Analytische Chemie
Filtern
Dokumenttyp
- Vortrag (148)
- Zeitschriftenartikel (71)
- Beitrag zu einem Tagungsband (57)
- Posterpräsentation (37)
- Sonstiges (9)
- Dissertation (3)
- Buchkapitel (2)
- Tagungsband (Herausgeberschaft für den kompletten Band) (2)
- Forschungsdatensatz (1)
Sprache
- Englisch (221)
- Deutsch (106)
- Russisch (2)
- Mehrsprachig (1)
Schlagworte
- Thermography (51)
- NDT (40)
- Super resolution (34)
- Zerstörungsfreie Prüfung (24)
- Thermografie (22)
- Laser thermography (21)
- Human Factors (19)
- Non-destructive testing (18)
- LIBS (16)
- NMR (14)
Organisationseinheit der BAM
- 8.0 Abteilungsleitung und andere (330) (entfernen)
Paper des Monats
- ja (3)
Eingeladener Vortrag
- nein (148)
An observation of the fracture process in front of the crack tip inside a dentin sample by means of ex-situ X-ray computed tomography after uniaxial compression at different deformation values was carried out in this work. This ex-situ approach allowed the microstructure and fracturing process of human dentin to be observed during loading. No cracks are observed up to the middle part of the irreversible deformation in the samples at least visible at 0.4μm resolution. First cracks appeared before the mechanical stress reached the compression strength. The growth of the cracks is realized by connecting the main cracks with satellite cracks that lie ahead of the main crack tip and parallel its trajectory. When under the stress load the deformation in the sample exceeds the deformation at the compression strength of dentin, an appearance of micro-cracks in front of the main cracks is observed. The micro-cracks are inclined (~60°) to the trajectory of the main cracks. The further growth of the main cracks is not realized due to the junction with the micro-cracks; we assume that the micro-cracks dissipate the energy of the main crack and suppressed its growth. These micro-cracks serve as additional stress accommodations, therefore the samples do not break apart after the compression test, as it is usually observed under bending and tension tests.
A semi-automatic thermographic procedure for the assessment of the welded area of resistance projection welded joints has been developed. Currently, to assess the quality of RPW joints destructive tests are used and the more commonly used non-destructive technique is the ultrasonic one. The possibility for a quantitative evaluation of the welded area by thermographic technique has been proved by means of an innovative procedure applied on steel RPW joints with ‘as it’ surface conditions. Measurements obtained by thermography and ultrasound have been compared, to verify the developed procedure.
In this work, the thermal properties of ternary Li₃ₓCo₇₋₄ₓSb₂₊ₓO₁₂ solid solutions are studied for different concentrations in the range 0 ≤ x ≤ 0.7. Samples are elaborated at four different sintering temperatures: 1100, 1150, 1200 and 1250 °C. The effect of increasing the content of Li⁺ and Sb⁵⁺, accompanied by the reduction of Co²⁺, on the thermal properties is studied. It is shown that a thermal diffusivity gap, which is more pronounced for low values of x, can be triggered at a certain threshold sintering temperature (around 1150 °C in this study). This effect is explained by the increase of contact area between adjacent grains. Nevertheless, this effect is found to be less pronounced in the thermal conductivity. Moreover, a new framework for heat diffusion in solids is presented that establishes that both the heat flux and the thermal energy (or heat) satisfy a diffusion equation and therefore highlights the importance of thermal diffusivity in transient heat conduction phenomena.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden.
To evaluate the durability of new alternative cement compositions, it is important to examine the internal transport of moisture through these materials. For this purpose, mortars were prepared from different types of cement and capillary suction experiments were carried out. The moisture transport was studied with an NMR tomograph and compared with weight measurements. With the tomograph, the total moisture input could be determined, as well as the moisture content within the samples non-destructively and spatially resolved. This allows precise observation of the moisture fronts. The tomograph was also used to determine the capillary transport coefficient.
Laser powder bed fusion is one of the most promising additive manufacturing techniques for printing complex-shaped metal components. However, the formation of subsurface porosity poses a significant risk to the service lifetime of the printed parts. In-situ monitoring offers the possibility to detect porosity already during manufacturing. Thereby, process feedback control or a manual process interruption to cut financial losses is enabled.
Short-wave infrared thermography can monitor the thermal history of manufactured parts which is closely connected to the probability of porosity formation. Artificial intelligence methods are increasingly used for porosity prediction from the obtained large amounts of complex monitoring data. In this study, we aim to identify the potential and the challenges of deep-learning-assisted porosity prediction based on thermographic in-situ monitoring.
Therefore, the porosity prediction task is studied in detail using an exemplary dataset from the manufacturing of two Haynes282 cuboid components. Our trained 1D convolutional neural network model shows high performance (R2 score of 0.90) for the prediction of local porosity in discrete sub-volumes with dimensions of (700 x 700 x 40) μm³.
It could be demonstrated that the regressor correctly predicts layer-wise porosity changes but presumably has limited capability to predict differences in local porosity. Furthermore, there is a need to study the significance of the used thermogram feature inputs to streamline the model and to adjust the monitoring hardware. Moreover, we identified multiple sources of data uncertainty resulting from the in-situ monitoring setup, the registration with the ground truth X-ray-computed tomography data and the used pre-processing workflow that might influence the model’s performance detrimentally.
In the event of moisture deterioration, rapid detection and localization is particularly important to prevent further deterioration and costs. For building floors, the layered structure poses a challenging obstacle for most moisture measurement methods. But especially here, layer-specific information on the depth of the water is crucial for efficient and effective repairs. Ground Penetrating Radar (GPR) shows the potential to generate such depth information. Therefore, the present work investigates the suitability of GPR in combination with machine learning methods for the automated classification of the typical deterioration cases (i) dry, (ii) wet insulation, and (iii) wet screed.
First, a literature review was conducted to identify the most common methods for detecting moisture in building materials using GPR. Here, it especially became clear that all publications only investigated individual time-, amplitude- or frequency features separately, without combining them. This was seen as a potential aspect for innovation, as the multivariate application of several signal features can help to overcome individual weaknesses and limitations.
Preliminary investigations carried out on drying screed samples confirmed the profitable use of multivariate evaluations. In addition to the general suitability and dependencies of various features, first limitations due to possible interference between the direct wave and the reflection wave could be identified. This is particularly evident with thin or dry materials, for which the two-way travel times of the reflected radar signals become shorter.
An extensive laboratory experiment was carried out, for which a modular test specimen was designed to enable the variation of the material type and thickness of screed and insulation, as well as the simulation of moisture deteriorations. The data collected revealed clear differences between dry and deteriored structures within measured B-scans. These deviations were to be detected with the newly introduced B-scan features, which evaluate the statistical deviation of A-scan features within a survey line. In this way, deteriorations to unknown floor structures are recognized, regardless of the material parameters present. In a subsequent training and cross-validation process of different classifiers, accuracies of over 88 \% of the 504 recorded measurements (252 different experimental setups) were achieved. For that, the combination of amplitude and frequency features, which covered all relevant reflections of the radar signals, was particularly beneficial. Furthermore, the data set showed only small differences between dry floors and deteriored screeds for the B-scan features, which could be attributed to a homogeneous distribution of the added water in the screeds. The successfully separation of these similar feature distributions raised the suspicion of overfitting, which was examined in more detail by means of a validation with on-site data.
For this purpose, investigations were carried out at five different locations in Germany, using the identical measurement method like in the laboratory. By extracting drilling cores, it was possible to determine the deterioration case for each measurement point and thus generate a corresponding reference. However, numerous data had to be sorted out before classification, since disturbances due to underfloor heating, screed reinforcements, steel beams or missing insulation prevented comparability with the laboratory experiments. Validation of the remaining data (72 B-scans) achieved only low accuracy with 53 \% correctly classified deterioration cases. Here, the previously suspected overfitting of the small decision boundary between dry setups and deteriored screeds within the laboratory proved to be a problem. The generally larger deviations within (also dry) on-site B-scans were thus frequently misclassified as screed deterioration. In addition, there were sometimes strongly varying layer thicknesses or changing cases of deterioration within a survey line, which caused additional errors due to the local limitation of the drilling core reference. Nevertheless, individual on-site examples also showed the promising potential of the applied signal features and the GPR method in general, which partly allowed a profound interpretation of the measurements. However, this interpretation still requires the experience of trained personnel and could not be automated using machine learning with the available database. Nevertheless, such experience and knowledge can be enriched by the findings of this work, which provide the basis for further research.
Future work should aim at building an open GPR data base of on-site moisture measurements on floors to provide a meaningful basis for applying machine learning. Here, referencing is a crucial point, whose limitations with respect to the moisture present and its distribution can easily reduce the potential of such efforts. The combination of several reference methods might help to overcome such limitations. Similarly, a focus on monitoring approaches can also help to reduce numerous unknown variables in moisture measurements and increase confidence in the detection of different deterioration cases.
In this paper, we demonstrate the value of 1H NMR relaxometry for studying the hydration of clinker-reduced, more climate-friendly cementitious binders. The results were obtained on typical CEM I cements and sister samples containing two different reactive agricultural ashes as well as non-reactive biochars as supplementary cementitious materials. The findings prove that time-resolved NMR measurements provide valuable additional information when combined with classical heat flow calorimetry.
Laser-based active thermography is a contactless non-destructive testing method to detect material defects by heating the object and measuring its temperature increase with an infrared camera. Systematic deviations from predicted behavior provide insight into the inner structure of the object. However, its resolution in resolving internal structures is limited due to the diffusive nature of heat diffusion. Thermographic super resolution (SR) methods aim to overcome this limitation by combining multiple thermographic measurements and mathematical optimization algorithms to improve the defect reconstruction.
Thermographic SR reconstruction methods involve measuring the temperature change in an object under test (OuT) heated with multiple different spatially structured illuminations. Subsequently, these measurements are inputted into a severely ill-posed and heavily regularized inverse problem, producing a sparse map of the OuT’s internal defect structure. Solving this inverse problem relies on limited priors, such as defect-sparsity, and iterative numerical minimization techniques. Previously mostly experimentally limited to one-dimensional regions of interest (ROIs), this thesis aims to extend the method to the reconstruction of two-dimensionalROIs with arbitrary defect distributions while maintaining reasonable experimental complexity. Ultimately, the goal of this thesis is to make the method suitable for a technology transfer to industrial applications by advancing its technology readiness level (TRL).
In order to achieve the aforementioned goal, this thesis discusses the numerical expansion of a thermographic SR reconstruction method and introduces two novel algorithms to invert the underlying inverse problem. Furthermore, a forward solution to the inverse problem in terms of the applied SR reconstruction model is set up. In conjunction with an additionally proposed algorithm for the automated determination of a set of (optimal) regularization parameters, both create the possibility to conduct analytical simulations to characterize the influence of the experimental parameters on the achievable reconstruction quality. On the experimental side, the method is upgraded to deal with two-dimensional ROIs, and multiple measurement campaigns are performed to validate the proposed inversion algorithms, forward solution and two exemplary analytical studies. For the experimental implementation of the method, the use of a laser-coupled DLP-projector is introduced, which allows projecting binary pixel
patterns that cover the whole ROI, reducing the number of necessary measurements per ROI significantly (up to 20x).
Finally, the achieved reconstruction of the internal defect structure of a purpose-made OuT is qualitatively and qualitatively benchmarked against well-established thermographic testing methods based on homogeneous illumination of the ROI. Here, the background-noise-free two-dimensional photothermal SR reconstruction results show to outclass all defect reconstructions by the considered reference methods.