Analytische Chemie
Filtern
Erscheinungsjahr
- 2017 (193) (entfernen)
Dokumenttyp
- Posterpräsentation (193) (entfernen)
Sprache
- Englisch (169)
- Deutsch (23)
- Mehrsprachig (1)
Schlagworte
- Nanoparticles (14)
- Online NMR spectroscopy (10)
- XPS (9)
- CONSENS (8)
- In situ (7)
- LIBS (7)
- Nanoparticle (7)
- Fluorescence (6)
- Online NMR Spectroscopy (6)
- Process analytical technology (6)
Analysis of stable isotopes has been used as proof of provenance of mineral and biological samples, to estimate a contamination source and to determine geological processes. This kind of analysis needs high accuracy and precision for reliable conclusions. Currently, stable isotope analysis is dominated by mass spectrometric techniques that are time consuming and expensive. Here we present a fast and low cost alternative for isotope analysis of boron and magnesium: high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). Two stable isotope systems were evaluated separately: boron (10B:11B) and magnesium (24Mg:25Mg:26Mg). Their isotope amount ratios were estimated by monitoring their absorption spectra in-situ generated monohydrides. The molecular absorption spectrum of a XH molecule (X= B or Mg) with n isotopes would be a linear combination of n isotopologue spectra and the amount of each component (isotope) could be calculated by a multivariate regression (n= 2 and 3 for B and Mg respectively). For the analysis of boron certified reference materials (CRM), the band 1→1 for the electronic transition X1Σ+ → A1Π was measured around wavelength 437.1 nm. Since boron has a memory effect in graphite furnaces, a combination of 2 % (v/v) hydrogen gas in argon, 1 % trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers were used during the BH vaporization at 2600 °C. Partial least square regression (PLS) for analysis of samples was applied. For this, a spectral library with different isotope ratios for PLS regression was created. Magnesium does not have memory effect. Therefore, only 2 % of hydrogen in argon as gas modifier during vaporization at 2500 °C was employed for analysis of magnesium CRM. Absorption spectra of MgH for the X2Σ→A2Π electronic transition (band 0→0) were recorded around wavelength 513.45 nm. A similar PLS procedure to the BH was applied. Results for B and Mg CRM are metrologically compatible with those reported by mass spectrometric methods. An accuracy of 0.08 ‰ for B and 0.1 ‰ Mg was obtained as the average deviation from the isotope CRM. Expanded uncertainties with a coverage factor of k = 2 range between 0.10 - 0.40 ‰.
Variations in the isotope amount composition of some elements like lithium, boron, magnesium, calcium, copper and strontium have been used as proof of provenance of a sample and to describe geological processes. Routinely, isotope compositions are determinate by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time consuming and they require a high qualified analysist.
Here an alternative faster and low cost optical method for isotope ratio determination is proposed: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X= Li, B, Mg, Ca, Cu and Sr have been determined by monitoring the absorption spectrum of their monohydride (XH) in graphite furnace HR-CS-MAS. For example, for the three Mg isotopes (24Mg, 25Mg and 26Mg) band (0→0) for the electronic transition X1Σ+ → A1Π was evaluated around wavelength 513.4 nm (Fig. 1). Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression were built. Results are metrological compatible with those reported by mass spectrometric methods.
Boron presents two stable isotopes, 10B and 11B and due to their relatively large mass difference (~ 10%) isotope fractionation leads to considerable isotope amount ratio variations n(10B)/n(11B) in natural occurrence. These have been used as a proof of provenance of mineral and biological samples, to estimate a contamination source and to the determination of geological processes by erosion or subduction. Additionally, boron is employed in the nuclear industry due to the capability of its isotope 10B to thermal-neutron capture and therefore 10B enriched boric acid solutions are used in the cooling system of thermonuclear facilities and in the alloying of steel and carbides for protective shielding. Usually, isotope ratio variations are determined by mass spectroscopic methods.
Here an alternative faster and low cost method for isotope ratio determination is proposed: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Boron isotope amount ratios have been determined by monitoring the absorption spectrum of boron monohydride (BH) in graphite furnace HR-CS-MAS. Bands (0→0) and (1→1) for the electronic transition X1Σ+ → A1Π were evaluated around wavelengths 433.1 nm and 437.1 nm respectively. Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression was built. Results obtained around the 433.1 nm and 437.1 nm spectral regions are metrologically compatible with those reported by mass spectrometric methods. Moreover, a precision and accuracy of the method of ± 0.5 ‰ for the evaluated spectral region around 437.1 nm is reported here. This accuracy and precision is comparable with those obtained by thermal ionization mass spectrometry (TIMS) and multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for boron isotope ratio measurements.
We developed a rapid and robust HPLC-MS/MS (QqQ) method for the quantification of hepcidin-25, a promising new biomarker in iron metabolism, in human samples. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyldimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no losses in the range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this liver produced peptide hormone plays a major role in the regulation of iron levels in mammals and can reveal important clinical information about several pathological states in patients suffering from iron-related disorders.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) to be implemented in routine laboratories. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyl-dimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no significant losses in the dynamic range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Careful analytical validation was performed for determining the reproducibility, repeatability, limit of quantification (0.5 µg/L) and linearity (0.5-40 µg/L) of the method. Serum samples from 9 healthy volunteers were analyzed with a median hepcidin-25 level of 3.3 µg/L, comparable to results reported in the literature.
HPLC-MS/MS quantification of hepcidin-25, a new promising iron biomarker, in human serum samples
(2017)
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this liver produced peptide hormone plays a major role in the regulation of iron levels in mammals. Hepcidin levels could reveal important clinical information about several pathological states in patients suffering from iron-related disorders such as chronic kidney disease (CKD) or hereditary haemochromatosis (HH). Despite significant efforts though, the development of a reliable assay to quantify hepcidin proved to be problematic for the last 15 years.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) to be implemented in routine laboratories. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyl-dimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no significant losses in the dynamic range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Careful analytical validation was performed for determining the reproducibility, repeatability, limit of quantification (0.5 µg/L) and linearity (0.5-40 µg/L) of the method. Serum samples from 9 healthy volunteers were analyzed with a median hepcidin-25 level of 3.3 µg/L, comparable to results reported in the literature.
The exploration of metal phosphonates chemistry has gained great interest during the last decades, because of their structural diversity. Transition metal phosphonates are promising candidates for an application as electrocatalysts in oxygen reduction reactions (ORR). Here, we present the in situ investigation of mechanochemical syntheses of two different manganese phosphonates by synchrotron X-ray diffraction. Nitrilotri(methylenephosphonic acid) and N,N-Bis(phosphonomethyl)glycine were chosen as ligands. The liquid-assisted milling process can be divided into three steps, including an amorphous stage. One of the products has not been obtained by classical solution chemistry before.
These metal phosphonates and/or their derivatives are considered to be active in electrochemical energy conversion. The verification of their applicability is one of the topics of our resent research.
Functional polymer based on 2,6-diaminopyridine with tunable UCST behaviour in water/alcohol mixture
(2017)
Thermoresponsive polymers are of great importance in numerous applications such as bioseparation, drug delivery, diagnostic and microfluidic applications.[1-2] Only a few thermoresponsive polymers have been reported that present an Upper Critical Solution Temperature (UCST), i.e. phase separate from solution upon cooling, in a relevant temperature range and “green” solvents such as water or ethanol.[3] Indeed, polymers with UCST behavior below 60°C in alcohol or water/alcohol mixtures are extremely promising for the preparation of “smart” materials for sensing.
In this work, two novel functional polymers of based on a 2,6-diaminopyridine motif were synthesized by free-radical polymerization. Their UCST-type transition temperature is tunable by varying either their concentration in solution or the type of solvent. Insights into this phenomenon are investigated using turbidimetry and temperature dependent dynamic light scattering.
Fluorescent nanoparticles that “light up”/”dim down” by applying external stimuli are of particular interest in the fields of sensing, diagnostics, photonics, protective coatings and microfluidics. The current challenge for these materials is to combine for instance fluorescence and its response to a stimulus such as temperature in a precise manner. Here we present such a system based on a core/shell/shell architecture consisting of a silica core with a fluorescent layer and a thermoresponsive shell.
The silica core nanoparticles were first coated with a fluorescent shell using surface initiated reversible addition-fragmentation chain transfer (RAFT) polymerization. The fluorescent nanoparticles were then completely engulfed by a switchable protective coating made of thermoresponsive poly(N-isopropylacrylamide). The fluorescence of the nanoparticles could be “switched on” at room temperature and “switched off” with increasing environmental temperature because of the presence of the thermoresponsive layer. Insights into this phenomenon will be given based on temperature dependent fluorescence measurements and dynamic light scattering.
Temperature switches “on” and “off” nanoparticle fluorescence in a core/shell/shell architecture
(2017)
Fluorescent nanoparticles that light “on/off” by applying external stimuli are of particular interest in the fields of sensing, diagnostics, photonics, protective coatings and microfluidics. The current challenge for these materials is for instance to combine fluorescence and its response to a stimulus such as temperature in a precise manner. Here we present such a system based on a core/shell/shell architecture consisting of a silica core with a fluorescent layer and a thermoresponsive shell.
In this work the silica core nanoparticles were first coated with a fluorescent shell using surface initiated reversible addition-fragmentation chain transfer (RAFT) polymerization. The fluorescent nanoparticles were then completely engulfed by a switchable protective coating made of thermoresponsive poly(N-isopropylacrylamide). The fluorescence of the nanoparticles could be “switched on” at room temperature and “switched off” with increasing environmental temperature because of the presence of the thermoresponsive layer. Insights into this phenomenon will be given based on temperature dependent fluorescence measurements and dynamic light scattering.