The majority of the built infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores (every year nearly 4 billion tons of cement are produced which is largest mass flow generated by mankind). Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation.
For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures.
BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete [1-11]. The technique is established for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of manpower and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engineering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods.
Ingress of chlorides due to a crack in a repair mortar. Left: Photo of the cross section of a concrete core and the surface investigated by LIBS (area 70 mm x 70 mm). Right: Color coded chlorine intensity on the cross section of a concrete core, dark red represents high chlorine content.
The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well.
Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation.
BAM has developed the LIBS technique for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete. The possibility of automated measurements saves a lot of manpower and time. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods.
Typical results of 2D investigation of concrete in laboratory will be presented. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well.
The application of a LIBS system is presented. A diode-pumped low energy laser (3 mJ, 1.5 ns, 100 Hz) and a compact NIR spectrometer are used. A scanner allows the two-dimensional element mapping. For the quantitative analysis calibration of the system is carried out with reference samples in a concentration range of chlorine of 0.05 wt.% to 2.5 wt.%. To determine the 2D distribution of harmful elements (Cl, C), concrete cores were drilled, split and analyzed directly. By comparing the chloride ingress and the carbonation, the interaction of both processes can be visualized in one measurement that takes less than 10 minutes with a drill core of 50 mm x 100 mm. Results obtained were compared and verified with standard measurements.
Es wird ein alternatives Verfahren zur schnellen zweidimensionalen Analyse der chemischen Zusammensetzung von Baustoffen vorgestellt. Dieses beruht auf der Kombination des Abtrags einer geringen Materialmenge durch einen gepulsten Laser, der Plasmaerzeugung und der Analyse der Lichtemission des Plasmas mittels optischer Spektroskopie. Es können prinzipiell alle Elemente gleichzeitig nachgewiesen werden. Damit ist es möglich einerseits Informationen über den Baustoff an sich als auch über den Eintrag potentiell schädigender Elemente (z. B. Cl, C, Na, K, S) zu gewinnen. Das Verfahren kann automatisiert im Labor oder als mobile Version direkt vor Ort eingesetzt werden. Es liefert zweidimensionale Bilder der Elementverteilung in Echtzeit. Es kann ohne große Probenvorbereitung z. B. direkt an der Querschnittsfläche eines Bohrkernes gemessen werden. Die Messung dauert nur wenige Minuten. Das Prinzip der Messung, die Vor- und die Nachteile, sowie die verfügbare Gerätetechnik für den Einsatz im Labor oder direkt am Bauwerk werden vorgestellt. Abschließend werden praktische Beispiele für die Anwendung des LIBS-Verfahrens zur Erfassung des Chlorid-Eintrages, der Karbonatisierung und der Verteilung von Schwefel präsentiert.
Im Zuge der Ist-Zustandserfassung von Stahl- und Spannbetonbauwerken spielt die chemische Analyse von Beton eine zentrale Rolle. Durch den externen Eintrag von schädigenden Substanzen wie Chlorid oder Alkalien aus Tausalzen oder Meerwasser, kann u.U. der Beton und/oder die Stahlbewehrung angegriffen werden. Bei Überschreitung kritischer korrosionsauslösender Chloridgehalte, z.B. bei Stahlbeton 0,4 M.-% (bzw. 0,5 M.-%) und Spannbeton 0,2 M.-% bezogen auf den Zement, erhöht sich das Risiko für eine Chlorid-induzierte Korrosion. Für die Beurteilung eines Instandsetzungsbedarfs und, sofern notwendig, der Erarbeitung eines Instandsetzungskonzeptes muss nach der Rili-SIB1 ein sachkundiger Planer herangezogen werden. Standardmäßig werden für die chemische Analyse Bohrkerne bzw. Bohrmehlproben aus dem zu untersuchenden Bauwerk entnommen und nach aufwendiger Probenvorbereitung nasschemisch analysiert (nach DAfStb Heft 401 oder DIN 14629). Dabei wird der Gesamtchloridgehalt bezogen auf die Einwaage angegeben. Eine Umrechnung auf den Zementgehalt erfolgt i.d.R. durch Schätzwerte. Der Einsatz der laserinduzierten Plasmaspektroskopie (LIBS) wird seit Mitte der 90er Jahren an der Bundesanstalt für Materialforschung und -prüfung erforscht, um den Chloridgehalt durch eine ortsaufgelöste Elementanalyse an einer Betonprobe möglichst genau zu ermitteln. Die zweidimensionale LIBS-Messung mit einer lateralen Auflösung von 100 µm x 100 µm erlaubt die Berücksichtigung der Heterogenität von Beton. Dabei lassen sich die Bindemittelmatrix und die Gesteinskörnung separat betrachten, wodurch sich die Aussagekraft der Ergebnisse und somit die Sicherheit der chemischen Zustandserfassung erhöht. Durch die stetige Weiterentwicklung von Komponenten wie Laser, Spektrometer und analytischer Auswerteroutinen sind mittlerweile automatisierte Systeme für die schnelle LIBS-Analyse auf dem Markt verfügbar. In diesem Vortrag wird der aktuelle Stand der Technik anhand von Praxisbeispielen präsentiert und entscheidende Vorteile gegenüber dem Standardverfahren herausgestellt. Aufgrund der Möglichkeit für eine simultane Multielementanalyse mit LIBS werden weitere Anwendungen, wie z.B. die Ermittlung der Karbonatisierungstiefe, Untersuchungen von Transportprozessen, Chlorideintrag entlang von Rissen oder Untersuchungen von Elementverteilungen im Kontext einer AKR vorgestellt.