Analytische Chemie
Filtern
Erscheinungsjahr
- 2021 (14) (entfernen)
Dokumenttyp
- Vortrag (7)
- Zeitschriftenartikel (5)
- Video (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (14)
Schlagworte
- X-ray scattering (10)
- MOUSE (7)
- SAXS (7)
- Methodology (6)
- Instrumentation (5)
- Automation (2)
- Data organization (2)
- Nanostructure (2)
- Traceability (2)
- USAXS (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (7)
This is a set of drawings accompanying the submitted paper entitled "Extending Synchrotron SAXS instrument ranges through addition of a portable, inexpensive USAXS module with vertical rotation axes". The parts described herein will combine with commercial off-the-shelf components to build a high precision pair of rotation stages for accurate measurement of scattering angles with a sub-microradian precision.
Compared to the clear, real-space images you can get from electron microscopy, X-ray scattering patterns are rather featureless. These patterns, however, contain structural information from all of the material structure illuminated by the X-ray beam. With this technique, you can measure nanoparticle dispersions, catalysts, composites, MOF powders, battery materials, light metal alloys and gels to reveal information on the structural features found within these materials. We have even measured many such materials for several research groups from the University of Birmingham, revealing structure features in the sub-nm to the micrometer range.
Measuring an X-ray scattering pattern is relatively easy, but measuring a high-quality, useful pattern requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration) [1]. With the MOUSE, we have combined: a) a comprehensive and highly automated laboratory workflow with b) a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data.
Introduction
A good laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). In the MOUSE, we have combined: a) a comprehensive laboratory workflow with b) a heavily modified, highly automated X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, with a well-documented data flow (akin to what is found at the more automated beamlines). With two full-time researchers, the lab collects and interprets thousands of datasets, on hundreds of samples for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data.
While these numbers do not light a candle to those achieved by our hardworking compatriots at the synchrotron beamlines, the laboratory approach does allow us to continually modify and fine-tune the integral methodology. So for the last three years, we have incorporated e.g. FAIR principles, traceability, automated processing, data curation strategies, as well as a host of good scattering practices into the MOUSE system. We have concomitantly expanded our purview as specialists to include an increased responsibility for the entire scattering aspect of the resultant publications. This ensures full exploitation of the data quality, whilst avoiding common pitfalls.
Talk scope
This talk will present the MOUSE project as implemented to date, and will introduce foreseeable upgrades and changes. These upgrades include better pre-experiment sample scattering predictions to filter projects on the basis of their suitability, exploitation of the measurement database for detecting long-term changes and automated flagging of datasets, extending the measurement range through an Ultra-SAXS module, and enhancing MC fitting with sample scattering simulations for better matching of odd-shaped scatterers.
The SAXS platform at BAM
(2021)
The Meticulous Approach: Fully traceable X-ray scattering data via a comprehensive lab methodology
(2021)
To find out if experimental findings are real, you need to be able to repeat them. For a long time, however, papers and datasets could not necessarily include sufficient details to accurately repeat experiments, leading to a reproducibility crisis. It is here, that the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration) tries to implement change – at least for small- and wide-angle X-ray scattering (SAXS/WAXS).
In the MOUSE project, we have combined: a) a comprehensive laboratory workflow with b) a heavily modified, highly automated Xenocs Xeuss 2.0 instrumental component. This combination allows us to collect fully traceable scattering data, with a well-documented data flow (akin to what is found at the more automated beamlines). With two full-time researchers, the lab collects and interprets thousands of datasets, on hundreds of samples for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data.
While these numbers do not light a candle to those achieved by our hardworking compatriots at the synchrotron beamlines, the laboratory approach does allow us to continually modify and fine-tune the integral methodology. So for the last three years, we have incorporated e.g. FAIR principles, traceability, automated processing, data curation strategies, as well as a host of good scattering practices into the MOUSE system. We have concomitantly expanded our purview as specialists to include an increased responsibility for the entire scattering aspect of the resultant publications, to ensure full exploitation of the data quality, whilst avoiding common pitfalls.
This talk will discuss the MOUSE project1 as implemented to date, and will introduce foreseeable upgrades and changes. These upgrades include better pre-experiment sample scattering predictions to filter projects on the basis of their suitability, exploitation of the measurement database for detecting long-term changes and automated flagging of datasets, and enhancing MC fitting with sample scattering simulations for better matching of odd-shaped scatterers.
The Dark side of Science
(2021)
We all may have started out as bright-eyed students trying to do science to the best of our abilities, but over time, some of us have gradually drifted to the dark side. The dark side of science has an impressive publication rate in high-ranking journals, good success with funding agencies, and rocks the world with stellar findings. Unfortunately, these findings aren't real, either by accident or on purpose. As the presenter and his colleagues found, trying to correct or even dispute any of these findings in literature is a supremely complex and time-consuming effort.
With no recent reduction in the frequency of such false findings, it is up to us to try to stem the flow. Besides looking at examples, we need to understand the underlying driving forces behind this dark scientific movement. By combining this understanding with a refresher of the core scientific principles, we can then develop the necessary argumentative tools and mechanisms that may prevent our own slide down the slippery slope.
This talk will therefore start out with several entertaining examples of probably accidental, as well as definitely deliberate, false scientific findings in literature (and in particular in the field of materials research). We will then take a brief look at the possible causes for these developments, after which some tools will be presented that can help both the fresh as well as the well-seasoned scientist to rise up against the dark side.
Today's speaker is a young scientist whose research on all aspects of small-angle scattering has taken him from his birthplace in Netherlands, to Denmark, Japan and now Germany. His research has led to a new method and software for scattering pattern analysis, a comprehensive set of data corrections together with the Diamond Light Source, and a new ultra-SAXS plug-in instrument.
For the last few years, he has been working on a comprehensive and universal methodology to get high-quality X-ray scattering measurements for any sample, using his new instrument at the institute. This instrument has now been heavily modified both in hardware and software, so that it can deliver better data.
These developments are always driven by interesting collaborations with materials researchers and other scientists. As a joint member he has published works on a wide variety of materials, including self-assembled structures in liquids, composite materials and porous carbon catalysts.
He has also been very active in outreach, for example by co-organizing an online lecture series called ‘#the Light Stuff’ on scattering and diffraction, running the ‘looking at nothing’ weblog, hosting a yearly introductory scattering course, and he has many scattering-related lectures available on YouTube.
Our distinguished speaker is Dr. Brian Richard Pauw from the Federal Institute for Materials Research and Testing in Germany. I proudly invite Dr. Pauw to begin his talk
Today's speaker is a young scientist whose research on all aspects of small-angle scattering has taken him from his birthplace in Netherlands, to Denmark, Japan and now Germany. His research has led to a new method and software for scattering pattern analysis, a comprehensive set of data corrections together with the Diamond Light Source, and a new ultra-SAXS plug-in instrument.
For the last few years, he has been working on a comprehensive and universal methodology to get high-quality X-ray scattering measurements for any sample, using his new instrument at the institute. This instrument has now been heavily modified both in hardware and software, so that it can deliver better data.
These developments are always driven by interesting collaborations with materials researchers and other scientists. As a joint member he has published works on a wide variety of materials, including self-assembled structures in liquids, composite materials and porous carbon catalysts.
He has also been very active in outreach, for example by co-organizing an online lecture series called ‘#the Light Stuff’ on scattering and diffraction, running the ‘looking at nothing’ weblog, hosting a yearly introductory scattering course, and he has many scattering-related lectures available on YouTube.
Our distinguished speaker is Dr. Brian Richard Pauw from the Federal Institute for Materials Research and Testing in Germany. I proudly invite Dr. Pauw to begin his talk.
Ultra-SAXS can enhance the capabilities of existing synchrotron SAXS/WAXS beamlines. A compact ultra-SAXS module has been developed, which extends the measurable q-range with 0.0015 ≤ q (nm−1) ≤ 0.2, allowing structural dimensions in the range 30 ≤ D (nm) ≤ 4000 to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the module components in and out on their respective motor stages, SAXS/WAXS measurements can be easily and rapidly interleaved with USAXS measurements. The use of vertical crystal rotation axes (horizontal diffraction) greatly simplifies the construction, at minimal cost to efficiency. In this paper, the design considerations, realization and synchrotron findings are presented. Measurements of silica spheres, an alumina membrane, and a porous carbon catalyst are provided as application examples.