Analytische Chemie
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (19)
- Vortrag (18)
- Zeitschriftenartikel (9)
- Posterpräsentation (4)
- Sonstiges (1)
Schlagworte
- Ferroelectret (11)
- Luftgekoppelte Ultraschallprüfung (11)
- Ultraschallwandler (9)
- Ferroelektret (8)
- Air-coupled ultrasound (7)
- Luftultraschall (7)
- Phased Array (7)
- Air-coupled ultrasonic testing (6)
- Atmospheric pressure plasma (6)
- Thermoakustik (6)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (51) (entfernen)
Eingeladener Vortrag
- nein (18)
Analog zu Blitz und Donner können elektrische Entladungen innerhalb eines Gasvolumens als akustische Quellen agieren und haben daher eine starke Verbreitung als diagnostische Methode (bspw. in der Raumakustik und bei der Ortung von Teilentladungen). Diese auf dem Prinzip der Thermoakustik beruhende Möglichkeit der Schallerzeugung und die damit verbundenen physikalischen Wechselwirkungen machen die Notwendigkeit einer mechanisch ausgelenkten Membran überflüssig. Dabei wird dem hochfrequenten Träger das Nutzsignal aufgeprägt, welches eine Volumenänderung des umliegenden Gases um seinen Ruhezustand verursacht. Durch die somit hervorgerufene zyklische thermische Wechselwirkung mit dem umliegenden Gasgemisch bedarf es daher ebenfalls keiner akustischen Anpassung. In den vorgestellten Ergebnissen wurde das Übertragungsverhalten eines Oberflächenplasmas (SDBD, surface dielectric barrier discharge) untersucht. Als Maß für den Wirkungsgrad und das Übertragungsverhalten des Aktuators wurden Klirrfaktor- und THD- Messungen und unter Variation der Eingangsleistungen durchgeführt. Durch die positiven akustischen Eigenschaften eröffnen sich neue Applikationen für den Einsatz von Plasmahochtönern wie bspw. zerstörungsfreie Werkstoffprüfung von Verbundsystemen und Klebeverbindungen im Automobilsektor oder im Bauwesen.
Air-coupled ultrasonic testing (ACUT) has experienced rapid growth within the last years. It is especially well suited to inspection of lightweight structures consisting of composite materials and adhesive joints. Uniform coupling and easy maintenance are its advantages compared to contact technique. However, the impedance mismatch between the transducer and air poses a major challenge to the development of ACUT transducers. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers. Their fabrication is difficult in handling and their signal-to-noise ratio sometimes not sufficient for various testing requirements. However, there are several innovative approaches using other materials and other physical principles to transmit and receive an ultrasonic pulse. We present a review of the latest advances in research on air-coupled transducers for non-destructive testing, including previously unpublished results. We recognize two major directions as most promising: ferroelectrets and thermoacoustic transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties. Their small acoustic impedance is matched to air better than matching layers applied in conventional air-coupled transducers. Applying bias voltage to a ferroelectret receiver is the latest development in this field, which increased the received signal by 12 to 15 dB. Thermoacoustic transducers use heat to initiate an ultrasonic wave, acting as transmitters. The working principle is known from nature as thunder and lightning: thermal energy of an electrically heated material, which can also be air, is converted into acoustic energy. Some thermoacoustic transmitters consist of a conductive layer with a thickness in the nanometer range deposited on a solid substrate. Another possibility is to use an electric spark. For the first time, measurements of the sound field of an electric spark up to 500 kHz were performed. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing.
Die physikalische Komplexität der Gasentladungen führt zu vielen Möglichkeiten für die Interaktion der Entladung mit ihrer Umgebung. Zu den typischen Anwendungen zählen Modifikationen der Materialoberflächen und Erzeugung von Ionen für Massenspektroskopie. Atmosphärendruckplasma generiert eine große Menge thermischer Energie wegen der Kollisionen in der Plasmarandschicht. Eine rasche Temperaturänderung kann in dem umgebenden Gas eine akustische Welle erzeugen, wie beim Blitz und Donner, was als thermoakustischer Effekt bekannt ist. Außerdem kann auch die Bewegung der Ladungsträger im elektrischen Feld, bekannt als ionischer Wind, eine akustische Welle erzeugen.
In diesem Beitrag werden Versuche mit akustischer Emission von Plasma bei dielektrischer Oberflächenentladung und bei Mikrohohlkathoden dargestellt. Es werden auch mögliche Anwendungen für Plasmadiagnostik, sowie für den Bau von Schallwandlern für den Hör- und Ultraschallbereich präsentiert. Verglichen mit anderen Methoden der Schallerzeugung, hat die thermoakustische Anregung den Vorteil, dass sie auch ohne eine schwingende Masse auskommt, womit eine große Bandbreite erreicht wird, sowie den Vorteil einer guten Anpassung der akustischen Impedanz.
Um den sicheren Betrieb von Windkraftanlagen zu gewährleisten, werden Rotorblätter nach der Fertigung und nach Reparatur mit verschiedenen zerstörungsfreien Verfahren auf Schaden untersucht. Bei der Fertigung von Blattschalen, die in einer Sandwich-Schalenbauweise gefertigt werden, entstehen Imperfektionen, die unter Belastung zu großen Rissen führen können. Zur Prüfung von Blattschalen wird unter anderem Ultraschallprüfung in Kontakttechnik eingesetzt. Um den Wartungsaufwand von Ultraschallanlagen zu reduzieren und um manche Kompositstrukturen vor Koppelmittel zu schützen, wird die Anwendung von Luftultraschall erforscht. Insbesondere große Fortschritte gibt es im Bereich der Entwicklung neuer Wandler.
In diesem Beitrag berichten wir über die Luftultraschallprüfung von Schalen für Rotorblätter. Es wurden typische Sandwichschalenstrukturen hergestellt und mit einem eigenentwickelten Schalenprüfstand unter simulierter Betriebsbeanspruchung belastet. Die in den Schalenprüfkörpern entstandenen Schäden wurden außerhalb des Prüfstandes mit Luftultraschall in Durchschallung untersucht. Es wurden fokussierende Wandler auf Basis von Ferroelektreten entwickelt und für diese Prüfungen eingesetzt. Mit zusätzlicher elektrischer Vorspannung konnte die Empfindlichkeit der Empfänger deutlich erhöht werden. Die nach dem Lastwechsel entstandenen Schäden in den Rotorblattschalen waren eindeutig zu detektieren.
Um den sicheren Betrieb von Windkraftanlagen zu gewährleisten, werden Rotorblätter nach der Fertigung und nach Reparatur mit verschiedenen zerstörungsfreien Verfahren auf Schaden untersucht. Bei der Fertigung von Blattschalen, die in einer Sandwich-Schalenbauweise gefertigt werden, entstehen Imperfektionen, die unter Belastung zu großen Rissen führen können. Zur Prüfung von Blattschalen wird unter anderem Ultraschallprüfung in Kontakttechnik eingesetzt. Um den Wartungsaufwand von Ultraschallanlagen zu reduzieren und um manche Kompositstrukturen vor Koppelmittel zu schützen, wird die Anwendung von Luftultraschall erforscht. Insbesondere große Fortschritte gibt es im Bereich der Entwicklung neuer Wandler.
In diesem Beitrag berichten wir über die Luftultraschallprüfung von Schalen für Rotorblätter. Es wurden typische Sandwichschalenstrukturen hergestellt und mit einem eigenentwickelten Schalenprüfstand unter simulierter Betriebsbeanspruchung belastet. Die in den Schalenprüfkörpern entstandenen Schäden wurden außerhalb des Prüfstandes mit Luftultraschall in Durchschallung untersucht. Es wurden fokussierende Wandler auf Basis von Ferroelektreten entwickelt und für diese Prüfungen eingesetzt. Mit zusätzlicher elektrischer Vorspannung konnte die Empfindlichkeit der Empfänger deutlich erhöht werden. Die nach dem Lastwechsel entstandenen Schäden in den Rotorblattschalen waren eindeutig zu detektieren.
Air-coupled ultrasonic testing (ACUT) has experienced rapid growth within the last years. It is especially well suited to inspection of lightweight structures consisting of composite materials and adhesive joints. Uniform coupling and easy maintenance are its advantages compared to contact technique. However, the impedance mismatch between the transducer and air poses a major challenge to the development of ACUT transducers. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers. Their fabrication is difficult in handling and their signal-to-noise ratio sometimes not sufficient for various testing requirements. However, there are several innovative approaches using other materials and other physical principles to transmit and receive an ultrasonic pulse. We present a review of the latest advances in research on air-coupled transducers for non-destructive testing, including previously unpublished results. We recognize two major directions as most promising: ferroelectrets and thermoacoustic transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties. Their small acoustic impedance is matched to air better than matching layers applied in conventional air-coupled transducers. Applying bias voltage to a ferroelectret receiver is the latest development in this field, which increased the received signal by 12 to 15 dB. Thermoacoustic transducers use heat to initiate an ultrasonic wave, acting as transmitters. The working principle is known from nature as thunder and lightning: thermal energy of an electrically heated material, which can also be air, is converted into acoustic energy. Some thermoacoustic transmitters consist of a conductive layer with a thickness in the nanometer range deposited on a solid substrate. Another possibility is to use an electric spark. For the first time, measurements of the sound field of an electric spark up to 500 kHz were performed. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing.
Air-coupled ultrasound (ACU) is increasingly used for automated and contactless inspection of large-scale composite structures as well as for non-destructive testing (NDT) of water-sensitive or porous materials. The major challenge to overcome using ACU in NDT is the enormous loss of ultrasonic energy at each solid-air interface caused by the high acoustic impedance mismatch. Resonant low-frequency piezoceramic transducers are specially designed to achieve high sound pressure levels. For an expanded use of this technique, however, the spatial resolution needs to be increased.
Recent studies of our collaborative research group demonstrated the successful application of a resonance-free, highly sensitive receiver that uses a Fabry-Pérot etalon instead of piezoceramic materials or membranes. However, to reach the full potential of this broadband small-aperture optical microphone, novel transmitter concepts have to be developed and evaluated for advanced NDT applications.
Different types of transmitter were tested in combination with the optical microphone acting as receiver and they were compared to conventional piezoceramic transducers in through-transmission mode. Monolithic carbon fiber-reinforced plastics (CFRP) and CFRP sandwich structures containing different defect types were inspected. Presented results are processed as C-scan images and further evaluated for spatial resolution, signal-to-noise ratio and sensitivity of each measurement setup. Novel transmitter concepts, such as ferroelectret and thermoacoustic emitters, show promising findings with a considerably improved time and spatial resolution for ACU-NDT.
We designed micro-hollow cathode discharge prototypes under atmospheric pressure and investi-gated their acoustic characteristics. For the acoustic model of the discharge, we correlated the self-organisation effect of the current density distribution with the ideal model of an acoustic membrane. For validation of the obtained model, sound particle velocity spectroscopy was used to detect and analyse the acoustic emission experimentally. The results have shown a behaviour similar to the ideal acoustic membrane. Therefore, the acoustic excitation is decomposable into its eigenfrequencies and predictable. The model was unified utilising the gas exhaust velocity caused by the electrohydrodynamic force. The results may allow a contactless prediction of the current density distribution by measuring the acoustic emission or using the micro-discharge as a tunable acoustic source for specific applications as well.
Der Umfang der durch Impacts in Faserverbundmaterialien erzeugten Schäden ist abhängig von der Energie des Impacts, von der Zusammensetzung und dem Aufbau der Faserverbundwerkstoffe und von der Geometrie der Bauteile und hier im Wesentlichen von der Dicke des Bauteils. Der zerstörungsfreie Nachweis dieser Schädigungen kann sowohl mit Ultraschallverfahren als auch mit Verfahren der aktiven Thermografie erfolgen. Ein Vergleich der Nachweisempfindlichkeiten dieser Verfahren für die unterschiedlichen Schädigungen wird in diesem Beitrag in Abhängigkeit vom verwendeten Faserverbundwerkstoff (CFK und GFK), der Dicke des Materials und von der Impactenergie durchgeführt. Ergänzt werden die im Anschluss an die Schädigung eingesetzten ZfP-Verfahren mit zeitlich hochaufgelösten Thermografiemessungen, die bereits während des Impacts aufgenommen wurden.
Modern and energy-efficient materials are essential for innovative designs for aerospace and automotive industries. Current technologies for rapid manufacturing such as additive manufacturing and liquid composite moulding by polymer Extrusion allow innovative ways of creating robust and lightweight constructions. Commercially available printing devices often use polylactide (PLA) or acrylonitrile butadiene styrene (ABS) as raw material. Therefore, parameters like the infill ratio, influencing the ability to resist mechanical stress, may have a beneficial impact on the lifetime of components.
These manufacturing technologies require a good knowledge about materials and even adapted non-destructive testing technologies and methods. Airborne ultrasonic testing has beneficial advantages for testing those lightweight constructions. It is a contact-free testing method, which does not require a liquid couplant. Therefore, it allows fast test cycles without any unwanted alternations of the material properties due to interactions with any coupling liquid. This contribution deals with the characterisation of printed specimens based on PLA by using airborne ultrasound and presents the current edge of non-destructive testing and evaluation using airborne ultrasonic transducers. The specimens, manufactured by polymer extrusion, are printed as thin plates. The infill ratio, as well as the material thickness, were varied to model density imperfections with different geometric shapes and properties. For better understanding of the limits of airborne ultrasonic testing in transmission, we compared own-developed transducers based on different physical principles: on ferroelectrets, on the thermoacoustic effect, as well as a new type of transducers based on gas discharges.
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.
Modern and energy-efficient materials are essential for innovative designs for aerospace and automotive industries. Current technologies for rapid manufacturing such as additive manufacturing and liquid composite moulding by polymer Extrusion allow innovative ways of creating robust and lightweight constructions. Commercially available printing devices often use polylactide (PLA) or acrylonitrile butadiene styrene (ABS) as raw material. Therefore, parameters like the infill ratio, influencing the ability to resist mechanical stress, may have a beneficial impact on the lifetime of components.
These manufacturing technologies require a good knowledge about materials and even adapted non-destructive testing technologies and methods. Airborne ultrasonic testing has beneficial advantages for testing those lightweight constructions. It is a contact-free testing method, which does not require a liquid couplant. Therefore, it allows fast test cycles without any unwanted alternations of the material properties due to interactions with any coupling liquid. This contribution deals with the characterisation of printed specimens based on PLA by using airborne ultrasound and presents the current edge of non-destructive testing and evaluation using airborne ultrasonic transducers. The specimens, manufactured by polymer extrusion, are printed as thin plates. The infill ratio, as well as the material thickness, were varied to model density imperfections with different geometric shapes and properties. For better understanding of the limits of airborne ultrasonic testing in transmission, we compared own-developed transducers based on different physical principles: on ferroelectrets, on the thermoacoustic effect, as well as a new type of transducers based on gas discharges.
Air‑coupled ferroelectret ultrasonic transducers for nondestructive testing of wood‑based materials
(2018)
Air-coupled ultrasound (ACU) is used in through transmission to detect delamination, rot, and cracks in wood without altering the structure permanently. Novel ferroelectret transducers with a high signal-to-noise ratio enable high-precision structure recognition. Transducers made of cellular polypropylene are quite suitable for ACU testing due to their extremely low Young’s modulus and low density resulting in a favorable acoustic impedance for the transmission of ultrasonic waves between the transducer and air. Thus, structures with great dimensions, with a thickness of up to 300 mm and material densities below 500 kg/m3, can be inspected. Promising results were obtained under laboratory conditions with frequencies ranging from 90 to 200 kHz. The advantage of ACU transducers is that they do not equire contact to the sample; they are accurate and cost-effective. Ultrasonic quality assurance for wood is an important avenue to increase the acceptance of wooden structures and toward sustainability in civil engineering in general.
High sensitivity is an important requirement for air-coupled ultrasonic sensors applied to materials testing. With a lower acoustic impedance than any piezoelectric material, charged cellular polypropylene (PP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric properties of charged cellular PP originate from their polarization, creating permanent internal voltage. The sensitivity of the sensor can be increased by applying additional dc bias voltage, as it has been done already for transmitters. This work presents the first ultrasonic sensor based on charged cellular PP including a high-voltage module providing dc bias voltage up to 2 kV. This bias voltage led to an increase in the signal-to-noise ratio of up to 15 ± 1 dB. The measurement of the received signal depending on the applied bias voltage is proposed as a new method of determining the internal voltage of ferroelectrets. The sensor combined with a cellular PP transmitter was applied to nondestructive testing of a rotor blade segment and glued-laminated timber, enabling imaging of the internal structure of these specimens with a thickness around 4 cm.
The application of phased arrays in either linear or matrix arrangement in combination with signal processing opens the door for the mechanized inspection of different thin wall materials itself as well as their joining methods.
Modern lightweight components are typically manufactured by a composition of different types of e.g. steels, metals, fiber reinforced plastics and glass. Dependent on the material combinations e.g. welding, brazing, bonding, cladding or coating may be applied during the manufacturing process to join different semi-finished products to form the component.
The resulting complex material composition and different damage mechanisms pose new challenges to non-destructive testing with ultrasound due to the different material properties and the overall arrangement of the materials employed.
The sound field variation capabilities of array probes may be helpful to overcome some of these challenges if adapted to the specific inspection task.
Examples for the non-destructive mechanized phased array inspection of different types of materials and joining methods will be presented.
Commercially available air-coupled transducers applied in non-destructive testing consist of a piezocomposite material and matching layers to reduce the impedance mismatch between the transducer and air. This contribution is an overview of innovative approaches using new piezoelectric materials and other physical principles to transmit and receive an ultrasonic pulse in air. Capacitive and piezoelectric micromachined ultrasonic transducers (CMUTs and PMUTs) produce high pressure levels, but they exhibit a very narrow bandwidth. Optical laser-based methods for transmitting and receiving ultrasound promise a higher bandwidth, but do not achieve the same sensitivity as conventional air-coupled transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties, having a very small acoustic impedance well matched to air. Ferroelectret transducers achieve about the same bandwidth as the most broadband conventional air-coupled transducers, having a higher sensitivity. Thermoacoustic transducers use heat to initiate an acoustic wave, acting as transmitters in ultrasonic range. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. The newest member of the family of air-coupled ultrasonic transmitters is the plasma-based transducer, using both the thermoacoustic effect and the movements of the ions (so called ionic wind) to create acoustic waves.
The use of composite materials has been steadily growing during the last decades, as well as the requirements on quality, mechanical properties and geometries of the parts. Some processes, like the 3D UV pultrusion process, manufacture parts that are long and thin, whilst having a varying curvature radius along the same part or even no curvature at all. Studying their mechanical properties along the main fiber direction, which is of foremost interest, is not an easy task nor efficient with most nondestructive methods. The use of air-coupled ultrasonics to evaluate the properties of composite materials has been widely proved by several authors, mainly using guided waves that provide information on the orthotropic properties of this kind of materials. Most of this work has focused on analyzing straight plate-like geometries, due to the simplicity to generate desired Lamb modes in the plate and analyze the behavior of guided waves inside the plate. In our contribution, the differences in the propagation of Lamb waves for straight and curved geometry glass fiber reinforced polymers (GFRP) have been analyzed. A GFRP test sample cured with UV light with one straight and one curved area has been evaluated. The responses of the generated Lamb wave modes for the straight and curved geometries have been compared, accounting for variations in the transducer characteristics, e.g. resonance behavior and focusing.
Conventional ultrasonic testing involves the application of a fluid couplant for impedance matching. Increasing use of lightweight structures, composite materials and adhesive joints mostly in aerospace and automotive industry created an increasing interest in air-coupled ultrasonic testing methods, to protect sensitive surfaces and simplify maintenance. Commercially available air-coupled transducers consist of a piezocomposite material and matching layers to reduce the impedance mismatch between the transducer and air. This contribution is an overview of innovative approaches using new piezoelectric materials and other physical principles to transmit and receive an ultrasonic pulse in air.
Capacitive and piezoelectric micromachined ultrasonic transducers (CMUTs and PMUTs) produce high pressure levels, but they exhibit a very narrow bandwidth. Optical laser-based methods for transmitting and receiving ultrasound promise a higher bandwidth, but do not achieve the same sensitivity as conventional air-coupled transducers. Ferroelectrets are charged cellular polymers exhibiting piezoelectric properties, having a very small acoustic impedance well matched to air. Ferroelectret transducers achieve about the same bandwidth as the most broadband conventional air-coupled transducers, having a higher sensitivity. Thermoacoustic transducers use heat to initiate an acoustic wave, acting as transmitters in ultrasonic range. Thermoacoustic transducers enable excitation of extremely broadband pulses while producing high pressure levels, which opens new possibilities for advanced signal processing. The newest member of the family of air-coupled ultrasonic transmitters is the plasma-based transducer, using both the thermoacoustic effect and the movements of the ions (so called ionic wind) to create acoustic waves.