Analytische Chemie
Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (114)
- Deutsch (1)
- Mehrsprachig (1)
Referierte Publikation
- nein (116) (entfernen)
Schlagworte
- Fluorescence (116) (entfernen)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (74)
- 1.2 Biophotonik (48)
- 1.9 Chemische und optische Sensorik (21)
- 6 Materialchemie (6)
- 1.5 Proteinanalytik (4)
- 6.3 Strukturanalytik (4)
- 1.1 Anorganische Spurenanalytik (3)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 8 Zerstörungsfreie Prüfung (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
Eingeladener Vortrag
- nein (64)
We developed a new method for full field X-ray fluorescence imaging at the BAMline @ BESSY II. We combined an energy dispersive array detector for X-rays with a coded aperture to get high resolution images.
In coded aperture imaging, an object is projected through a mask, producing many overlapping images on the detector. To get the information about the investigated object out of the projected image, a decoding step is necessary.
The first part of our project was to develop the decoding algorithms. We tested the reported reconstruction with an antimask and compared the results with the performance of self-written reconstruction programs based on an iterative and a genetic algorithm. First tests were performed with raytracing simulations.
The next step was the collection of experimental data at the BAMline @ BESSY II (HZB). A test objects could be successfully reconstructed with our newly developed algorithm.
Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging . We combine an energy dispersive array detector with a coded aperture to obtain high resolution images . To obtain the information from the recorded image a reconstruction step is necessary . The reconstruction methods we have developed , were tested on simulated data and then applied to experimental data . The first tests were carried out at the BAM line @ BESSY II. This method enables the simultaneous detection of multiple elements , which is important e.g. in the field of catalysis.
Current trends in materials and life sciences are flanked by the need to push detection limits to single molecules or single cells, enable the characterization of increasingly complex matrices or sophisticated nanostructures, speed up the time of analysis, reduce instrument complexity and costs, and improve the reliability of data. This requires suitable analytical tools such as spectroscopic, separation and imaging techniques, mass spectrometry, and hyphenated techniques as well as sensors and their adaptation to application-specific challenges in the environmental, food, consumer product, health sector, nanotechnology, and bioanalysis. Increasing concerns about health threatening known or emerging pollutants in drinking water, consumer products, and food and about the safety of nanomaterials led to a new awareness of the importance of analytical sciences. Another important driver in this direction is the increasing demand by legislation, particularly in view of the 17 sustainable development goals by the United Nations addressing clean energy, industry, and innovation, sustainable cities, clean water, and responsible consumption and production. In this respect, also the development of analytical methods that enable the characterization of material flows in production processes and support recycling concepts of precious raw materials becomes more and more relevant. In the future, this will provide the basis for greener production in the chemical industry utilizing recycled or sustainable starting materials.
This makes analytical chemistry an essential player in terms of the circular economy helping to increase the sustainability of production processes. In the life sciences sector, products based on proteins, such as therapeutic and diagnostic antibodies, increase in importance. These increasingly biotechnologically produced functional biomolecules pose a high level of complexity of matrix and structural features that can be met only by highly advanced methods for separation, characterization, and detection. In addition, metrological traceability and target definition are still significant challenges for the future, particularly in the life sciences.
However, innovative reference materials as required for the health and food sector and the characterization of advanced materials can only be developed when suitable analytical protocols are available. The so-called reproducibility crisis in sciences underlines the importance of improved measures of quality control for all kinds of measurements and material characterization. This calls for thorough method validation concepts, suitable reference materials, and regular interlaboratory comparisons of measurements as well as better training of scientists in analytical sciences.
The important contribution of analytical sciences to these developments is highlighted by a broad collection of research papers, trend articles, and critical reviews from these different application fields. Special emphasis is dedicated to often-overlooked quality assurance and reference materials.
Time-resolved flow cytometry
(2019)
The fast identification of a large number of analytes or events is increasingly required in bioanalytical, diagnostic, and security applications. The versatility and straightforward use make multiparametric fluorescence techniques particularly interesting as detection techniques. An established method for high-throughput single-cell and single-particle measurements is flow cytometry (FCM). Using only spectral encoding without further intensity information, state-of-the-art instruments equipped with several light sources and detectors can resolve almost 20 different color codes. However, this is not sufficient to answer complex research questions, e.g. in cell biology and immunology. In contrast, routine applications demand low-cost and sometimes even portable instruments and thus a minimum number of instrument components. Thus, there are currently two main research directions in FCM: the development of methods that can either address increasingly complex analytical challenges or provide low-cost and robust approaches for routine multiplex analyses. Common spectral multiplexing approaches face limitations in both directions. On the one hand, spectral overlap of labels restricts the number of codes and makes elaborate correction schemes necessary. On the other hand, even for lower degrees of multiplexing often a sophisticated optical setup is needed. An alternative to spectral multiplexing and intensity encoding is to exploit the luminescence lifetime (LT) as an encoding parameter. This can allow for extending the parameter space in combination with spectral encoding or result in more simple and compact devices due to fewer optical components. The availability of fast electronics enables miniaturized and portable lifetime measurement setups at relatively low cost. LT-FCM requires to master LT determination with a limited number of detected photons due to the short interaction time of the encoded objects with the laser spot. In this study, we address this issue for time-domain cytometry and present a novel lifetime flow cytometry (LT-FCM) platform based on a compact setup and straightforward time-domain measurements utilizing LT-encoded luminescent beads. Moreover, we present the realization of a first bioanalytical assay with LT-encoded beads.
Flow cytometry is a widely used method in biological research and medical diagnostics. Depending on the respective application, two opposing directions of development are currently of interest. On the one hand, there is a need for analyses of growing complexity employing more and more fluorescent labels and codes. On the other hand, cost-effective methods and portable, miniaturized, and robust instruments are desired.
Commonly performed spectral multiplexing utilizing a color code suffers from several problems, such as the sensitivity of fluorescence intensity measurements to fluctuations in excitation light intensity and dye concentration and hence, photobleaching, dye leaking for certain encoding procedures, and spectral crosstalk, limiting the achievable number of detection channels. Moreover, it typically requires several costly excitation light sources. An innovative alternative can be lifetime multiplexing and the discrimination between different encoding fluorophores and carrier beads based on their fluorescence decay kinetics. In order to examine the potential of this approach, dye encoded beads (lifetime encoded surface chemistry) were prepared using several fluorophores from different dye classes and their suitability for lifetime discrimination in a flow was tested in conjunction with a custom designed flow cytometer equipped with a pulsed light source and a fast detector.
In a first step, the spectroscopic properties of micrometer-sized dye-stained PMMA beads were studied by means of steady state and time-resolved photoluminescence measurements. For the performance of studies on the practical use of these microbeads in flow cytometry applications, a custom-built demonstrator model for a flow system was employed.
Our results demonstrated that lifetime discrimination and simultaneous readout of a ligand fluorescence signal for analyte quantification with a set of dye-stained polymer microbeads at single wavelength excitation is feasible. These studies are expected to pave the road for new applications of fluorescence lifetime multiplexing within the framework of time-domain flow cytometry and bead-based assays.
Integrating fluorescent probes with sensing matrices presents a major challenge because usually, when confined in a rather rigid matrix, fluorophores tend to behave completely different than for instance in the molecular state in solution. The lecture reviews the major strategies that have been devised recently to circumvent such issues with special focus on the works carried out in this field by BAM’s Chemical and Optical Sensing Division. Moreover, it will be shown that by using certain strategies not only can the response behavior be retained but synergistic effects can even endow the hybrid with a much better performance than the probe molecule alone.
Lanthanide-doped photon-upconversion nanoparticles (UCNPs) have been in the focus of many research activities in the material and life sciences over the last 15 years because of their potential to convert light between different spectral regions and their unique photophysical properties. In order to fully exploit the application potential of these fascinating nanomaterials, a number of challenges has to be overcome such as the low brightness particularly of small UCNPs and the reliable quantification of the excitation power density (P)-dependent upconversion luminescence (UCL). Here, the need and requirements on the characterization of the optical properties of UCNPs are discussed with special focus on the reliabiliy and comparability of relative and quantitative luminescence measurements and prerequisites for their standardization.
SWIR luminescent nanomaterials – key chemical parameters for bright probes for in vivo bioimaging
(2024)
A current challenge for studying physio-pathological phenomena and diseaserelated processes in living organisms with non-invasive optical bioimaging is the development of bright optical reporters that enable deep tissue penetration, a high detection sensitivity, and a high spatial and temporal resolution. The focus of this project are nanomaterials, which absorb and emit in the shortwave infrared (SWIR) between ~900–2500 nm where scattering, absorption, and autofluorescence of the tissue are strongly reduced compared to the visible and NIR.
Nowadays, superplasticizers (SPs) are widely used to increase fluidity and reduce water content in concrete; thus, allowing better workability for final applications. The present study will focus on the hydration effect using comb shape polycarboxylates (PCEs), which are known to allow a very low water/cement ratio (w/c of 0.20) or less.Optical methods have been successfully used for the analysis and monitoring of the interactions between a broad variety of nanoscale and molecular systems like nanoparticles of various chemical composition and different types of organic ligands or biomolecules.This encouraged us to assess the potential of these methods, and particularly fluorescence, for the investigation of the interactions that occur at the interface between hydrate surfaces of cement particles and PCE at a very early stage of concrete formation and to differentiate between the impact of PCE’s molecular structures on such interactions.
Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging, due to their many advantages like comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Drawbacks are , however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are time-dependent due to the aging of instrument components, and difficulties to measure absolute fluorescence intensities. Thus, there is a considerable need for standards for intensity, spectral, and temporal fluorescence quantities to meet the increasing need for instrument performance validation and global trends to harmonize physicochemical measurements. In this respect, instrument calibration strategies together with different types of fluorescence standards are presented as well as design concepts for robust, easy-to-use, and format-adaptable fluorescence standards useable for the determination of different fluorescence parameters and a broad variety of fluorescence techniques.