Analytische Chemie
Filtern
Erscheinungsjahr
- 2020 (503) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (246)
- Vortrag (140)
- Posterpräsentation (44)
- Beitrag zu einem Tagungsband (19)
- Sonstiges (16)
- Beitrag zu einem Sammelband (11)
- Forschungsdatensatz (7)
- Forschungsbericht (6)
- Dissertation (4)
- Handbuch (4)
- Buchkapitel (2)
- Corrigendum (2)
- Sammelband (Herausgeberschaft für den kompletten Band) (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (428)
- Deutsch (68)
- Mehrsprachig (3)
- Spanisch (2)
- Italienisch (1)
- Polnisch (1)
Schlagworte
- Nanoparticles (39)
- Fluorescence (24)
- Electron microscopy (13)
- Quantum yield (12)
- Sensor (12)
- Dye (11)
- Lifetime (11)
- Machine learning (11)
- Nano (11)
- BAMline (10)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (186)
- 6 Materialchemie (176)
- 8 Zerstörungsfreie Prüfung (112)
- 6.1 Oberflächen- und Dünnschichtanalyse (70)
- 6.3 Strukturanalytik (59)
- 8.0 Abteilungsleitung und andere (44)
- 1.2 Biophotonik (39)
- 1.1 Anorganische Spurenanalytik (35)
- 1.4 Prozessanalytik (34)
- 1.9 Chemische und optische Sensorik (34)
Paper des Monats
- ja (7)
Eingeladener Vortrag
- nein (140)
In 2019 over 30 000 people were killed or injured by explosions caused by explosives like TNT, PETN, HMX and RDX. Therefore, highly sensitive assays for the detection of TNT are needed. In this study we compared two commercially available TNT antibodies: A1.1.1 and EW75C with a highly optimized indirect competitive ELISA based on a BSA-TNA conjugate. As a result, a precision profile for both antibodies was determined with a LOD of 170 pmol L-1 for the clone A1.1.1 and a LOD of 3,2 nmol L-1 for the clone EW75C. The measurements showed that the clone A1.1.1 is a highly sensitive antibody for the detection of TNT while the clone EW75C does show medium performance at most.
In the cross-reactivity characterization of both antibodies many substances, closely related to the structure of TNT were tested. Both antibodies showed strong cross reactivity with trinitroaniline and trinitrobenzene. For the clone A1.1.1, which is known to originate from immunization of mice with an TNP-glycine-KLH conjugate, this has to be expected. Interestingly the clone EW75C, which was not characterized yet, showed similar behavior. This suggests a TNA-conjugate as immunogen for the EW75C antibody as well. None of both antibodies showed cross-reactions to the high explosives PETN, HMX and RDX. Also, the cross-reactions of nitro musks with the antibodies were investigated. Despite their prohibition, nitro musks are still used in Asia especially and are particularly popular in India. The overall superior clone A1.1.1 showed a significant cross-reactivity to musk ambrette. For practical reasons the influence of musk ambrette on this assay when used in natural environment should be investigated.
In further experiments, the highly sensitive TNT antibody A1.1.1 was digested with papain to obtain monovalent Fab-fragments. Due to its high stability against the digestion, a custom protocol for the IgG1 subclass of mice, to which the clone A1.1.1 belongs, was developed, resulting in a quantitative digestion of the intact antibody to Fab fragments. The success of the digestion was determined with MALDI-TOF-MS and SDS-PAGE. It was shown that this protocol worked for many different antibodies of IgG1 subclass as well.
In 2019 the Bundesanstalt für Materialforschung und –prüfung (BAM) conducted a benchmarking to compare the operations of European accreditation bodies and to identify best practices, with the aim of improving key processes in accreditation. Ten European accreditation bodies attended the comparison, four of which had already taken part in the pilot phase of the benchmarking project, which was conducted in 2017 by the German accreditation body Deutsche Akkreditierungsstelle GmbH (DAkkS) and BAM.
The study, designed to examine and compare the operation of accreditation bodies in Europe, used a management tool called Process Maturity Benchmarking Tool, which was especially elaborated and validated for this purpose in the pilot phase, in order to determine the values of indicators, thus enabling a comparison of the accreditation bodies despite different operational processes and organizational forms. The management tool is based on the analysis of selected processes with high relevance for the operation of accreditation bodies. The processes are derived from a process map designed for accreditation bodies in a universally applicable way. The indicators used to characterize the processes come from two sources: The first source relates to data already available from internal databases, reports, financial audits, and others. The second source is derived from the self-evaluation of process maturity performed by the accreditation bodies. The criteria for evaluating process maturities were designed by applying the criteria of the EFQM excellence model 2013 of the European Foundation for Quality Management (EFQM) to the processes identified in the process map.
The results of the analysis were presented to and discussed with representatives of the ten accreditation bodies at a Results-Workshop that took place at BAM on 21/22 January 2020.
This work presents a spectroscopic study of metallic pigments and metal foils used in reverse glass paintings that were created between 1912 and 1954. Metallic pigments induce a notable sparkling effect by means of the lateral incidence of light, whereas metal foils enhance the gloss and create a glittering effect when the painting is viewed in reflected light. Both effects were desired features especially in modern reverse paintings on glass and applied by artists in manifold creative manner. The paper gives an overview on the composition of the metalfoils and metal pigments in 14 works as determined in situ by X-ray spectrometry. Metal foils made of tin, brass, aluminium and silver were found in nine paintings. Gold imitating Cu-Zn pigments in different hues and with various Cu/Zn net intensity ratios were recorded for six paintings. Silvery pigments were identified mainly as Al pigments, but also as Cu-Zn-Ni alloy in one case. Other uncommon metallic pigments were detected in Arlequin vindicatif (c. 1925) by Floris Jespers, who used not only Cu-Zn and Al pigments, but also brownish Cu and Cu-Zn-Sn pigments. Non-invasive diffuse reflectance infrared Fourier-transform spectroscopy (DRIFTS) was used to classify the binding media of the metallic pigments. Drying oil and natural resin probably mixed with oil were the most common binding media. A polysaccharide-based binder was found in the silvery Cu-Zn-Ni pigment of Ohne Titel (1954) by Marianne Uhlenhuth.
Plant tissues are complex composite structures of organic and inorganic components whose function relies on molecular heterogeneity at the nanometer scale. Scattering-type near-field optical microscopy (s-SNOM) in the mid-infrared (IR) region is used here to collect IR nanospectra from both fixed and native plant samples. We compared structures of chemically extracted silica bodies (phytoliths) to silicified and nonsilicified cell walls prepared as a flat block of epoxy-embedded awns of wheat (Triticum turgidum), thin sections of native epidermis cells from sorghum (Sorghum bicolor) comprising silica phytoliths, and isolated cells from awns of oats (Avena sterilis). The correlation of the scanning-probe IR images and the mechanical phase image enables a combined probing of mechanical material properties together with the chemical composition and structure of both the cell walls and the phytolith structures. The data reveal a structural heterogeneity of the different silica bodies in situ, as well as different compositions and crystallinities of cell wall components. In conclusion, IR nanospectroscopy is suggested as an ideal tool for studies of native plant materials of varied origins and preparations and could be applied to other inorganic–organic hybrid materials.
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration.
Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet Setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet Generator (μDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of μDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running.
Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle.
While mode I (counting) and mode III (μDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic Standard solutions only. It is independent of NP reference materials. The μDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.
Abdominal aortic aneurysm (AAA) remains a fatal disease. Its development encompasses a complex interplay between hemodynamic stimuli on and changes in the arterial wall. Currently available biomarkers fail to predict the risk of AAA rupture independent of aneurysm size. Therefore, novel biomarkers for AAA characterization are needed. In this study, we used a mouse model of AAA to investigate the potential of magnetic resonance imaging (MRI) with an albumin-binding probe to assess changes in vascular permeability at different stages of aneurysm growth. Two imaging studies were performed: a longitudinal study with follow-up and death as endpoint to predict rupture risk and a week-by-week study to characterize AAA development. AAAs, which eventually ruptured, demonstrated a significantly higher in vivo MR signal enhancement from the albumin-binding probe (p = 0.047) and a smaller non-enhancing thrombus area compared to intact AAAs (p = 0.001). The ratio of albumin-binding-probe enhancement of the aneurysm wall to size of non-enhancing-thrombus-area predicted AAA rupture with high sensitivity/specificity (100%/86%). More advanced aneurysms with higher vascular permeability demonstrated an increased uptake of the albumin-binding-probe. These results indicate that MRI with an albumin-binding probe may enable noninvasive assessment of vascular permeability in murine AAAs and prediction of rupture risk.
The scribe of ‘Erfurt 7’, a thirteenth-century Torah scroll now kept in Berlin, initially left blank spaces for the divine appellations Elohim ( אלהים ) and YHWH Elohim ( ,(יהוה אלהים which were filled in during a second stage of writing. The appearance of the ink employed to write the appellations was significantly darker than that of the surrounding ink.
X-ray fluorescence analysis (XRF) has shown that the light and dark brown inks had similar elemental compositions, but contained different ratios of iron to potassium, which could be explained by the use of different batches of ink.
According to some medieval sources, the divine appellations were sometimes filled in during a second stage of writing in the presence of ten men from the Jewish community. In Erfurt 7, the two-stage procedure was only performed in the first 1.5 columns of the original sheets, suggesting it may have been part of a public ceremony inaugurating the writing of the divine names in the scroll. Erfurt 7 emerges from this study not only as a ritual object used for liturgy, but as a rallying point for the Jews of Erfurt to come together as a community to express their reverence for the written form of God’s name. The divine name YHWH ( יהוה ) was written in a smaller script than the surrounding text on three replacement sheets using the same two-stage procedure. The ink used on the replacement sheets contained zinc, which is characteristic of other Erfurt manuscripts as well. This suggests that Erfurt was the place where the scroll was used, cherished and eventually repaired.
The evaluation of measurement uncertainty is essential for testing and calibration laboratories. This paper provides a general process description for the determination of the measurement uncertainty of quantitative data and its application to the conformity assessment with examples, and how to deal with the uncertainty of qualitative (Boolean) results, e. g. when "Alarm" or "No alarm" occours in an instrument display.