Additive Manufacturing provides an important enabling technology for the digital transformation of the economy. As an emerging technology it has seen a remarkable development over the last three decades. Nevertheless, it is far from a broad adoption with several barriers to overcome yet. One of the major challenges is the lack of standards. The critical role of standardization for innovation is generally recognized, still the topic too often has been neglected in strategic roadmapping exercises for emerging technologies. Too little is known about the complex dynamics and interrelations of standardization and innovation. The anticipation of standardization needs and the timely and efficient implementation of standards is challenging. This paper aims at contributing to a better understanding of the role that standards play in the multi-dimensional system of innovation. It analyzes the trajectories of innovation in Additive Manufacturing in a systematic and holistic way, focusing on standardization activities with regard to coordination, stakeholders involved, the timing and types of standards developed. Putting standardization in context of the multi-dimensional innovation system of Additive Manufacturing the research shows where standards can support the diffusion of an emerging technology.
Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
Bacterial biofilms represent a ubiquitous form of microbial life on Earth. Due to an evolved armory of protean biological responses to external stimuli, bacteria are able to adhere to, colonize and thrive on virtually all surfaces, whether natural or synthetic, even in challenging environmental conditions. In addition to significant health risks, biofilms are among the salient contributors to the deterioration of metals and their alloys, thereby causing safety risks for technical equipment. Hence, understanding the interaction mechanisms of electroactive sessile bacteria with metal surfaces is vital for facilitating the development of efficient control strategies and novel anti-fouling surfaces in various industries and technologies.
The present study focusses on a combined spectroelectrochemical approach, melding methods of surface enhanced Raman spectroscopy (SERS) and electrochemical techniques, to investigate the chemical characteristics and redox activities of electroactive bacteria during the initial stages of biofilm formation. Gold has been selected as a model substrate due to its inert character, considerably high surface enhancement factor, as well as its capability to allow surface chemistry modifications and substrate polarization in order to precisely control the surface charge. Square wave voltammetry (SWV) and cyclic voltammetry (CV) studies have been performed for quantitative determination of flavin concentration and electrochemical impedance spectroscopy (EIS) has been utilized to study the changes in electrochemical processes within biofilms during different stages of growth. Shewanella sp. have been chosen as microorganisms within this work due to their versatile exoelectrogenic respiratory behavior and their distinct ability to reduce metals via extracellular electron transfer mechanisms involving self-secreted electron shuttle redox molecules such as flavins. To further explicate the process of diffusion of flavins within biofilms, a model system has been developed to simulate the structural features of the bacterial extracellular polymeric substances typically found in biofilms. This has been achieved by creating hydrogel films comprised of calcium-cross-linked alginate. The results demonstrate an interplay of factors contributing to the initial phases of bacterial settlement and biofilm formation as a function of environmental parameters. Furthermore, the results allow insight into the diffusion of flavins, much like they would in a natural biofilm, and how their redox behavior affects the biofilm development.
Capillary electrophoresis (CE) is an analytical technique that
separates analytes based on their electrophoretic mobility with
the use of an applied voltage.
Nanoparticles separation using CE exhibits good separation and
analysis efficiency, especially for nanoparticles smaller than 30
nm. The coupling of CE with inductively coupled plasma mass
spectrometry (ICP-MS) provides the possibility to detect
nanoparticles in the concentration range of nanograms per litre
and enables the simultaneous detection of nanoparticles and its
[1][2] ionic counter parts.
Our objective is to develop a fast and reliable separation method
for differently modified nanoparticles using capillary
electrophoresis.
Inhibition of Herpes Virus by Specific and Non-specific Interactions With Graphene Conjugates
(2017)
Herpes viruses (HSV) are global, host-adapted pathogens that cause a widespread diversity of diseases. The frequency of HSV infections all over the world has amplified over the last years, making it a major concern in the area of public health. Therefore, synthesis of systems that can inhibit development of these viruses is required. Various compounds already have shown inhibition of HSV, but concentration of these inhibitors is relatively high and resistance against those drugs is challenging.
Combination of biological knowledge, about structure of the active site on the surface of HSV that is responsible for inhibition of the pathogen, with the chemistry of graphene results in 2D systems with the ability of specific and nonspecific interactions with HSV. In this work, 2D nanomaterials with picomolar IC50 against HSV are synthesized by conjugation of peptides to the surface of graphene.
2D nanomaterials are characterized by various methods, including XPS, AFM and IR. Biological evaluation showed high potency of synthesized nanomaterials to inhibit HSV and therefore underlined possibility to use such materials in future biomedical applications.
Graphene and its derivatives have recently attracted much attention for sensing and deactivating pathogens. However, mechanism of multivalent interactions at the graphene-pathogen interface are not fully understood. Since different physicochemical parameters of graphene play a role at this interface, control over graphene’s structure is necessary to study the mechanism of these interactions. In this work, zwitterionic graphene nanomaterials (ZGNMs) were synthesized with defined isoelectric points and exposure, in terms of polymer coverage and functionality. Then, the switchable interactions of ZGNMs with E. coli were investigated to study the validity of the generally proposed “trapping” mechanism for inactivating pathogens by functionalized graphene derivatives. The ZGNMs were able to controllably trap and release E. coli by crossing their isoelectric points.
Metal organic frameworks and coordination polymers play an important role in different fields of applications. Moreover, particularly fluorinated metal-organic frameworks (FMOFs) are in the focus of interest during the last years. In most cases, fluorine is implemented using perfluorinated organic linkers at the synthesis, usually performed by solvothermal synthesis. However, only few examples are known so far where fluorine is coordinated directly to the metal cation. Recently, we reported about mechanochemical syntheses and characterization of fluorine-containing coordination polymers of alkaline earth metals by milling M(OH) (M: Ca, Sr, Ba) with fluorinated benzene dicarboxylic acids 2 and we reported about mechanochemical syntheses of alkaline earth metal fluorides with ammonium fluoride. Now we are reporting about a combination of both synthesis routes. That is the first mechanochemical synthesis of coordination polymers where fluorine is coordinated directly to the metal cation.
The Cairo Geniza is an “archive” discovered in the 19th century in Ben Ezra Synagogue in Fustat, a district in Old Cairo (Egypt), located south of the center of modern Cairo. The giant collection of mostly Jewish documents that vary in genres, languages and writing supports contains a large number of early medieval Hebrew manuscripts, mostly in fragmentary form. The larger part of the Cairo Geniza is stored today in the Cambridge University Library.
The Geniza provides sources for the literary, linguistic, historical studies of the various aspects Jewish life. As the documents attest, at least two Jewish communities co-existed in Fustat up to 11th century: a so-called Babylonian and Palestinian. These communities had different leaders, different traditions and lived independently. The differences seem to manifest themselves also in the paleographical, codicological and some material properties of the manuscripts produced by each community.
My work addresses the ink composition in the documents attributed to the members of these communities. For the determination of the inks type and composition I employ reflectography and µ-XRF spectrometry, respectively. The preliminary typological studies indicate that iron-gall inks were found predominantly in the manuscripts attributed to the Palestinian community.
Accurate measurements of stable isotope abundance ratio variations are often reported using artifact based delta-scales, which rely on suitable isotopic reference materials (iRM) for their realization. For example, variations in the 26Mg/24Mg isotope abundance ratio in natural systems are typically reported as delta26Mg values that represents the relative difference between the 26Mg/24Mg ratio measured in a sample relative to its measurement preferably in an iRM. In the past, such delta26Mg measurements were referenced to NIST SRM 980, the initial zero of the delta26Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. It was then replaced by a Mg solution (DSM3), the new zero of the delta26Mg scale. A potential replacement iRM for DSM3 has been developed, ERM-AE143. This iRM has also been measured for its absolute isotope amount ratios1,2 making it traceable to the SI.
The results of an delta26Mg intercomparison experiment include the Mg iRMs SRM 980, IRMM-009, ERM-AE143, AE144, AE145 standards DSM3 and Cambridge-1. The intercomparison involved 5 expert laboratories, consisting of 3 national metrological institutes (BAM, NIST, PTB) and 2 scientific research laboratories (GFZ Potsdam, UBremen).
The iRMs were measured relative to AE143 and cover a range of ≈5 ‰ in delta26Mg. IRMM-009 has the lowest delta26Mg value while DSM3 has the highest, spanning a range in values that covers natural Mg isotope variations. The 2SD reproducibilities of the individual values from the different laboratories range from 0.02 to 0.26 ‰. The mean delta26Mg values, calculated from the laboratory means however show 2SD reproducibilities varing between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for delta26Mg determinations.
Hepcidin-25 has attracted much attention ever since its discovery in 2001. It is widely recognized that this liver produced peptide hormone plays a major role in the regulation of iron levels in mammals and can reveal important clinical information about several pathological states in patients suffering from iron-related disorders.
With the aim to tackle the current difficulties in hepcidin quantification and improve the status of this promising biomarker in the clinical field, we developed a rapid and robust analytical strategy for the quantification of hepcidin-25 in human samples based on HPLC-MS/MS (QqQ) to be implemented in routine laboratories. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyl-dimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no significant losses in the dynamic range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Careful analytical validation was performed for determining the reproducibility, repeatability, limit of quantification (0.5 µg/L) and linearity (0.5-40 µg/L) of the method. Serum samples from 9 healthy volunteers were analyzed with a median hepcidin-25 level of 3.3 µg/L, comparable to results reported in the literature.
We developed a rapid and robust HPLC-MS/MS (QqQ) method for the quantification of hepcidin-25, a promising new biomarker in iron metabolism, in human samples. The novelty of the method is the use of special HPLC vials to avoid adsorptive losses due to the basic character of the peptide that causes interaction with the silanol groups of the vial’s glass surface. Up to 90% decrease in the MS/MS signal was observed, when commercial HPLC vials were used, while vials treated with 3-(2-aminoethylamino)propylmethyldimethoxysilane or 1H,1H,2H,2H-perfluorooctyltriethoxysilane, leading to no losses in the range of physiological hepcidin-25 mean serum levels (10-20 µg/L).
Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.
Mechanaochemistry is an effective method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
Mechanaochemistry is an effective method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of
mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
Mechanaochemistry is an effective method to yield pure compounds within a short reaction time. Mechanochemical C-C bond forming reactions gained increasing interest in the past decade. Among those the Knoevenagel condensation is an important reaction for synthezing a,b-unsaturated compounds. The information on the underlying mechanisms of mechanochemical reactions are scarce. In situ investigations using Raman spectroscopy and synchroton XRD either alone or in combination address this challenge. We present the in situ results of a Knoevenagel condensation with p-nitrobenzaldehyde and malononitrile under neat grinding conditions.
The EC recommendation for the definition of nanomaterial [2011/696/EU] requires the quantitative size determination of constituent particles in samples down to 1 nm. Accordingly, a material is a nanomaterial if 50 % or more of the particles are in the size range 1-100 nm. The fact that engineered nanomaterials already exist in many industrial and consumer products challenges the development of measurement methods to reliably identify, characterize and quantify their occurrence as substance and in various matrices.
The EU FP7 NanoDefine project [www.nanodefine.eu] has addressed this challenge by developing a robust, readily implementable and cost-effective measurement strategy to obtain quantitative particle size distributions and to distinguish between nano and non-nano materials according to the EU definition. Based on a comprehensive evaluation of existing methodologies and intra- and inter-lab comparisons, validated measurement methods and instrument calibration procedures have been established to reliably measure the size of particles within 1-100 nm, and beyond, including different shapes, coatings and chemical compositions in industrial materials and consumer products. Case studies prove their applicability for various sectors, including food, pigments and cosmetics.
Main outcome is the establishment of an integrated tiered approach including rapid screening (tier 1) and confirmatory methods (tier 2), and a user manual to guide end-users, such as manufacturers, in selecting appropriate methods. Another main product is the “NanoDefiner” e-Tool allowing the standardised / semi-automated selection of appropriate methods for material classification according to the EU definition. Results also contribute to standardization efforts, such as CEN TC 352 or ISO TC 229.
Accurate measurements of stable isotope abundance ratio variations are often reported using artifact based delta-scales, which rely on suitable isotopic reference materials (iRM) for their realization. For example, variations in the 26Mg/24Mg isotope abundance ratio in natural systems are typically reported as delta26Mg values that represents the relative difference between the 26Mg/24Mg ratio measured in a sample relative to its measurement preferably in an iRM. In the past, such delta26Mg measurements were referenced to NIST SRM 980, the initial zero of the delta26Mg scale. With the development of MC-ICPMS, the detection of small but measurable isotopic differences in different chips of SRM 980 became apparent. It was then replaced by a Mg solution (DSM3), the new zero of the delta26Mg scale. A potential replacement iRM for DSM3 has been developed, ERM-AE143. This iRM has also been measured for its absolute isotope amount ratios1,2 making it traceable to the SI.
The results of an delta26Mg intercomparison experiment include the Mg iRMs SRM 980, IRMM-009, ERM-AE143, AE144, AE145 standards DSM3 and Cambridge-1. The intercomparison involved 5 expert laboratories, consisting of 3 national metrological institutes (BAM, NIST, PTB) and 2 scientific research laboratories (GFZ Potsdam, UBremen).
The iRMs were measured relative to AE143 and cover a range of ≈5 ‰ in delta26Mg. IRMM-009 has the lowest delta26Mg value while DSM3 has the highest, spanning a range in values that covers natural Mg isotope variations. The 2SD reproducibilities of the individual values from the different laboratories range from 0.02 to 0.26 ‰. The mean delta26Mg values, calculated from the laboratory means however show 2SD reproducibilities varing between 0.025 and 0.093 ‰. Propagated measurement uncertainties suggest a standard uncertainty of about 0.1‰ for delta26Mg determinations.
1 JAAS, 2015, 31,179; 2JAAS, 2016, 31, 1440
Scanning Electron Microscopy (SEM) or Transmission Electron Microscopy (TEM) ? This is a question, nowadays discussed in EM labs of research and industry involved in the characterization and metrology of nanoparticles. The Scanning principle is adapted to TEM, the Transmission mode is adapted to Ultra High Resolution SEM. Can modern SEM replace TEM, reach atomic resolution even without Cs corrector or nm lateral resolution for energydispersive X-ray spectroscopy (EDX)?
Due to the development of a New Cold Field Emission (NCFE) electron source Hitachi SEMs SU9000 and SU8200 can deliver routinely sub-nm image resolution and EDX mappings at very high count rates and a lateral EDX resolution of a few nm. A TiO2 sample provided by BAM was analysed at 30kV using low kV STEM – simultaneously with the Through-the-lens (TTL) SE detector, the Bright Field transmitted and Dark Field transmitted signals. By this method a pixel precise information of the particles surface using SE, its chemical nature using DF-STEM and its crystalline structure using Bright Field signal is given in one 40sec scan. The advantage of this observation mode compared to Ultra Low Voltage imaging is outlined.
The development of low carbon cements has gained great importance over the last decades. In the effort to limit the carbon content related to its production, cement is often replaced with supplementary cementitious materials (SCMs). Commonly used SCMs such as fly ash and slag have undergone extensive research, but are currently limited in supply and availability. Among the researched SCMs, calcined clays have proven to be a suitable alternative pozzolan due to their worldwide availability and extremely low calcination temperatures when compared to clinker. This poster presents the results from an ongoing project, aimed at obtaining pozzolans, available in sufficient quantities for Portland-pozzolana cement production in Germany. The poster shows the analyses of seven brick clays from various deposits in central Germany. The chemical and mineral composition of the brick clays was evaluated through inductively coupled plasma – optical emission spectroscopy (ICP-OES), X-ray diffraction (XRD), and thermogravimetric analysis (TG/DTG). The particle size distribution (PSD) was also evaluated by laser granulometry. The results show that the brick clays contain a substantial amount of kaolinite, illite and smectite minerals, the relative proportions differing significantly between deposits. The suitable calcination temperature range of the clays is also evaluated through TG/DTG analysis to obtain the optimum degree of dehydroxylation from which the bricks clays can be suitable for use as a pozzolan.
A multilayer consisting of two different rotaxanes was investigated with different analytical methods. The rotaxanes can be switched with two different stimuli - chemical and photochemical. XPS indicates that our layer-by-layer approach worked and a layer growth with every deposition step is present. NEXAFS showed that both stimuli cause an increase of the multilayer's preferential orientation.
Process analytical techniques are extremely useful tools for chemical production and manufacture and are of particular interest to the pharmaceutical, food and (petro-) chemical industries.
Today, mainly optical online methods are applied. NMR spectroscopy has a high potential for direct loop process control. Compact NMR instruments based on permanent magnets are robust and relatively inexpensive analysers, which feature advantages like low cost, low maintenance, ease of use, and cryogen-free operation. Instruments for online NMR measurements equipped with a flow-through cell, possessing a good signal-to-noise-ratio, sufficient robustness, and meeting the requirements for integration into industrial plants (i.e., explosion safety and fully automated data analysis) are currently not available off the rack.
A major advantage of NMR spectroscopy is that the method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method which is independent of the matrix. This is an important prerequisite for robust data evaluation strategies within a control concept and reduces the need for extensive maintenance of the evaluation model over the time of operation. Additionally, NMR spectroscopy provides orthogonal, but complimentary physical information to conventional, e.g., optical spectroscopy. It increases the accessible information for technical processes, where aromatic-to-aliphatic conversions or isomerizations occur and conventional methods fail due to only minor changes in functional groups.
As a technically relevant example, the catalytic hydrogenation of 2-butyne-1,4-diol and further pharmaceutical reactions were studied using an online NMR sensor based on a commercially available low-field NMR spectrometer within the framework of the EU project CONSENS (Integrated Control and Sensing).
Mechanochemistry is increasingly used for synthesizing soft matter materials including metal organic compounds and cocrystals. The ever-increasing interest in this method is contrasted by a limited mechanistic understanding of the mechanochemical reactivity and selectivity. Time-resolved in situ investigations of milling reactions provide direct insights in the underlying mechanisms. We recently introduced a setup enabling in situ investigation of mechanochemical reactions using synchrotron XRD combined with Raman spectroscopy. The specific combination allows to study milling processes comprehensively on the level of the molecular and crystalline structure and thus obtaining reliable data for mechanistic studies. In situ Raman spectroscopy coupled with thermography revealed a low temperature increase during milling reactions due to the mechanical impact and clear temperature increases because of the reaction heat.
Based on the data, temperature rises as postulated in the magma plasma and hot spot theory can be excluded for soft matter milling syntheses. Our results indicate that in situ investigation of milling reactions offer a new approach to tune and optimize mechanochemically synthesized compounds.
In this study, series of coatings with the goal of sensitising gold SPR sensors towards CO, NH4, etc. were prepared. To better understand the mechanism behind the sensitizing effect and to enable the targeted production of optimized layers, the wide range of coatings was studied by multiple methods from spectroscopic ellipsometry for their dielectric function, by XPS for chemical composition and SEM, TEM to determine their microscopic structure. The coatings were deposited at inert Ar gas and reactive Ar/O2 gas mixture by RF magnetron sputtering or DC pulsed magnetron sputtering with settable RF bias on the substrates. The plasma processes were monitors by mass spectrometry.
The metal oxide coatings in SPR sensors have to be prepared reproducible with thickness about 5 nm therefore lower deposition rate conditions were advantages.
Ever since increasing a reaction’s yield while shortening the reaction time is the main objective in synthesis optimization. Microwave reactors meet these demands. In literature however their usage is under discussion due to claims of the existence of non-thermal effects resulting from the microwave radiation. Especially for nano-material syntheses it is of crucial importance to be aware of influences on the reaction pathway. Therefore, we compare ultra-small silver nanoparticles with mean radii of 3 nm, synthesized via conventional and microwave heating. We employed a versatile one-pot polyol synthesis of poly(acrylic acid) (PAA) stabilized silver nanoparticles, which display superior catalytic properties. No microwave specific effects in terms of particle size distribution characteristics, as derived by small-angle X-ray scattering (SAXS) and dynamic light scattering (DLS), are revealed. Due to the microwave reactor’s characteristics of a closed system, syntheses can be carried out at temperatures beyond the solvent’s boiling point. Particle formation was accelerated by a factor of 30 by increasing the reaction temperature from 200 °C to 250 °C. The particle growth process follows a cluster coalescence mechanism. A post-synthetic incubation step at 250 °C induces a further growth of the particles while the size distribution broadens. Thus, utilization of microwave reactors enables an enormous decrease of the reaction time as well as the opportunity of tuning the particles’ size. Possibly, decomposition of the stabilizing ligand at elevated temperatures results in reduced yields. A temperature of 250 °C and a corresponding reaction time of 30 s represent a compromise between short reaction times and high yields.
Silver nanoparticles are one of the most widespread consumer related nanoparticles worldwide. Since the particles show special optical and antibacterial properties they are used for a wide range of applications from biological investigations over medical applications and catalysis. Especially the outstanding question of applicable alternatives for catalysts in diverse reactions can be addressed with the design of versatile system of small silver nanoparticles. In this study we present the synthesis and application of ultra-small silver nanoparticles with a narrow size distribution (R = 3.1 nm, σ = 0.6 nm). The particles are thoroughly characterized by small angle X-ray scattering, dynamic light scattering and UV/Vis spectroscopy. As a representative test reaction the reduction of 4-nitrophenol to 4-aminophenol was chosen. The particles show a catalytic activity of (436 ± 24) L g-1 s-1, which is two orders of magnitude higher than for other silver particles in the literature. The particles surrounding shell, composed of poly(acrylic acid), provides the particles with a good accessibility for the reactants. Since the catalytic activity strongly depends on the surrounding ligand, the particles shell can also be exchanged by other ligands enabling a tuning of the catalytic activity to a desired value. This shows the high flexibility of this system which can also be applied for other catalytic reactions.
Introduction: Laser Induced Breakdown Spectroscopy (LIBS) is an atomic emission analytical technique, wide spreading in laboratories and industries. One way to dramatically increase its analytical results is to deposit metal NPs on the sample surface, resulting in an better version called Nanoparticle Enhanced LIBS (NELIBS). In order to better know and use this technique, the evolution of the plasma has been studied with Tomography.
The recent developments of inovative compact NMR spectrometers are therefore remarkable due to their possible application in process analytical technology (PAT) in an industrial environment without high maintenance requirements. spectroscopic methods, NMR spectroscopy offers some unique features for online reaction monitoring. However, those benefits have not been exploited for PAT applications so far. Within the CONSENS Project, the challenge to adapt a commercially available benchtop NMR spectrometer to the full requirements of an automated chemical production environment was tackled successfully. was provided in an explosion proof housing and involves a compact NMR spectrometer together with an automated data acquisition and evaluation unit, flow control, as well as data communication.
For reaction monitoring using NMR instruments, in particular, after acquisition of the FID the data needs to be corrected in real-time for common effects using automated methods. When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models. Acquired raw spectra were processed with the following tools:
· Phase correction using the Entropy minimization method
· Baseline correction using a low-order Polynomial fit
· Alignment (icoshift) Pure component models based on Pseudo-Voigt functions can be derived via peak fitting of measured pure components or by the use of spin calculations.
SrF2 nanoparticles can be doped with trivalent earth metal ions such as Eu3+ and Tb3+ to generate materials exhibiting an intensive red or green fluorescence. A CaF2 shell increases intensity, fluorescence lifetie and quantum yield. The chemical composition of the nanoparticle core-shell region is investigated by XPS at different excitation energies corresponding to different information depths.
The influence of the support structure on residual stress and distortion in SLM Inconel 718 parts
(2017)
The effect of support structure and of removal from the base plate on the residual stress state in Selective Laser Melted IN718 parts was studied by means of synchrotron X-ray diffraction. The residual stresses in subsurface region of two elongated prisms in as-built condition and after the cutting from the base plate were determined. One sample was directly built on a base plate and another one on a support structure. Also, the distortion on the top surface due to stress release was measured by contact profilometry. High tensile residual stress values were found, with pronounced stress gradient along the hatching direction. In the sample on support stress redistribution took place after removal of the base plate, as opposed to simple stress relaxation for the sample without support. The sample on support structure showed larger distortion compared to sample without support. We conclude that the use of a support decreases stress values but stress relieving heat treatments are still needed.
Graphene derivatives have shown great promise in the field of pathogen binding and sensing. Due to their diverse applications, they show a variety of activities that range from bacterial adhesion to bacterial resistance. Therefore, domination of the graphene-pathogen interactions is highly relevant for producing 2D platforms with the desired applications. In order to gain control over the interactions between graphene and biosystems, mechanisms should be fully understood. The surface functionality of graphene is one of the most important factors that dominates its interactions with biosystems and pathogens. Covalent functionalization is a robust method through which functionality, chemical structure, and subsequently physicochemical properties of graphene are abundantly manipulated. A critical issue for preparing graphene-based 2D materials with a defined surface structure, however, is controlling the functionalization in terms of number, position, and type of functional groups.
Anomalous surface composition in thin films of a poly(vinyl methyl ether) / polystyrene blend
(2017)
Highly surface-sensitive X-ray photoelectron spectroscopy at HE-SGM beamline revealed in the outermost region (< 2nm) of thin films (15 -65 nm) of PVME/PS blends a relative high amount of PS, whereas in slightly deeper regions PVME was enriched. Such enrichment of PVME in the whole near-surface region was proposed in former investigations based on conventional XPS studies.
Synchrotron X-ray refraction radiography (SXRR) is proven to identify different kinds of defects in Ti-Al6-V4 samples produces by selective laser melting. Namely, these defect types are empty pores and unprocessed powder, which are characteristic to the regions above and below the optimal laser energy density, respectively. Furthermore, SXRR detects small defects below the spatial resolution.
Besides their plasticizing effect, superplasticizers (SPs) are known to retard the hydration of inorganic systems such as cement. Despite their frequent use, the understanding of these highly complex systems is still limited and the relevant parameters, which control the interaction between SPs, and cement components and reaction products are in the focus of ongoing research activities.[1] Optical methods have been successfully used for the analysis and monitoring of the interactions between a broad variety of nanoscale and molecular systems like nanoparticles of various chemical composition and different types of organic ligands or biomolecules. The potential of these methods to study processes at the interface between (hydrated) particles and the fluid phase at a very early stage of concrete formation could reveal possible mechanisms of interaction.
This investigation focuses on the study of organic/inorganic mixtures consisting of cement (CEM) and cement phases (C3S and C3A) in the presence of polycarboxylate ether and organic dyes in aqueous solution (particularly alkali resistant dyes) at a water to powder ratio of 1. Diffuse reflectance as well as steady state and time resolved fluorescence spectroscopy of the above mentioned mixtures were evaluated. Based upon changes of the intensity of the reflectance and fluorescence signal and spectral changes of the dye, acting as optical reporter, a model for the interactions of dye, PCE and cement (including different cement phases) was derived which describes the very first stage of cement hydration.
Analysis of stable isotopes has been used as proof of provenance of mineral and biological samples, to estimate a contamination source and to determine geological processes. This kind of analysis needs high accuracy and precision for reliable conclusions. Currently, stable isotope analysis is dominated by mass spectrometric techniques that are time consuming and expensive. Here we present a fast and low cost alternative for isotope analysis of boron and magnesium: high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). Two stable isotope systems were evaluated separately: boron (10B:11B) and magnesium (24Mg:25Mg:26Mg). Their isotope amount ratios were estimated by monitoring their absorption spectra in-situ generated monohydrides. The molecular absorption spectrum of a XH molecule (X= B or Mg) with n isotopes would be a linear combination of n isotopologue spectra and the amount of each component (isotope) could be calculated by a multivariate regression (n= 2 and 3 for B and Mg respectively). For the analysis of boron certified reference materials (CRM), the band 1→1 for the electronic transition X1Σ+ → A1Π was measured around wavelength 437.1 nm. Since boron has a memory effect in graphite furnaces, a combination of 2 % (v/v) hydrogen gas in argon, 1 % trifluoromethane in argon, an acid solution of calcium chloride and mannitol as chemical modifiers were used during the BH vaporization at 2600 °C. Partial least square regression (PLS) for analysis of samples was applied. For this, a spectral library with different isotope ratios for PLS regression was created. Magnesium does not have memory effect. Therefore, only 2 % of hydrogen in argon as gas modifier during vaporization at 2500 °C was employed for analysis of magnesium CRM. Absorption spectra of MgH for the X2Σ→A2Π electronic transition (band 0→0) were recorded around wavelength 513.45 nm. A similar PLS procedure to the BH was applied. Results for B and Mg CRM are metrologically compatible with those reported by mass spectrometric methods. An accuracy of 0.08 ‰ for B and 0.1 ‰ Mg was obtained as the average deviation from the isotope CRM. Expanded uncertainties with a coverage factor of k = 2 range between 0.10 - 0.40 ‰.
Pollution through emission of toxic gases is of utmost environmental concern, raising the interest in developing reliable gas sensors. Exemplarily, ammonia and its conversion products can provoke considerable damage on human health and ecosystems. Hence, there is a need for reliable and reversible sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for field measurements. Although various types of sensors such as potentiometric, amperometric, and biological sensors are available for detecting trace amounts of gases, fluorescent sensors have gained importance due to several advantages such as high sensitivity, possible miniaturization, as well as potential multiplexing. Herein, we present the development of a sensor material for gaseous ammonia in the lower ppm or even ppb range using optical fluorescence as transduction mechanism due to its intrinsically high sensitivity and high spatial resolution.[1] Therefore, a fluorescent dye, which shows reversible fluorescence enhancement in the presence of the analyte was incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. To calibrate the designed optical sensor system a gas standard generator was used, producing standard gas mixtures, which comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range.[2] Beside the development of a highly sensitive, selective, and reversible sensor, the integration of such systems into mobile sensor devices is addressed. Therefore, a prototype of a miniaturized hand-held instrument was developed enabling a straightforward and long-term read-out of the measurement signal.
Variations in the isotope amount composition of some elements like lithium, boron, magnesium, calcium, copper and strontium have been used as proof of provenance of a sample and to describe geological processes. Routinely, isotope compositions are determinate by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time consuming and they require a high qualified analysist.
Here an alternative faster and low cost optical method for isotope ratio determination is proposed: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X= Li, B, Mg, Ca, Cu and Sr have been determined by monitoring the absorption spectrum of their monohydride (XH) in graphite furnace HR-CS-MAS. For example, for the three Mg isotopes (24Mg, 25Mg and 26Mg) band (0→0) for the electronic transition X1Σ+ → A1Π was evaluated around wavelength 513.4 nm (Fig. 1). Partial least square regression (PLS) for analysis of samples and reference materials were applied. For this, a spectral library with different isotopes ratios for PLS regression were built. Results are metrological compatible with those reported by mass spectrometric methods.
Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol-1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors.
The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2).
Homogeneity of dispersed brominated flame retardants (HBCD) in polystyrene by LA-ICP-MS and XRF
(2017)
To investigate the release or migration of flame retardants from polypropylene (PP) and polysytrene (PS) samples with a defined content of flame retardants as additives were prepared and used. Therefore a distinct 1,2,5,6,9,10-hexabromocyclododecane HBCD concentration of 1 wt.% in PS resp. a specified bromodiphenylether (BDE-209) of 0.1 wt.% in PP is defined. For the preparation of the samples granular PP or PS are extruded together with the BFR additives. Even the result of this process may lead to homogenous partitions of the BFR additives. So, the distribution of these additives must be proven before using the samples in an experimental setup for weathering studies. In accordance to the regulation of RoHS (2011/65/EU) , where the use of XRF is recommended for the proof of flame retardants in electronic consumer products, we use this method as a reference to the laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Therefore we present the correlation of these experiments. The experimental setup for the XRF experiment is like a standard addition: in cavities, which are introduced in the sample plates subsequently, solutions of defined concentration of flame retardants are put in there. According to the idea of standard addition, we get an information of the originating mass fraction of flame retardant in each sample and we can monitor the release and migration of these additives during/after the weathering experiments with high precision. An internal standard of HBCD is added as a marker and can be analyzed after the weathering experiment.
Nuclear magnetic resonance (NMR) is a well established laboratory / borehole method to characterize the storage and transport properties of rocks due to its direct sensitivity to the corresponding pore fluid saturation (water or oil) and pore sizes.
For petrophysical applications there are several different NMR laboratory devices commercially available varying over a wide range of e.g. magnetic field strength / frequency (2 MHz to 30 MHz), applicable measurement protocols (T1, T2, T1-T2, T2-D, etc.) and sample sizes (2.5 cm to 10 cm in diameter). In this work we present NMR measurements, layed out in a round robin like manner, on a set of 20 sandstone samples. We use three different NMR devices containing two standard setups with homogenous magnetic fields (LIAG and RWTH) and one single-sided setup with gradient field (BGR) to measure T1 and T2 relaxation data. In our evaluation we especially focus on the comparison of the individually inverted relaxation time distributions to quantify the differences arising from different laboratory setups. Diverging results can be deduced on the one hand to the inherit differences between homogeneous and gradient fields but on the other hand also due to quality differences between the two homogeneous setups. Additionally, we also examine the influence of the individually chosen inversion parameters (signal processing, distribution sampling points, error weighting, regularization, etc.) to establish a general standardized best practice recommendation for future petrophysical NMR laboratory measurements.
Today, 40 % of the world’s population live in areas with a significant risk of dengue infection. Early and reliable diagnosis of dengue virus (DENV) is essential to provide the patients with the required medical care and prevent spreading of the disease. Conventional methods for DENV diagnosis like PCR and virus isolation can be used in laboratory settings, yet are difficult to implement in point-of-care diagnostics, requiring simple, selective, fast, and sensitive detection schemes. We present here a novel approach for the detection of DENV, via its RNA, with optical read-out that relies on RNA-catalyzed fluorophore transfer onto a semiconductor quantum dot (QD) and Förster resonance energy transfer (FRET).
For this RNA assay, peptide nucleic acid (PNA) oligomers were used as highly specific capture and reporter probes. PNA exhibits remarkable affinity towards RNA as well as extremely high chemical and enzymatic stability. The capture probe, which is immobilized on a QD acting as FRET donor, bears a nucleophile at the N-terminus and the reporter probe is modified with an organic dye acting as FRET acceptor. The presence of DENV genomic RNA in the sample triggers a transfer of the dye onto the QD, signaled by FRET between the QD and the dye. A unique advantage of this system is the ability of one RNA molecule to trigger multiple transfer reactions, thereby amplifying the fluorescence signal. This assay together with the exceptional brightness of QDs and outstanding hybridization properties of PNA allows for highly specific and sensitive detection of DENV RNA in the sub-nM range.
Polymer nanoparticles (NPs) are of increasing importance for a wide range of applications in the material and life sciences. This includes their use as carriers for dye molecules and drugs, multichromophoric reporters for signal enhancement strategies in optical assays, targeted probes in bioimaging studies, and nanosensors.[1] Application-relevant properties of such NPs include their size, morphology, colloidal stability, and ease of surface functionalization with e.g., sensor molecules and targeting ligands. Many of these features as well as the interaction of NPs with their microenvironment are closely linked to the knowledge of the chemical nature and total number of surface groups as well as the number of surface functionalities accessible for subsequent coupling reactions of differently sized ligands, biomolecules or reporter molecules. This underlines the importance of simple, robust, reliable, and validated methods, which can be employed for the characterization of a broad variety of particle systems independent of their optical properties, i.e., scattering or the presence of encoding dyes.[2]
In this respect, we assessed a variety of conventional and newly developed colorimetric or fluorometric labels for the optical surface group analysis, utilizing e.g., changes in intensity and/or color for signal generation.[3] Moreover, novel cleavable and multimodal reporters were developed which consist of a reactive group, a cleavable linker, and an optically active moiety, chosen to contain also heteroatoms for straightforward method validation by elemental analysis, ICP-OES, ICP-MS or NMR. In contrast to conventional labels measured bound at the particle surface, which can favor signal distortions by scattering and encoding dyes, cleavable reporters can be detected colorimetrically or fluorometrically both attached at the particle surface and after quantitative cleavage of the linker in the transparent supernatant after particle removal e.g., by centrifugation. Here, we present first results obtained for the optical quantification of carboxylic and amino groups on a series of self-made NPs with different types of labels and compare their potential and drawbacks for surface group analysis.
Fluorescence based sensing is a versatile approach for the trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them a superior active component for the preparation of optical sensor devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary approach presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable.
The dyes presented follow a “turn-on” fluorescence schematic which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which are calibration intensive. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environments for advanced process monitoring and control.
Within the European Union’s Research Project CONSENS (Integrated CONtrol and SENsing, www.consens-spire.eu) by development and integration of a smart NMR module for process monitoring was designed and delivers online spectra of various reactions. The presented NMR module is provided in an explosion proof housing of 57 x 57 x 85 cm module size and involves a compact spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction), and evaluation.
For reaction monitoring and process control using NMR instruments after acquisition of the FID the data needs to be corrected in real-time for common effects using fast interfaces and automated methods.
When it comes to NMR data evaluation under industrial process conditions, the shape of signals can change drastically due to nonlinear effects. Additionally, the multiplet structure becomes more dominant because of the comparably low-field strengths which results in overlapping of multiple signals. However, the structural and quantitative information is still present but needs to be extracted by applying predictive models.
We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants, or derivatives and robust automation schemes.
Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions.
Innovation is the catalyst for the technology of the future. It is important to develop new and better technologies that can continuously monitor the environmental impact, e.g., for air quality control or emission detection. In the recently at BAM developed Universal Pump Sensor Control (UPSC3) module, different components and sensors are fused. The combination of the individual components makes the UPSC3 module an excellent monitoring and reference system for the development and characterization of gas specific sensors. Measurements over long periods are possible, for mixed gas loads or for certain gas measurements. The system is part of a mobile sensor network of several sensor units, which can also be used as standalone systems.
The motivation and objective of this research is to develop gas sensors based on fluorescence detection with range of ppm / ppb. For this task a reference system is required, which contains volatile organic compound (VOC) sensors for reference data from different scenarios. The integrated multi-sensor unit can measure different gases through the integrated 3-fold VOC sensor, which can be adapted to the addressed scenario. . The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrated memory card. If the previously determined limit range is exceeded, an alarm is generated. The system is an important tool towards further developments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors.
Laser ablation with inductively coupled plasma is still more used in life science as biology and biomedicine and the utilization of metals and proteins determination simultaneously is also growing up. We have developed a new strategy of labeling of antibody (it can specific binds to proteins) by nanoparticles and quantum dots which is composed of thousands of atoms and thus increases the sensitivity enormously and of course decreases the Limit of detection, compare to lanthanoids labeling. The ability of successfully tagged antibodies bound to Antigen (protein) was proved by dot blot on membrane imaged by LA-ICP-MS.
LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. In the last few years there has been a growing interest in applications of LIBS in the field of agriculture. As part of the National Research Strategy BioEconomy 2030 the German Federal Ministry of Education and Research (BMBF) started an innovation programme called BonaRes. BonaRes consists of ten interdisciplinary research project associations which are dealing with soil as a sustainable resource for the bio-economy. One of these research projects is I4S (intelligence for soil) which has the goal to develop an integrated system for site-specific soil fertility management. This system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated. When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. With the help of 16 certified reference soils, calibration curves for different elements were initially calculated and used for the quantification of seven soil samples from different testing grounds in Germany. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, a calibration curve based on multivariate analysis (partial least square regression) was generated.