In civil engineering concrete is the most used building material for making infrastructures like bridges and parking decks worldwide. It is as a porous and multiphase material made of aggregates with a defined grain size distribution, cement and water as well as different additives and admixtures depending on the application. Different grain sizes are important to ensure the needed density and compressive strength.
The resulting porous cement matrix contains a mixture of flour grains (aggregates with a grain size below 125 lm) and cement particles (particle size≈50lm). Harmful species like chlorides may penetrate together with water through the capillary pore space and may trigger different damage processes. The damage assessment of concrete structures in Germany is estimated due to the quantification of harmful elements regarding to the cement content only. In the evaluation of concrete using LIBS a two-dimensional scanning is necessary to consider the heterogeneity caused by the aggregates. Therefore, a LIBS system operating with a low energy NdCr:YAG laser, a pulse energy of 3 mJ, a wavelength of 1064 nm, a pulse width of 1.5 ns and a Repetition rate of 100 Hz has been used. Different Czerny-Turner spectrometers with CCD detectors in the UV and NIR range have been used for the detection. Large aggregates (macro-heterogeneity) can be excluded from the evaluation, whereas small aggregates in the range of the laser spot size (flour grains) cannot be spatially resolved. In this work the micro heterogeneity caused by flour grains and their impact on the quantification with LIBS will be discussed. To analyze the effect of changing grain sizes and ratios, the ablation behavior has been determined and compared. Samples with defined grain sizes were made and analyzed using LIBS.
The grain size distributions were analyzed with laser diffraction (LDA).
Accuracy of calibration-free (CF) methods in laser-induced breakdown spectroscopy (LIBS) depends on experimental conditions and instrumental parameters that must match a CF LIBS model. Here, the numerical study is performed to investigate effects of various factors, such as the optical density, plasma uniformity, line overlap, noise, spectral resolution, electron density and path length on the results of CF-LIBS analyses. The effects are examined one-by-one using synthetic spectra of steel slag samples that fully comply with the mathematical model of the method. Also, the algorithm includes several new features in comparison with previously proposed CF algorithms. In particular, it removes limits on the optical thickness of spectral lines that are used for the construction of the Saha-Boltzmann plot; it retrieves the absorption path length (Plasma diameter) directly from spectral lines; it uses the more realistic Voigt line profile function instead of the Lorentzian function; and it employs the pre-calculated and tabulated thin-to-thick line ratios instead of approximating functions for selfabsorption correction.
Analyse des Tausalzeintrages in Fahrbahndeckenbetone im Kontext der Alkali-Kieselsäure-Reaktion
(2018)
In den letzten Jahren sind im deutschen Bundesautobahnnetz (BAB-Netz) vermehrt AKR-Schäden an Betonfahrbahndecken aufgetreten, die zum Teil zu einer Halbierung ihrer geplanten Nutzungsdauer von 30 Jahren führte. Ursächlich hierfür ist die Verwendung alkaliempfindlicher Gesteinskörnung, die bei gleichzeitiger Anwesenheit von Wasser infolge der Exposition der Fahrbahndecke und dem alkalischen Milieu durch den Einsatz alkalireicher Portlandzemente bei der Betonherstellung zu einer Alkali-Kieselsäure-Reaktion (AKR) führt. Zusätzlich wird der AKR-Schädigungsprozess in Betonfahrbahndecken durch den externen Tausalzeintrag (primär NaCl) im Winter begünstigt. Vor diesem Hintergrund kommt der Ermittlung des Tausalzeintrags in den Fahrbahndeckenbeton eine große Bedeutung zu. Die Analyse des Tausalzeintrags erfolgte bisher ausschließlich nasschemisch an gemahlenen Bohrkernsegmenten. Nachteilig ist hierbei die fehlende differenzierte Betrachtung des Natriumgehaltes im Zementstein und in der Gesteinskörnung. Der alternative Einsatz von LIBS (Laser-induced breakdown spectroscopy) eröffnet in diesem Kontext neue Möglichkeiten. So wird in diesem Beitrag an Hand von Bohrkernen aus einem AKR-geschädigten BAB-Abschnitt exemplarisch die Vorgehensweise bei der LIBS-Analyse zur Ermittlung der Na- und interagierenden Cl-Verteilung an vertikalen Schnittflächen des Bohrkerns aufgezeigt. Da der Tausalzeintrag primär über den Zementstein erfolgt, wurde der verfälschende Na-Grundgehalt der Gesteinskörnung mittels Zementsteinkriteriums (Nutzung unterschiedlichen Ca-Gehalts in Zementstein und Gesteinskörnung) eliminiert. Vergleichend durchgeführte Cl-Mappings mit Mikroröntgenfluoreszenzanalyse (MRFA) belegen die Güte der durchgeführten LIBS-Messungen.
Aber auch bei der Verifizierung der Übertragbarkeit der Ergebnisse der zum Ausschluss reaktiver Gesteinskörnung bei Neubau und Erneuerung im BAB-Netz eingesetzten Performanceprüfungen mit externem Alkalieintrag auf Praxisverhältnisse hat sich das LIBSVerfahren bewährt. So wurde festgestellt, dass die mit NaCl-Lösung beaufschlagten Laborprüfkörper aus einem repräsentativen Fahrbahndeckenbeton bei der Klimawechsellagerung (KWL) über ihre gesamte Höhe von 10 cm einen Eintrag von Na und Cl erfahren. Weiterhin konnte im Gegensatz zu bisherigen Annahmen erstmals mit LIBS und Nasschemie gezeigt werden, dass die Frost-Tauwechsel-Phase bei der KWL zu keinem erhöhten Tausalzeintrag führt.
The determination of chloride is still one of the main tasks for the evaluation of reinforced concrete structures.
The corrosion of the reinforcement induced by the penetrating chlorides is the dominant damage process affecting the lifetime of concrete structures. In the recent years different research groups demonstrated that LIBS can be a fast and reliable method to quantify chlorine in cement-bound materials. Because chlorine in concrete can only occur as solved ions in the pore solution or bound in salts or hydrated cement phases, the detected emission of chlorine can be correlated with the chloride concentration determined e.g. with potentiometric titration. This work inter alia describes the production of reference samples and possible side effects during the production process. Due to transport processes in the porous matrix of the cement a misinterpretation of the concentrations is possible. It is shown how to overcome these effects and higher precisions of the single measurements can be realised. Using the calibration method, blank sample method and noise method, three different ways of calculating the limit of detection (LOD) and limit of quantification (LOQ) are compared. Due to the preparation of the reference samples a precision of the whole calibration model of sx0 = 0.023 wt% is determined.
The validation of the model is based on different test sets, which are varying in their composition
(different Cl-salts, water-to-cement ratios and additives). The determined mean error of the validation is
0.595 ± 0.063 wt%, which is comparable to standardised methods like potentiometric titration, direct potentiometry
or photometry (0.40 ± 0.06 wt%) [1].
This paper will address the relevance of chloride measurements in practice for durability condition assessment and a description of the working principle of LIBS will be given. Examples of chloride profiles obtained by the common wet chemical analysis will be shown and compared with results from LIBS measurements as to demonstrate the accuracy of the LIBS-technique. The latter will be supported by clear graphs. In addition examples on the extra information resulting from measurements performed with LIBS for improvement of condition assessment and prediction will be shown.
The relevance of chloride measurements in practice for durability condition assessment and a description of the working principle of LIBS will be given. A comparison of chloride profiles obtained by the common wet chemical analysis and results from LIBS measurements are shown to demonstrate the accuracy of the LIBS-technique. In addition, an example on the extra information resulting from measurements performed with LIBS for improvement of condition assessment and prediction will be shown.
Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation.
BAM has developed the LIBS technique for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete. The possibility of automated measurements saves a lot of manpower and time. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods.
Typical results of 2D investigation of concrete in laboratory will be presented. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well.
Die „Laser Induced Breakdown Spectroscopy“ (LIBS) bietet die Möglichkeit, direkt auf der optisch zugänglichen Oberfläche von Baustoffen 2-dimensional die Elementverteilung zu erfassen. Durch das zugrundeliegende Prinzip sind alle Elemente des Periodensystems detektierbar, auch leichte Elemente wie Wasserstoff oder Lithium.
Einerseits können alle für die Zusammensetzung des Zementes und der Gesteinskörnung relevanten Elemente erfasst werden, andererseits auch die für Schädigungsprozesse in Beton wichtigen Elemente Chlor, Schwefel, Natrium, Kalium, Kohlenstoff und Stickstoff. Der Nachweis kann simultan erfolgen.
Der Vorteil des Verfahrens liegt in der einfachen Probenvorbereitung, der direkten Messung auf der Oberfläche des Festkörpers und der Schnelligkeit der Messung. Die Heterogenität von Beton wird im Ergebnis berücksichtigt. Die Konzentrationen von schädigenden Ionen lassen sich bezogen auf den Bindemittelgehalt angeben. LIBS liefert standardmäßig qualitative Werte. Durch Kalibrierung anhand von Referenzproben ist eine Quantifizierung der Ergebnisse möglich.
Das Potenzial des Verfahrens wird am Beispiel der Bestimmung der Chlorid-Verteilung in der Bindemittelmatrix vorgestellt. Andere Anwendungen sind die Bestimmung der Karbonatisierungstiefe, die Bestimmung des Eintrages von Alkalien oder die Bestimmung der Verteilung von Schwefel.
Das Verfahren kann im Labor zur Untersuchung einer großen Anzahl von Proben oder vor-Ort zur schnellen Entscheidungsfindung eingesetzt werden. Kommerzielle Geräte sind seit kurzem verfügbar.
Die örtliche Auflösung der Messung beträgt bis zu 0,1 mm × 0,1 mm. Ein Messpunkt hat einen Durchmesser von ca. 100 μm. Die Messfrequenz liegt bei 100 Hz. Als Ergebnis entstehen für jedes Element eine 2D-Darstellungen der Konzentration über der Messfläche.
Der Scan eines Bohrkerns von 50 mm x 70 mm dauert bei einer Auflösung von 0,5 mm lateral und 1 mm vertikal ca. 7 min. Es können auch raue oder gebrochene Oberflächen durch Nachführung der z-Achse untersucht werden. Die Nachweisgrenze für die Bestimmung des Chlorgehaltes bezogen auf den Bindemittelgehalt liegt bei 0,03 M-%.
Der Unterausschuss LIBS im Bauwesen im FA ZfP im Bauwesen der DGZfP arbeitet an der Erstellung von Merkblättern und Regelwerken zur Anwendung des Verfahrens.