depth of screen-printed TiO2 layers was analyzed before and after dye-loading by means of energy dispersive X-ray spectroscopy at scanning electronmicroscope, Auger electron spectroscopy and time-of-flight secondary ion mass spectrometry. The long-term goal of the present study is the improvement of quality of the TiO2 film parameters as measured by using different types of reference TiO2 coatings having specific parameters certified.
A comprehensive characterization of plasma modified polymer surfaces or plasma-polymerized thin films needs access to parameters as
- concentration of saturated/unsaturated carbon species (e.g. aromaticity) or other double bonds as C=N or C=O,
- branching, and
- losses of crystallinty or other degrees of structural order.
Furthermore the complex ageing phenomena of plasma modified polymers/plasma-polymers and the measurement of an in-depth distribution of chemical species are challenges for the analyst. The talk will display selected examples where such challenges have been met by using advanced methods of surface chemical analyses as Photoelectron Spectroscopy with variable excitation energy (“SyncXPS”), X-ray Absorption Spectroscopy (NEXAFS) at C, N and O K-edges and Time-of-Flight Secondary Mass Spectroscopy (ToF-SIMS) combined with Principal Component analysis (PCA).
In Near Edge X-Ray Absorption Fine Structure (NEXAFS) spectroscopy X-Ray photons are used to excite tightly bound core electrons to low-lying unoccupied orbitals of the system. This technique offers insight into the electronic structure of the system as well as useful structural information. In this work, we apply NEXAFS to two kinds of imidazolium based ionic liquids ([CnC₁im]⁺[NTf₂]⁻ and [C₄C₁im]⁺[I]⁻). A combination of measurements and quantum chemical calculations of C K and N K NEXAFS resonances is presented. The simulations, based on the transition potential density functional theory method (TP-DFT), reproduce all characteristic features observed by the experiment. Furthermore, a detailed assignment of resonance features to excitation centers (carbon or nitrogen atoms) leads to a consistent interpretation of the spectra.
The growing interest in artificial bioorganic Interfaces as a platform for applications in emerging Areas as personalized medicine, clinical diagnostics, biosensing, biofilms, prevention of biofouling, and other fields of bioengineering is the origin of a need for in Detail multitechnique characterizations of such layers and interfaces. The in-depth analysis of biointerfaces is of special interest as the properties of functional bioorganic coatings can be dramatically affected by in-depth variations of composition.
In worst cases, the functionality of a device produced using such coatings can be substantially reduced or even fully lost.
This survey will discuss current and emerging isothermal and rapid polymerase chain reaction (PCR) based nucleic acid amplification methods for patient near diagnostics. To assess the clinical need of rapid diagnostics for infectious diseases based on nucleic acid tests (NATs) we performed and analysed a questionnaire among laboratories participating in corresponding INSTAND ring trials for external quality assurance. The questions concerning new amplification technologies like isothermal nucleic acid amplification, potentially suited to significantly decrease turnaround times, were complemented by questions to evaluate the present status of NATs. Besides end-users, companies were also addressed by sending out a manufacturer specific questionnaire. Analysis of the answers from 48 laboratories in 14 European countries revealed that a much shorter turnaround time is requested for selected pathogens compared to about 2 h or longer when applying temperature cycling amplification, i.e. PCR. In this context, most frequently mentioned were MRSA, norovirus, influenza A and B viruses, cytomegalovirus (CMV) as well as hepatitis B virus (HBV) and hepatitis C virus (HCV). At present, 8% of the laboratories having participated in this survey apply isothermal amplification of nucleic acid to identify infectious pathogens.
CCQM has established a framework of comparisons to demonstrate the international comparability of chemical measurements. The key point is the establishment of comparable measurements, with traceability to internationally or nationally stated references. The Surface Analysis Working Group (SAWG) has been formally founded in 2003. CCQM ratified the group as a full working group of CCQM in April 2003 with these terms of reference:
- to develop pilot studies and carry out key comparisons of national measurement standards for surface and micro/nano-analysis;
- to assist in identifying and establishing inter-laboratory work to improve the traceability of surface and micro/nano-analysis;
- to establish and update a work plan to be adopted by CCQM;
- to discuss and review the scope of the working group and to liase with other working groups related to nanotechnology.
Following the 2015 meeting of the CCQM, the pilot study CCQM-P130 “WD and ED Electron Probe Micro Analysis on Au-Cu alloys” lead by BAM&NIST has been finalized. The Key Comparison K-129 “Measurement of atomic fractions in Cu(In,Ga)Se2 Films” lead by KRISS has made substantial progress and is about to be finalized. The new Key Comparison K-136 on “BET specific surface of ” lead by UNIIM&BAM has made strong progress in 2015 and will be finished in 2016.
The implementation of new 2-D materials based technologies in production processes requires the development of quality management tools. These have to be underpinned by appropriate measurements. Consequently there is a need for the development of the metrology for measurement methods, the development of certified reference materials (CRM) and finally standardization. This chain represents the ideal way to practically useful standards. The presentation will give an overview on the main players in the field and summarize the recent status of activities. At the highest level the metrology of chemical characterization of 2D materials is in the scope of the International Meter Convention, specifically the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM). Pre-standardization is an activity field of the Versailles Project on Advanced Materials and Standards (VAMAS). Standardization is mainly addressed by addressed ISO Technical Committees. A summary on available CRMs relevant to the characterization of nano materials has been prepared by BAM. Examples from the work of BAM’s Division 6.1 “Surface Analysis and Interfacial Chemistry” showcasing the characterization of chemically modified graphene surfaces are given and specific needs for the development of metrology are addressed.
In the discussion the audience is invited to define specific needs which will be streamlined to the respective bodies!
The quantitative determination of surface functional groups is approached in a straightforward laboratory-based method with high reliability. The application of a multimode BODIPY-type fluorescence, photometry, and X-ray photoelectron spectroscopy (XPS) label allows estimation of the labeling ratio, i.e., the ratio of functional groups carrying a label after reaction, from the elemental ratios of nitrogen and fluorine. The amount of label on the surface is quantified with UV/vis spectrophotometry based on the molar absorption coefficient as molecular property. The investigated surfaces with varying density are prepared by codeposition of 3-(aminopropyl) triethoxysilane (APTES) and cyanoethyltriethoxysilane
(CETES) from vapor. These surfaces show high functional group densities that result in significant fluorescence quenching of surface-bound labels. Since alternative quantification of the label on the surface is available through XPS and photometry, a novel method to quantitatively account for fluorescence quenching based on fluorescence lifetime (τ) measurements is shown. Due to the complex distribution of τ on high-density surfaces, the stretched exponential (or Kohlrausch) function is required to determine representative mean lifetimes. The approach is extended to a commercial Rhodamine B isothiocyanate (RITC) label, clearly revealing the problems that arise from such charged labels used in conjunction with silane surfaces.
Real Time Imaging of Deuterium in a Duplex Stainless Steel Microstructure by Time-of-Flight SIMS
(2016)
For more than one century, hydrogen assisted degradation of metallic microstructures has been identified as origin for severe technical component failures but the mechanisms behind have not yet been completely understood so far. Any in-situ observation of hydrogen transport phenomena in microstructures will provide more details for further elucidation of these degradation mechanisms. A novel experiment is presented which is designed to elucidate the permeation behaviour of deuterium in a microstructure of duplex stainless steel (DSS). A hydrogen permeation cell within a TOF-SIMS instrument enables electrochemical charging with deuterium through the inner surface of the cell made from DSS. The outer surface of the DSS permeation cell exposed to the vacuum has been imaged by TOF-SIMS vs. increasing time of charging with subsequent chemometric treatment of image data. This in-situ experiment showed evidently that deuterium is permeating much faster through the ferrite phase than through the austenite phase. Moreover, a direct proof for deuterium enrichment at the austenite-ferrite interface has been found.